background image

 

18 

 

 
 
 
 

CHAPTER 3  
INSTALLATION 

1.

 

Installation precaution 

 

To ensure that the installation is performed correctly and the unit operates at optimum 
performance, carefully follow the instructions in this manual. Not following the instructions can 
cause the unit to malfunction and also invalidate the warranty. Chiltrix will not be responsible 
for any damage to persons, animals or property caused by improper installation or operation. 

 

It is important that the electrical installation is compliant with all NEC and local electrical codes. 

 

The appliance must be installed in a suitable position for easy access when cleaning the filter and 
general maintenance. 
 

2.

 

Installation position- Wall Mount 

The minimum distance from the floor to the lower line must be 3.25”. The minimum distance of 
the air outlet grill from any possible obstacle must be 5.5”. The minimum distance between the 
front grill and obstacles is 16”. The minimum distance between side and side wall must be at 
least 1”, to allow you to remove the cover.  

 

 

 
 
 
 

 

 

Summary of Contents for CXI120

Page 1: ...1 Chiltrix 5 1 Thin DC Inverter Water Fan Coil Unit Floor Wall or Ceiling Universal Mount Manual Version 1 4...

Page 2: ...ion 18 2 Installation Position Wall Mounts 18 3 Removing the Side Covers 19 4 Wall or Vertical Floor Mount Installation 20 5 Hydronic Installation 22 6 Condensate discharge 23 7 Ceiling Installation 2...

Page 3: ...the latest version of this manual the version number is listed on the front page o The manual includes necessary information concerning correct installation running and 1 Production Introduction Our...

Page 4: ...Template Drain Pipe Brackets Toggle Bolts Screws Screw Caps Remote Controller Inspecting and Handling the Unit After delivery the package should be checked and any damage should be reported immediate...

Page 5: ...ntrol the temperature both in summer and winter Uses a DC fan motor combined with new air guide technology makes for low noise operation Our air exchanger fin coil has a hydrophilic coating All units...

Page 6: ...zation and indication of the manufacturer It is dangerous to pull cut or knot the electrical cables coming out of the appliance even if it is disconnected from the power supply It is dangerous to poke...

Page 7: ...59 64 75 2 62 6 3135 2712 2381 2067 1778 77 64 4 3271 2830 2484 2156 1855 78 8 64 4 3376 2920 2564 2225 1914 80 6 67 1 3480 3010 2643 2294 1973 82 4 68 3615 3127 2746 2383 2050 84 2 69 8 3717 3215 28...

Page 8: ...54 59 64 75 2 62 6 52 9 56 7 60 8 64 9 69 1 77 64 4 53 3 57 0 61 1 65 1 69 3 78 8 64 4 53 6 57 3 61 3 65 3 69 4 80 6 67 1 53 9 57 6 61 5 65 5 69 6 82 4 68 54 3 57 9 61 8 65 8 69 8 84 2 69 8 54 6 58 1...

Page 9: ...2 6 5974 5167 4537 3938 3387 77 64 4 6232 5391 4733 4108 3533 78 8 64 4 6431 5563 4884 4240 3646 80 6 67 1 6630 5735 5035 4371 3759 82 4 68 6888 5958 5231 4541 3905 84 2 69 8 7081 6125 5378 4668 4014...

Page 10: ...9 65 0 69 2 78 8 64 4 53 4 57 2 61 2 65 2 69 3 80 6 67 1 53 7 57 4 61 4 65 4 69 5 82 4 68 54 1 57 7 61 7 65 7 69 7 84 2 69 8 54 4 58 0 61 9 65 8 69 9 86 71 6 54 7 58 3 62 1 66 1 70 1 80 90 100 110 12...

Page 11: ...524 66 6156 8056 9956 11856 13961 16065 68 5700 7600 9500 11400 13503 15606 70 5428 7308 9188 11068 13184 15300 72 5132 7006 8881 10755 12874 14994 73 4649 6554 8459 10364 12449 14535 75 4189 6097 800...

Page 12: ...2 62 6 52 7 56 5 60 6 64 7 68 9 77 64 4 53 0 56 8 60 9 65 0 69 1 78 8 64 4 53 3 57 1 61 1 65 2 69 3 80 6 67 1 53 6 57 3 61 3 65 3 69 5 82 4 68 54 0 57 6 61 6 65 6 69 7 84 2 69 8 54 3 57 9 61 8 65 8 6...

Page 13: ...70 6252 77 64 4 11506 9952 8738 7585 6523 78 8 64 4 11873 10270 9017 7827 6731 80 6 67 1 12240 10588 9296 8069 6939 82 4 68 12716 10999 9657 8383 7209 84 2 69 8 13072 11308 9928 8618 7411 86 71 6 1346...

Page 14: ...water Indoor air 44 49 54 59 64 75 2 62 6 52 6 56 5 60 6 64 7 68 9 77 64 4 53 0 56 8 60 9 64 9 69 1 78 8 64 4 53 3 57 1 61 1 65 1 69 3 80 6 67 1 53 6 57 3 61 3 65 3 69 4 82 4 68 54 0 57 6 61 6 65 6 69...

Page 15: ...13605 11768 10333 8969 7713 77 64 4 14194 12278 10780 9357 8047 78 8 64 4 14647 12670 11124 9656 8304 80 6 67 1 15100 13062 11468 9954 8561 82 4 68 15687 13569 11914 10341 8893 84 2 69 8 16127 13950...

Page 16: ...88 8 95 9 103 0 110 1 116 5 122 8 68 89 3 96 4 103 5 110 6 117 0 123 3 70 89 6 96 7 103 8 110 9 117 3 123 7 72 89 9 97 0 104 1 111 2 117 6 124 0 73 90 3 97 4 104 5 111 6 118 0 124 5 75 90 8 97 9 105 0...

Page 17: ...17 Please note The chart above refers to GPM per Fan Coil and not GPM per CX30...

Page 18: ...nstallation or operation It is important that the electrical installation is compliant with all NEC and local electrical codes The appliance must be installed in a suitable position for easy access wh...

Page 19: ...e covers With the fan coil lying face down on the box locate the rubber plug on the outside cover and remove the screw behind it Gently tap the bottom of the side cover and remove the cover Do the sam...

Page 20: ...he bracket fig 11 ref B included with the FCU The bracket is a one piece that is shipped attached to the back of the fan coil Attaching the Feet Before you install the unit on the floor the feet shoul...

Page 21: ...the condensate discharging pipe and the wall box including the power supply cable Then mount the fastening bracket according to the holes on the template 2 The bracket must be fastened to the wall by...

Page 22: ...22 5 Hydronic Connections Floor installation wall installation To connect the inlet and outlet water pipes refer to the figures below...

Page 23: ...keep an inclination of at least 1 The drain pipe is connected to the pan positioned under the heat exchanger coil drain 1 If the condensate is discharged into the drainage system it is recommended to...

Page 24: ...l mounted Fan Coil and furniture present in the room To remove the side opening refer to page 19 for detailed instructions Dismount the upper grill fig 25 ref A by unscrewing the attaching screws Remo...

Page 25: ...so that the unit is level and ensure the condensation drain pipe is connected to the 5 8 OD port for condensation water draining when mounted on the ceiling fig 27 Mount the unit checking that it fit...

Page 26: ...26 8 Hydronic connections horizontal installation 8 1 Refer to fig 29 and fig 30 to connect the inlet and outlet lines Fig 29 Fig 30 Inlet and outlet water lines are NPT...

Page 27: ...clean the strainer regularly 1 Remove the plastic tape which is used to secure the air inlet grill during shipping A Fig 33 2 Next lift the grill upward about Fig 34 the grill will pop up automaticall...

Page 28: ...nd the air return grille to the original place Fig 39 6 Clean up the units outer cover with a soft damp rag Fig 40 To protect the paint use a mild detergent Warning Cut off power supply before cleanin...

Page 29: ...ton and select the fan speed you want to set High fan speed High fan speed indicator light keeps on blue Medium fan speed Medium fan speed indicator light keeps on yellow Low fan speed Low fan speed i...

Page 30: ...this button once You could increase the setting temperature by pressing this button again You could check the setting temperature of unit by pressing this button once You could increase the setting t...

Page 31: ...31...

Page 32: ...If you press the on off button when the controller is showing the parameter value it will switch back to the main interface without saving the setting 3 If there is no operation in 20 seconds system...

Page 33: ...Heating mode If the room temp is 68 F and parameter 20 1 the fan coil will run for 1 min every 15 min 68 F Factory 07 In heating mode if the coil temp is lower than Parameter 07 the fan motor will sto...

Page 34: ...REMOTE CONTROL Note 1 The key SET and OK are disabled 2 Take out the batteries if you do not use the remote controller for a long time 3 Take out the batteries for 35 minutes to reset the remote contr...

Page 35: ...rs If the setting value is over 11 hours the setting of timing will be cancelled Sleeping Function To start or cancel the sleeping function please press the key The sleeping function can only be set i...

Page 36: ...36 5 Wiring Diagram NO Signal meaning 1 CN2 DC Fan Motor 2 TEMP Sensors To ambient and coil temperature 3 OUT1 To electromagnetic valve 4 L Hot wire 120 vac Power in 5 N Neutral wire Power in...

Page 37: ...6 Standard Fan Coil Loop Pump Wiring Typical control circuit for adding a second pump to a fan coil Loop using SPST 24vac coil relays Relays must have the proper contact load rating for the selected p...

Page 38: ...57 12 2 23 8424 91 4 3 6955 170 6 0 8695 14 0 22 7155 93 2 3 5620 172 4 0 8441 15 8 21 6486 95 0 3 4340 174 2 0 8196 17 6 20 6380 96 8 3 3113 176 0 0 7959 19 4 19 6806 98 6 3 1937 177 8 0 7730 21 2 18...

Page 39: ...ode Cause Solution Indoor ambient P4 Ambient temperature Check or replace the temperature sensor sensor is in open circuit ambient temperature sensor or short circuit P5 Coil temperature sensor Check...

Page 40: ...40 9 Exploded Views Chiltrix CXI34...

Page 41: ...oting 13 30036 20031 Right wind shield 41 30036 220006 Hook 14 30036 220035 Electric box 42 30034 210005 Front panel 15 30036 220012 Cover of control panel 43 30034 210003 Air deflector 16 30036 22001...

Page 42: ...42 Chiltrix CXI65...

Page 43: ...08 Right Support 40 30036 220019 Footing 13 30036 20031 Right wind shield 41 30036 220006 Hook 14 30036 220035 Electric box 42 30034 210005 Front panel 15 30036 220012 Cover of control panel 43 30034...

Page 44: ...44 Chiltrix CXI85...

Page 45: ...Right Support 40 30036 220019 Footing 13 30036 20031 Right wind shield 41 30036 220006 Hook 14 30036 220035 Electric box 42 30034 210005 Front panel 15 30036 220012 Cover of control panel 43 30034 210...

Page 46: ...46 Chiltrix CXI120...

Page 47: ...ht Support 40 30036 220019 Footing 13 30036 20031 Right wind shield 41 30036 220006 Hook 14 30036 220035 Electric box 42 30034 210005 Front panel 15 30036 220012 Cover of control panel 43 30034 210003...

Page 48: ...48 Chiltrix CXI148...

Page 49: ...31024 210010 Air deflector 3 33 31022 220010 Left top cover 11 31022 210043 Fan holder 34 31024 210013 Back support 12 20000 330086 DC fan motor 35 31022 210039 Left Panel 13 31022 210044 Fixed panel...

Page 50: ...50...

Reviews: