background image

チコーエアーテック株式会社 

Copyright CHIKO AIRTEC CO., LTD. 2015 

 

 

 

  8

 

 

 

 

4

 

操作 

Operation

 

 

4.1 

電源について 

Power supply 

 

本機の電源は、単相電源です。

The power supply is single-phase, 

 

供給電圧の許容範囲は、±

10

%です。

 

電源コード(コード長さ

3m

)付きです。(アース付プラグ)

 

The allowable supply voltage range is ±10%. 
The power cable of 3 m with a grounding plug is included. 
 
 

4.2 

AT2

パネルについて 

AT2 panel 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 

 

異なった電源で運転されますと、故障の原因になります。

 

Operating the product with a different power supply may cause a failure. 

 

3

分以上のインターバルをおいて、

ON/OFF

の操作を行ってください。

 

それ未満、特に

30

秒未満の

ON/OFF

を繰り返すと故障の原因となります。

 

Allow an interval of at least three minutes before turning the equipment ON or 

OFF. If the equipment is turned ON or OFF repeatedly at a shorter interval, 

particularly within 30 seconds,it may malfunction. 

 

①  ON ボタン 

ON button 

③  Lo ボタン 

Lo button 

 

③  Hi ボタン 

Hi button 

②  OFF ボタン 

OFF button 

⑦  能力レベル 
Capacity Level 

⑥  運転圧力表示 
Operating Pressure   
Indication(kPa) 

⑤  風量不足   
    Volume down

 

 

④  圧力不足 
    Pressure down 

   

 

   

 

   

 

   

 

   

 

   

 

 

 

Summary of Contents for CBA-080AT2-HI

Page 1: ...safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbol indicates actions that should not be performed in any case or actions that may lead to a serious...

Page 2: ...benzene kerosene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire so...

Page 3: ...AT2 panel 8 4 3 Remote connector 11 4 4 Confirmation before operation 11 4 5 Operation procedure 11 5 Remote Cable Sold Separately 12 5 1 Electrical circuit diagram 12 5 2 Color and signal of each wir...

Page 4: ...utdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical...

Page 5: ...ine Disassembly and modification may cause an electrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confi...

Page 6: ...The remote cable is so designed as to be prevented from falling off Insert it securely with its dent facing downward Make sure to confirm pin positions Power cable The cable is different in each regi...

Page 7: ...Replacement flanges are sold separately Removal method 65 CBA 080AT2 HC 75 CBA 500 1200 AT2 HC Turn the flange counterclockwise to remove it Turning it to clockwise tightens the flange Diameter of ins...

Page 8: ...Operating the product with a different power supply may cause a failure 3 ON OFF 30 ON OFF Allow an interval of at least three minutes before turning the equipment ON or OFF If the equipment is turned...

Page 9: ...hts when the suction power decreases due to a factor such as an open front door a clogged exhaust filter or a blocked exhaust duct The lamp turns off when the cause of the problem is corrected Volume...

Page 10: ...lay that indicates operational pressure is decimal number from 2 to 3 Initial value is 2 Step by step mode is changed by pressing HI LO button unit kPa Operation level 220V 220V mode 230V 230V mode Ma...

Page 11: ...switch and confirm that the MAIN POWER indicator lamp of AT2 panel lights AT2 ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm t...

Page 12: ...nce 4 7k Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relay...

Page 13: ...Copyright CHIKO AIRTEC CO LTD 2015 13...

Page 14: ...r short circuiting pins and short circuit pin to start operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT2 panel is disable...

Page 15: ...ire AT2 ON Lo Hi To change the capacity level using the buttons on the main unit when switching to remote operation check that pin is not shorted circuited then press and hold the ON button on the AT2...

Page 16: ...e filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspe...

Page 17: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 18: ...w lamp status Suction force check During operation Does the suction hose end offer proper suction force Is the clogging indicator lamp extinguished When the fuse is blown out by excessive current gene...

Page 19: ...of several plugs in one outlet is not adopted 3 Confirm that the motor is not overheated by clogged filters Fuses are blown out 6 7 Replace fuses Refer to Fuse The suction force is deteriorated Filter...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2015 20 8 Indication of DANGER Labels 9 Electrical Circuit Diagram CE MODEL CBA 080AT2 HI CE...

Page 21: ...Copyright CHIKO AIRTEC CO LTD 2015 21 CBA 1200AT2 HC CE CBA 500AT2 HC CE...

Page 22: ...Copyright CHIKO AIRTEC CO LTD 2015 22 CBA 2000AT2 HI V1 CE...

Page 23: ...ingle phase 3 6 50 60 2 2 8 0 57 70 10 0 CBA 080AT2 HI CE 450 220 230 Single phase 3 6 50 60 2 2 9 1 10 4 57 70 10 0 CBA 500AT2 HC 450 100 115 Single phase 6 5 50 60 3 2 9 5 61 65 17 8 CBA 500AT2 HC T...

Page 24: ...months CHF 2525 50 CHF 3030 50 CHF 3030 50 CHF 3535 70 6 12 Exhaust filter 6 to 12 months CHF 2525 50 CHF 3030 50 CHF 3030 50 HEP 3535 69 V1 6 12 Exhaust filter 6 to 12 months HEP 2525 50 HEP 3030 69...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: