ChimneyFree 23TF10316 Manual Download Page 20

20

Troubleshooting

PROBLEM

ROOT CAUSE

CORRECTIVE ACTION

Display shows "

"

The thermostat sensor is
broken or disconnected.

Unplug the fi replace, remove the back panel 
of the fi replace and check that the thermo-
stat is plugged into the main circuit board. 
If this does not solve the problem contact 
customer service for a replacement thermo-
stat sensor.

Display shows "      "

The thermostat sensor is broken.

Contact customer service for a replacement 
thermostat sensor. 

Display shows "      "

Manual Reset overheat
protection has triggered.

Inspect the heater and check that the air 
inlets and outlets are not blocked as this may 
cause overheating. Unplug the heater for 30 
minutes and allow it to cool down. Replug 
and operate. Monitor the heater for signs of 
overheating. If the problem persist discon-
tinue use of the heater and contact customer 
service.

Display shows "      "

This is normal operation.

Check your heater cord and plug 
connections. Faulty wall outlet connections 
or loose plugs can cause the outlet or plug 
to overheat. Be sure the plug fi ts tight in the 
outlet. Heaters draw more current than small 
appliances. Overheating of the outlet may 
occur even if it has not occurred with the 
use of other appliances.  During use check 
frequently to determine if your plug outlet or 
faceplate is HOT!  If so, discontinue use of the 
heater and have a qualifi ed electrician check 
and/or replace the faulty outlet(s).

Heater does not blow warm air.

The heater is in a cool down cycle.

Normal operation will continue to run for 
several minutes before shutting down. Times 
will vary based on tempertures. During this 
time cool air will blow. 

There is no power and the logs do not 
glow.

There is no power to the unit.

Check that the unit is plugged into a 
standard 120V outlet. Press the Power button 
several times and make sure power is set to 
the “ON”position.

The logs glow, but no fl ame effect.

The fl ame effect turned off.

Press the fl ame button several times.

The heater does not blow warm air.

Thermostat setting is 
preventing the heater from 
turning on.

Adjust the temperature settings to ensure 
that the thermostat is set higher than the 
current room temperature. 

Summary of Contents for 23TF10316

Page 1: ...23TF10316 Twin Star International Inc Delray Beach FL 33445 www tsicustomerservice com 1 866 661 1218 ChimneyFree A Twin Star International Brand...

Page 2: ...sult in instability causing possible injury NOTE Flat Panel TVs with base support should be placed squarely in the center of the stand with no overhang on any side Maximum Load Warning 2 Safety Inform...

Page 3: ...the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING Under no circumstances should this fireplace be...

Page 4: ...amaged do not attempt to use or plug in the power cord until the missing or damaged part is correctly replaced To avoid electric shock use only identical replacement parts when servicing double insula...

Page 5: ...ion labor construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the manufactu...

Page 6: ...Flat Washer N A 4 NN Magnetic Catch PH MCHBRW001 2 OO Leveler Pre attached PH LVRBLK001 8 PP Drawer Slide N A 2 Sets QQ Tipping Restraint Hardware PH BKTWT003 2 ZZ Touch up Pen N A 1 NOTE Hardware no...

Page 7: ...I Decorative Front Right Panel 1 J Left Drawer 1 K Front Panel 1 L Left Side Panel 1 M Right Side Panel 1 N Right Drawer 1 O Back Panel 2 P Left Door 1 Q Right Door 1 R Wine Shelf 8 S Insert Securing...

Page 8: ...Front Base B and the Left Base A Screw the Small Bolts AA through the 3 Hole Plastic Connector JJ already connected to the Back Base Panel D Repeat to attach the Right Base C 2 Assembling the base Set...

Page 9: ...Hole Plastic Connector II to the Front Panel K Screw the Small Bolts AA through the 2 Hole Plastic Connectors II to attach the Decorative Front Left Panel H to the Center Left Side Panel E Repeat to c...

Page 10: ...anels firmly together Screw the Small Bolts AA through the 2 Hole Plastic Connectors II to the Left Side Panel L Repeat for the Right Side Panel M To secure the Front Panel K loosen pre attached Metal...

Page 11: ...n Repeat steps to attach the Right Side Panel M to the Right Base C Lay the Top Assembly G down on a flat surface On the bottom side attach the Magnetic Catch NN Using the Phillips Screwdriver insert...

Page 12: ...the Knob BB through the pre drilled holes Use the Phillips Screwdriver to tighten the screws Repeat for the Right Door Q Set the Left Door P on a flat surface Using the Phillips Screwdriver insert th...

Page 13: ...sert the Shelf Pins CC into the pre drilled holes Place the Wine Shelves R in and let rest on the Shelf Pins CC Also place the Wine Shelves R onto the bottom panel 15 17 16 Attaching the doors Prepari...

Page 14: ...Insert Securing Block S to the Center Right Side Panel F Lift the Fireplace Insert T carefully into the back of the unit and center in the fireplace insert opening 18 19 Installing the fireplace inser...

Page 15: ...e media unit Insert the 2 Hole Plastic Connector II into the pre drilled hole in the Center Left Side Panel E Screw the Small Bolt AA through the 2 Hole Plastic Connector II to the Center Right Side P...

Page 16: ...ter of the wall stud at level with the Unit Anchor and attach with two Anchor Screws using a Philips Head Screwdriver On the Anchor Tether detach the cable from the connector and loop the loose cable...

Page 17: ...and put the insert in a standby mode Push the Power button again to turn off all functions 1 2 Powering the fireplace NOTE Holding the Power button on the control panel for 10 seconds will disable th...

Page 18: ...anger the enviroment and human health This symbol marked on the battery and or packaging indicates that used battery shall not be treated as municipal waste Instead it shall be left at the appropriate...

Page 19: ...ncrease the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experien...

Page 20: ...can cause the outlet or plug to overheat Be sure the plug fits tight in the outlet Heaters draw more current than small appliances Overheating of the outlet may occur even if it has not occurred with...

Page 21: ...le times The remote control is not working There are no batteries Change the remote batteries The signal is poor Operate remote transmitter at a slow meas ured pace Press the remote control buttons wi...

Page 22: ...cement Parts Part Description Qty 1 Flame Generator Drive Motor 1 2 Emberbed Circuit Board 1 3 Blue Flame Circuit Board 1 4 Flame Circuit Board 1 5 Flame Generator Spinner 1 6 Main Circuit Board 1 7 H...

Page 23: ...Star International Inc Delray Beach FL 33445 Made in China Printed in China Fabricado en China Impreso en China Fabriqu en Chine Imprim en Chine www tsicustomerservice com 1 866 661 1218 NOTES REMARQU...

Page 24: ...24 www tsicustomerservice com ChimneyFree A Twin Star International Brand...

Reviews: