background image

03

Figure 4 

Overall dimensions of NP6-J 

Figure 6

 

Installation diagram of NP6 pushbutton

2) Installation procedure and method

Before using the pushbutton, remove the plastic locking nuts and anti-

rotating ring on the pushbutton first, then insert the pushbutton in the front 
of the panel. Install the anti-rotating ring in the back of the panel. Tighten 
the  plastic  locking  nuts  so  that  the  pushbutton  is  secured  on  the  panel 
before welding the power line. 

Unit

mm

49max

Φ

24max

49max

Φ

24max

Figure 5 

Overall dimensions of NP6-ZS

Unit

mm

Summary of Contents for NP6 Series

Page 1: ...NO 2020 09 Standard IEC EN 60947 5 1 NP6 Series Pushbutton User Instruction ...

Page 2: ...n and maintenance Installation in any damp condensed phase environment with inflammable and explosive gas is forbidden When the product is being installed or maintained the power must be switched off You are prohibited from touching the conductive part when the product is operating ...

Page 3: ... Ambient temp Hot and humid atmospheric conditions Altitude Pollution class installation category Rated operating voltage Ue V Rated operating current Ie mA Rated insulation voltage Ui V Conventional thermal current Ith A Rated impulse withstand voltage Uimp kV Head protection class Technical parameters 5 40 average temperature should not exceed 35 within 24h Relative humidity should not exceed 50...

Page 4: ...enter to center distance of mounting holes should not be smaller than 25mm see Figure 1 Figure 4 for overall dimensions Figure 1 Overall dimensions of NP6 DS D BS B XD Figure 2 Overall dimensions of NP6 X Unit mm Unit mm Unit mm 40max 18max 24max 18max 18max Φ18max 46max 18max 24max 18max 18max Φ18max 58max 18max 24max 18max 18max Φ18max ...

Page 5: ...lastic locking nuts and anti rotating ring on the pushbutton first then insert the pushbutton in the front of the panel Install the anti rotating ring in the back of the panel Tighten the plastic locking nuts so that the pushbutton is secured on the panel before welding the power line Unit mm 49max Φ24max 49max Φ24max Figure 5 Overall dimensions of NP6 ZS Unit mm ...

Page 6: ...ected securely Tighten the fixing screws of the pushbutton on a regular basis Disconnect the power before regular maintenance to ensure personal safety It is recommended to conduct maintenance once a month See Table 2 for Analysis and Troubleshooting of Faults 5 Environmental Protection In order to protect the environment the product or product parts should be disposed of according to the industri...

Page 7: ...QC PASS Test date Please see the packing ZHEJIANG CHINT ELECTRICS CO LTD NP6 Series Pushbutton IEC EN 60947 5 1 Check 34 05 ...

Page 8: ...es Pushbutton User Instruction Zhejiang Chint Electrics Co Ltd Add No 1 CHINT Road CHINT Industrial Zone North Baixiang Yueqing Zhejiang 325603 P R China E mail global sales chint com Website http en chint com ...

Reviews: