正常に動作しない場合の対策

   

Countermeasures against Abnormal Operation 

 
 
 
 
 
 
 
 
 
 

故障現象

 

Failure phenomenon

 

原因

 

Cause

 

対策・方法

 

Countermeasures

 

①モ-タが起動しない。

 

運転中に突然停止した。

 

The motor is not started. 
The motor stops 
suddenly during 
operation.

 

電源が入っていない

 

The power is not turned on.

 

電源を入れる

 

Turn on the power 

モータ焼け

 

Motor seizing 

モータ交換(修理依頼願います)

 

Replace the motor.    (Ask for repair.) 

過負荷・異常温度

 

により、停止した。

 

The motor stops due to 
overload or abnormal 
temperature. 
 

[1] 

排気口

/

吸引口が塞がれていないか確認

 

(完全にふさがれると過負荷ランプが点灯します)

 

Check  whether  the  exhaust  port  and  suction 
port are not clogged. 
  (When  they  are  fully  clogged,  the  overload 
lamp is turned on.) 

[2] 

定格電圧の確認。

 

(タコ足配線になっていないか)

 

Confirm the rated voltage.     
(Confirm  that  star-burst  connection  is  not 
adopted.) 

[3] 

フィルタの目詰まりによりモータが過熱していないか
確認。

 

Confirm  that  the  motor  is  not  overheated  by 
clogged filters. 

 

ヒューズが切れた

 

Fuses are blown out 

ヒューズ(内部基板)を交換する(ヒューズについて参照)

 

Replace fuses

Internal board

. (Refer to Fuse) 

②吸引力低下

 

The suction force is 
deteriorated. 

フィルタの目詰まり

 

Filters are clogged. 

フィルタ交換

 

(目詰まりを放置すると③④の故障となります)

 

  Replace filters. 
(Clogged filters lead to the failures [3] and [4] 
below.) 

③粒子吹きもれ

 

Particles are not blown 
completely. 
 

フィルタ取り付け不良

 

Filters are not installed 
correctly. 

フィルタの取付け

 

Install filters correctly 

フィルタの破損、寿命

 

Filters are damaged, or 
their life is expired. 

フィルタ交換

 

Replace filters 

フィルタの目詰まり

 

Filters are clogged. 

フィルタ交換

 

Replace filters. 

④送風機異常音、

 

異常振動

 

  The blower is generating 
abnormal sounds or 
abnormal vibrations 

ブロア内への異物混入

 

  Foreign substances have 
entered the blower. 

修理依頼願います

 

Ask for repair. 

電動機軸受けの破損

 

The motor bearing is 
damaged. 

電動機交換(修理依頼願います)

 

Replace the motor.    (Ask for repair.) 

Summary of Contents for CKU-050-SP

Page 1: ...clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this CKU Series machine correctly so that you can use it safely for a long time and e...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...me of main body 6 3 2 Standard accessories 6 4 Operation 7 4 1 Power supply 7 4 2 Confirmation before operation 7 4 3 Operation procedure 8 5 Maintenance and Inspection 8 5 1 Cautions on maintenance a...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...odification Do not disassemble or modify the machine Disassembly and modification may cause an electrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose o...

Page 6: ...of main body 3 2 Standard accessories Primary filter Collecting Adsorbing fine dust and fumes Secondary filter Protecting the circuit and the electrical parts Exhaust port BOX Fuse Box ON OFF ON OFF s...

Page 7: ...d to the item 4 ON OFF Turn on the main power switch and push the ON OFF switch of the front Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the suction hose is con...

Page 8: ...Filter replacement timing Replace the primary filter when suction force declines But when it is not improved in spite of the replacement of the primary filter replace the secondary filter Clogging th...

Page 9: ...hould be located on the exhaust side 1 1 Remove the primary filter from the filter case The paper packing of the primary filter is inserted into the cylindrical pipe of the filter case Pull the paper...

Page 10: ...ption Filter case Before operation Is the case closed completely Exhaust status Once day Is the exhaust port unclogged Vibrations of main body Once day Are no abnormal vibrations or sounds generated I...

Page 11: ...ated voltage Confirm that star burst connection is not adopted 3 Confirm that the motor is not overheated by clogged filters Fuses are blown out Replace fuses Internal board Refer to Fuse The suction...

Page 12: ...SP 50 100V 1 2 50 60 2 5 1 75 60 8 7 A B Note The Noise column indicates a value dB on the scale A at 1 m on the main body side when hose is connected to the suction port 10 10 10 10 Consumable Parts...

Page 13: ...Memo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 1 1 33 1 1 33 Hakushima Minoh City Osaka apan 562 0012...

Reviews: