SELF-CONTAINED BREATHING APPARATUS (CTS-IB-PPE-01)
©Chlorine Tech Services (Pty) Ltd
–
CIPC Reg # 2018/101848/07
Rev # 01/2020/10/15
P a g e
| 8
valve is flexible and swivelling, which can automatically fit head movement of the
operator.
2.8.
High Pressure Hose
A high-pressure gauge is connected with the high-pressure hose. The pressure
gauge surface is luminescent, so the pressure display can be viewed clearly even
in the dark. Connection of the pressure gauge and the high-pressure hose is
swivelling and can turn in 360°, this makes easy for the operator to view the pressure
gauge at any position.
There is a small hole in the high-pressure hose, which is safety hole. In case there
is leak from the high-pressure hose, air will be released from the small safety hole,
thus to avoid the high-pressure hose from exploding.
3.
USE
The device can be used only after fully maintained and tested. If malfunctions or
defects were found before using, do not use the device. Prevent the respirator
from sharp objects and prevent it from collision with any objects during the use.
The device shall be checked and repaired by MSA authorized service centre.
WARNING
3.1.
Mounting cylinder
(1) Insert the cylinder into the cylinder
strap (In this picture it only shows a
composite cylinder).
(2) Erect the cylinder and the back plate
(3) Align the cylinder valve outlet centre
with the reducer hand wheel centre.
(4) Turn the hand wheel, to connect the
reducer with the cylinder.
(5) Not to make it too tight, just hand-tight.
(6)
Don’t use any tools.
3.2.
Connecting cylinder
(1) Place compressed air breathing apparatus horizontally so that the back face
is on top.
(2) Check gasket on pressure reducer for proper condition.
(3) Open cylinder buckle on the cylinder strap eliminating any tension and
extend the strap.