R3250Hz Universal Outdoor Series Technical Manual
64
GD Chigo Heating & Ventilation Equipment Co., Ltd.
6. Capacity Tables
Cooling
6.1 CTA-18HVR4
MODEL
CTA-18HVR4
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
49 ºC
21ºC DB
15ºC WB
Total capacity kW
5.09
5.06
5.03
4.99
4.95
4.91
4.88
Input kW.
1.50
1.51
1.53
1.55
1.60
1.66
1.71
24ºC DB
17ºC WB
Total capacity kW
5.25
5.22
5.18
5.15
5.10
5.06
5.03
Input kW.
1.52
1.53
1.55
1.57
1.63
1.68
1.73
27ºC DB
19ºC WB
Total capacity kW
5.41
5.38
5.34
5.30
5.26
5.22
5.18
Input kW.
1.54
1.55
1.57
1.59
1.65
1.70
1.75
29ºC DB
21ºC WB
Total capacity kW
5.48
5.44
5.40
5.36
5.32
5.28
5.24
Input kW.
1.56
1.58
1.60
1.62
1.67
1.73
1.78
32ºC DB
23ºC WB
Total capacity kW
5.58
5.55
5.51
5.47
5.42
5.38
5.34
Input kW.
1.57
1.58
1.60
1.62
1.68
1.74
1.79
6.2 CTA-24HVR4
MODEL
CTA-24HVR4
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
49 ºC
21ºC DB
15ºC WB
Total capacity kW
6.82
6.78
6.73
6.68
6.63
6.58
6.53
Input kW.
2.03
2.05
2.07
2.10
2.17
2.25
2.31
24ºC DB
17ºC WB
Total capacity kW
7.04
7.00
6.95
6.89
6.84
6.78
6.74
Input kW.
2.05
2.07
2.10
2.12
2.20
2.28
2.34
27ºC DB
19ºC WB
Total capacity kW
7.25
7.21
7.15
7.00
7.04
6.99
6.94
Input kW.
2.08
2.10
2.12
2.15
2.23
2.31
2.37
29ºC DB
21ºC WB
Total capacity kW
7.34
7.29
7.24
7.19
7.13
7.07
7.03
Input kW.
2.11
2.13
2.16
2.19
2.26
2.34
2.41
32ºC DB
23ºC WB
Total capacity kW
7.48
7.43
7.38
7.32
7.26
7.21
7.16
Input kW.
2.12
2.14
2.17
2.19
2.27
2.35
2.42
6.3 CTB-36HVR4, CTB-36HVR4S
MODEL
CTB-36HVR4
, CTB-36HVR4S
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
49 ºC
21ºC DB
15ºC WB
Total capacity kW
10.09
10.03
9.96
9.88
9.80
9.73
9.66
Input kW.
3.08
3.11
3.14
3.18
3.30
3.41
3.51
24ºC DB
17ºC WB
Total capacity kW
10.41
10.35
10.27
10.19
10.11
10.03
9.97
Input kW.
3.12
3.15
3.19
3.22
3.34
3.46
3.55
27ºC DB
19ºC WB
Total capacity kW
10.72
10.66
10.58
10.50
10.42
10.33
10.27
Input kW.
3.16
3.19
3.23
3.27
3.38
3.50
3.60
29ºC DB
21ºC WB
Total capacity kW
10.85
10.79
10.71
10.63
10.54
10.46
10.39
Input kW.
3.21
3.24
3.28
3.32
3.44
3.56
3.66
32ºC DB
23ºC WB
Total capacity kW
11.06
10.99
10.91
10.83
10.74
10.66
10.59
Input kW.
3.22
3.25
3.29
3.33
3.45
3.57
3.68