background image

 

 

 

 

 

 

 

ENGLISH 

1

 

GENERAL INFORMATION 

This manual contains information for practical, correct and 
safe  use  of  the  device  and  is  intended  for  reading  by 
specialised  personnel  and  the  user  of  the  product.  It  is 
recommended that you read the entire manual carefully 
before using the product.  
If  you  have  any  doubts  or  need  clarification,  please 
contact  your  dealer  who  will  be  able  to  advise  you 
correctly. 
The  importance  of  reading  and  understanding  the  user 
manual  is  highlighted  on  the  product  by  the  following 
symbol: 
 

 

Follow the instructions for use 
 

1.1

 

Manufacturer 

CHINESPORT S.P.A, Via Croazia, 2-33100 Udine Italy 

 +39 0432621621 
 https://www.chinesport.com 
 [email protected] 

The  company  produces  in  accordance  with  the  quality 
standard UNI EN ISO 13485:2016 
 

1.2

 

LIMITATIONS OF USE AND SPECIAL WARNINGS 

The devices must not be used: 

 

Without  having  carried  out  all  the  foreseen 

adjustments and dedicated adjustments 

 

When  use  is  contraindicated  or  generates 
serious inconvenience to the patient 

 

With tampering  and  /  or  modifications  on  the 
original product 

 

In an improper configuration or when there is a 
suspicion that it may cause harm to the patient 

 

In a different way from the intended use 

 

1.3

 

SIDE EFFECTS AND CONTRAINDICATIONS 

There are no side effects. Always use the  equipment in a 
suitable  way.  Knowledge  of  this  instruction  booklet  is 
recommended. 
Before proceeding with use, it is necessary to evaluate the 
patient's psycho-physical condition. 
 

1.4

 

USERS 

Trained medical and technical staff  
 

 

It is up to the specialist to judge the physical 
fitness of the patient for whom the product is 
intended to be used.  
Use under operator supervision is always 

recommended.

 

 

1.5

 

UNPACKING 

Remove  the  aids  from  the  packaging  without  using  the 
cutter  to  avoid  damaging  them  and  properly  dispose  of 
the packaging. 
Any damage due to transport must be promptly reported 
to the carrier and to the supplier: damaged aids must not 
be used. 
 

1.6

 

ENVIRONMENT OF USE 

Clinical/hospital environment. Use on flat, dry, stable and 
obstacle-free surfaces. Not for outdoor use. 
 

1.7

 

STORING 

 

Room 

temperature 

Humidity 

Pressure 

5˚C ~ 60˚C

 

1% ~80% 

70kPa~106kPa 

 

1.8

 

MAINTENANCE 

Keep constantly clean 
 

FREQUENCY  OPERATION 

12 moths 

 
General cleaning 
Visual and functional inspection of the accessory 

 

 

1.9

 

CLEANING 

Gently dust and in case of slight stains, pass the surface with 
a damp cloth or with a solution of neutral detergent, rinsing 
with a little water. 
Dry avoiding direct exposure to sunlight. 
 

 

 
 

NEVER USE AGGRESSIVE OR ALCOHOLIC 
PRODUCTS OR DETERGENTS!  
These detergents damage plastic materials 
and screen prints, invalidating the product 
warranty

 

 

1.10

 

DISINFECTION 

For  surface  disinfection  we  recommend  the  use  of 
disinfectant  products  that  do  not  contain  alcohol, 
ammonia or other aggressive substances. 

1.11

 

ADDITIONAL INFORMATION 

Further information available on the website: 

www.chinesport.com

 

 

2

 

GENERAL WARNINGS

 

Always refer to this manual for proper use of the device. 
-

 

Store the device in an environment that complies with 
the labels on the packaging and the specifications in 
this manual. 

-

 

The  manufacturer  shall  not  be  liable,  to  the  fullest 
extent permitted by applicable law, for any direct or 

Summary of Contents for 02049

Page 1: ...OMETRO ARCOMETER CALIBRO BRACCI LUNGHI TRUNK ASYMMETRY INDICATOR TORSIOMETRO TORSIOMETER 05001 05000 02049 INDICATORE PIEDE FOOT SIZE INDICATOR ALGOGONIOMETRO ALGOGONIOMETER GONIOMETRO RETROPIEDE HINDFOOT PROTRACTOR 06730 06810 SET SPESSORI G SET OF SHIMS G FILO A PIOMBO PLUMBLINE USER AND MAINTENANCE MANUAL MANUALE D USO E MANUTENZIONE CHINESPORT SPA ITALIANO ENGLISH ...

Page 2: ...13 8 05004 TRUNK ASYMMETRY INDICATOR 15 8 1 INTENDED USE AND DESCRIPTION 15 8 2 MATERIALS 15 8 3 PACKAGE CONTENT 15 8 4 SETUP AND USE 15 9 TORSION METER 15 9 1 INTENDED USE AND DESCRIPTION 15 9 2 MATERIALS 15 9 3 PACKAGE CONTENT 15 9 4 SETUP AND USE 15 10 05001 FOOT INDICATOR 16 10 1 INTENDED USE AND DESCRIPTION 16 10 2 MATERIALS 16 10 3 PACKAGE CONTENT 16 10 4 SETUP AND USE 16 11 06810 PLUMB LINE...

Page 3: ...O 28 05004 CALIBRO BRACCI LUNGHI 30 8 1 DESTINAZIONE D USO E DESCRIZIONE DELL APPARECCHIATURA 30 8 2 MATERIALI 30 8 3 CONTENUTO DELLA CONFEZIONE 30 8 4 INSTALLAZIONE ED UTILIZZO 30 05002 TORSIOMETRO 30 9 1 DESTINAZIONE D USO E DESCRIZIONE DELL APPARECCHIATURA 30 9 2 MATERIALI 30 9 3 CONTENUTO DELLA CONFEZIONE 30 9 4 INSTALLAZIONE ED UTILIZZO 30 05001 INDICATORE PIEDE 31 10 1 DESTINAZIONE D USO E D...

Page 4: ...4 ...

Page 5: ... technical staff It is up to the specialist to judge the physical fitness of the patient for whom the product is intended to be used Use under operator supervision is always recommended 1 5 UNPACKING Remove the aids from the packaging without using the cutter to avoid damaging them and properly dispose of the packaging Any damage due to transport must be promptly reported to the carrier and to the...

Page 6: ... relevant paragraph o Incorrect maintenance or lack of maintenance o Use with parts or accessories that are not compatible or not approved by the manufacturer o Incorrect disposal or disposal is other than as described in this manual 2 1 SYMBOLS ON THE MANUAL Warning 2 2 SYMBOLS ON LABELS Follow the instructions for use CE certified Dispose of properly Manufacturer Production date Indoor use only ...

Page 7: ...e patient in the case of the spinous processes being protruding 3 2 MATERIALS Plastic PMMA 3 3 PACKAGE CONTENT Inclinometer 1pc 3 4 SETUP AND USE The device does not require installation and is ready for use Angle of trunk rotation measurement The Scoliosis Research Society defines the angle of trunk rotation as the angle between a horizontal plane and a plane crossing the most prominent point of ...

Page 8: ... 4 3 PACKAGE CONTENT Iliac Crest Analyzer 1pc 4 4 SETUP AND USE The device does not require installation and is ready for use Position the articulated arms on the patient s iliac crests so as to check their flatness using the level bubble installed on the central body In the event that the instrument highlights the presence of misalignment of the iliac crests it is generally possible to apply elev...

Page 9: ... evaluating heterometry that are available to date 1 X ray examination this represents the gold standard and is essential for programming a surgical operation in the clinicallyrelevant forms On the other hand it presents obvious limitations of use tied to radiological risk and therefore is usually not used for the more modest forms which are also the most common 2 Methods of clinical observation c...

Page 10: ...ios between the platforms Recording the difference value Considering that the right side is the reference point the difference can be expressed with a single number negative in the event the left side is shorter and positive in the even the left side is longer For example 2 heterometry means that the lower left limb is 2 cm shorter 3 means that the left limb is 3 cm longer than the right Note The ...

Page 11: ...sually arms forward in a side projection Cobb angle can be measured end vertebrae D1 D12 L1 L5 with the same procedure usually adopted for scoliosis In order to avoid excessive exposure to X rays radiographs should be taken only if strictly necessary as consequence they cannot be requested in every clinical evaluation or to verify the efficacy of a brace or the action of exercises Tecnique to buil...

Page 12: ...aspects Concordance X rays arcometer the mean difference between two series of measurements was 2 9 Cobb the concordance between the two methods of measurement was good without sistematic errors The lenght of the chord can have an influence on the results since a shorter chord bears a risk of underestimating the angle Concordance intra observator the concordance between two series of measurements ...

Page 13: ...ined crossing the values of the rise and of the chord given by the instrumen 7 7 ARCOMETER USE DEFINING DORSAL KYPHOSIS The upper and the lower limit of kyphosis are identified clinically and made visible through a dermographic pencil In order to use the measurement for comparisons through time it is wise to register not only Cobb value but also the chord length the end vertebrae of the choosen se...

Page 14: ...race fixing the lenght of the chord pay attention not to invade lordosis Second mark with a dermographic pencil the point corresponding to the hole or intermediate foot Third remove the brace and take a second measurement in standard posture without changing the lenght of the chord and using the skin mark as a reference for the intermediate foot Forth take a third measurement while making a self c...

Page 15: ... standing position 9 2 MATERIALS Plastic alluminium 9 3 PACKAGE CONTENT Torsion meter 1pc 9 4 SETUP AND USE The assessment of a subject with suspected scoliosis is carried out in a stand up position The base of the instrument is placed near the sacred in this way zero reference plane is defined with respect to which the alignment of the trunk on the transverse plane at the desired level will be re...

Page 16: ...AND USE Position the plumb line as in the image proceed with the evaluation 12 05000 ALGO GONIOMETER 12 1 INTENDED USE AND DESCRIPTION Strumento composto destinato a documentare il livello di dolore tramite scala visuale svolgere valutazioni angolari e lineari 12 2 MATERIALS PMMA 12 3 PACKAGE CONTENT Algo goniometer 1pc 12 4 SETUP AND USE The intensity of the pain is represented along a scale in w...

Page 17: ... vary in relation to age and loading methods mono or bipodalic however one can roughly indicate as a threshold of attention a valgus greater than 10 any varus value and significant asymmetries between the two sides In doubtful cases it is not so much the absolute value as the trend over time that can guide us for a physiological situation or not and for this purpose the instrument due to its ease ...

Page 18: ...rn number For products sent in their original packaging the return shipment will be made freight free For warranty repairs a fiscal document is required where the date of purchase is within the warranty period sales note purchase invoice fiscal receipt Labour costs for warranty repair when the warranty conditions are valid are borne by the manufacturer Repairing or replacing a product does not ren...

Page 19: ... D Osualdo F La valutazione del rachide attraverso l esplorazione di superficie note storiche e nuove proposte il sistema BACES Riabilitazione e Apprendimento anno 17 n 1 pp 73 85 1997 D Osualdo F Schierano S Iannis M Righini E The levelprotractor a new simple instrument to measure Cobb angle and back hump Eur Med Phys vol 36 n 5 101 106 2001 D Osualdo F Schierano S Soldano F M Isola M A new tridi...

Page 20: ...rettamente gli imballi Eventuali danni dovuti al trasporto devono essere prontamente segnalati al trasportatore e al fornitore i sussidi danneggiati non devono essere utilizzati 1 6 AMBIENTE D USO Ambiente clinico ospedaliero 1 7 IMMAGAZZINAGGIO Temperatura Ambiente Umidità Pressione 5 C 60 C 1 80 70kPa 106kPa 1 8 MANUTENZIONE Mantenere costantemente pulito FREQUENZA OPERAZIONE 12 mesi Pulizia gen...

Page 21: ...e o Errato smaltimento o smaltimento diverso da quanto previsto nel presente manuale 2 1 SIMBOLI PRESENTI NEL MANUALE Attenzione 2 2 SIMBOLI SULLE ETICHETTE Seguire le istruzioni per l uso Certificato CE Smaltire in maniera appropriata Fabbricante Data di produzione Uso solo interno 2 3 SIMBOLI PRESENTI SULL IMBALLO Fragile Reciclabile Mantenere asciutto Mantenere questo lato in alto Non utilizzar...

Page 22: ...n cui le spinose siano sporgenti 3 2 MATERIALI Materiali plastici PMMA 3 3 CONTENUTO DELLA CONFEZIONE Inclinometro 1pz 3 4 INSTALLAZIONE ED UTILIZZO Il dispositivo non necessita di installazione ed è pronto per l utilizzo La misurazione dell angolo di rotazione del tronco La Scoliosis Research Society definisce l angolo di inclinazione toracica come l angolo compreso tra un piano orizzontale e un ...

Page 23: ...eriali plastici PMMA 4 3 CONTENUTO DELLA CONFEZIONE Analizzatore creste iliache 1pz 4 4 INSTALLAZIONE ED UTILIZZO Il dispositivo non necessita di installazione ed è pronto per l utilizzo Posizionare i bracci snodati sulle creste iliache del paziente in maniera tale da verificarne la planarità mediante la livella bolla installata sul corpo centrale Nel caso in cui lo strumento evidenzi la presenza ...

Page 24: ...di valutazione della eterometria fino ad oggi disponibili 1 L esame radiografico rappresenta il gold standard ed è indispensabile per programmare un intervento chirurgico nelle forme clinicamente rilevanti Presenta peraltro delle ovvie limitazioni di impegno legate al rischio radiologico e quindi solitamente non viene impiegato nelle forme più modeste che sono anche le più comuni 2 Metodi di osser...

Page 25: ...che il destro costituisce il lato di riferimento la differenza può essere espressa con un singolo numero negativo nel caso il lato sinistro sia più corto positivo nel caso il sinistro sia più lungo esempio eterometria di 2 significa che l arto inferiore sinistro è più corto di 2 cm 3 significa che il sinistro è più lungo del destro di 3 cm Nota La rigorosa struttura dello strumento il preciso sist...

Page 26: ...osi e della lordosi è affidata all esame radiografico In una Radiografia eseguita in ortostatismo solitamente a braccia protese in proiezione latero laterale a partire dalle vertebra limite D1 D12 L1 L5 si misura l angolo di Cobb con una procedura analoga a quella utilizzata per la scoliosi Per problemi di radioprotezione le radiografie devono essere effettuate solo quando strettamente necessario ...

Page 27: ... asse Le estremità delle tre aste individuano tre punti per i quali passa una ed una sola circonferenza della quale con l arcometro si misurano due valori una corda e la relativa freccia In base a questi dati si può calcolare l angolo di Cobb ed il raggio di curvatura mediante l utilizzo di apposite tabelle a doppia entrata NB l arcometro si basa sul principio della geometria secondo il quale per ...

Page 28: ... della curva Tale valore rappresenta la corda L asta centrale viene portata nel punto medio di tale distanza e quindi viene accostata al dorso la sua scala millimetrata ci fornisce il valore della freccia Il valore dell angolo di Cobb e quello del raggio si ricavano mediante una semplice tavola a due entrate L arcometro può essere utilizzato per misurare la cifosi in diverse posture In ortostatism...

Page 29: ...cambiabile provvista di un piedino più piccolo disegnato in modo da introdursi nel foro della pelotta Per la misurazione della correzione in busto si consiglia di effettuare 3 misurazioni secondo la seguente procedura misura con busto indossato impostare la lunghezza della corda in modo tale da non sconfinare nella lordosi segnare con una matita dermografica il punto corrispondente al piedino cent...

Page 30: ...ERIALI Plastica alluminio 9 3 CONTENUTO DELLA CONFEZIONE Torsiometro 1pz 9 4 INSTALLAZIONE ED UTILIZZO La valutazione di un soggetto con sospetta scoliosi viene effettuata in posizione di attenti La base dello strumento viene accostata al sacro viene in tal modo definito un piano zero di riferimento rispetto al quale verrà letto l allineamento del tronco sul piano trasverso al livello desiderato Q...

Page 31: ...CONFEZIONE Filo a piombo 1pz 11 4 INSTALLAZIONE ED UTILIZZO Posizionare il filo a piombo come nell immagine procedere alla valutazione 05000 ALGOGONIOMETRO 12 1 DESTINAZIONE D USO E DESCRIZIONE DELL APPARECCHIATURA Strumento composto destinato a documentare il livello di dolore tramite scala visuale svolgere valutazioni angolari e lineari 12 2 MATERIALI PMMA 12 3 CONTENUTO DELLA CONFEZIONE Algogon...

Page 32: ...ssoluto dal momento che essi variano in relazione all età e alle modalità di carico mono o bipodalico tuttavia si può grossolanamente indicare come soglia di attenzione un valgismo superiore a 10 qualsiasi valore di varismo e delle significative asimmetrie tra i due lati Nei casi dubbi non è tanto il valore assoluto quanto l andamento nel tempo che ci può orientare per una situazione fisiologica o...

Page 33: ...r i prodotti inviati con l imballo originale la spedizione di ritorno sarà effettuata in porto franco Per la riparazione in garanzia occorre un documento fiscale dove la data d acquisto rientri nei tempi di garanzia bolla di vendita fattura d acquisto scontrino fiscale I costi relativi alla manodopera per la riparazione in garanzia nel momento in cui si sia accertata la validità delle condizioni d...

Page 34: ... Osualdo F La valutazione del rachide attraverso l esplorazione di superficie note storiche e nuove proposte il sistema BACES Riabilitazione e Apprendimento anno 17 n 1 pp 73 85 1997 D Osualdo F Schierano S Iannis M Righini E The levelprotractor a new simple instrument to measure Cobb angle and back hump Eur Med Phys vol 36 n 5 101 106 2001 D Osualdo F Schierano S Soldano F M Isola M A new tridime...

Page 35: ...35 ...

Page 36: ...36 ...

Reviews: