background image

Installation Instructions

SL151

9

NOTE:

If installing the SL151 in a drywall ceiling, remove the

outside terminal block and cover with plate (C), using
four 6-32 x 3/16" Phillips pan head screws (F).

Wiring Options

NOTE:

Refer to Table 1: Wiring Table and (See Figure 16) for

information on all wiring options.

NOTE:

Refer to Table 2: Terminal Descriptions and (See

Figure 16) for terminal descriptions, functions and
wiring options.

Re-Attaching Ceiling Panel

1.

Line up rectangular holes in ceiling panel with clips on ends
of rods, and re-attach the ceiling panel. (See Figure 14)

CAUTION:

Damage to equipment could result if clips are

not lined up properly with rectangular holes.

Figure 14

2.

Carefully insert clips into rectangular holes in ceiling panel.

3.

Reattach guide wires (two places) to ceiling panel, using
screws removed earlier. (See Figure 15)

Figure 15

Rectangular
Holes

Clips

x 2

Ceiling
Panel

Guide
Wire

Summary of Contents for SMART-LIFT SL151

Page 1: ...rference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer...

Page 2: ...ING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Always turn off power at source before putting on or taking off parts Use this mounting system only for its intended use as des...

Page 3: ...elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen...

Page 4: ...2 578 6 514 1 582 7 22 50 20 28 215 9 284 5 579 4 571 5 65 5 DIMENSIONS MILLIMETERS INCHES TABLE OF CONTENTS Disclaimer 2 Tools Required For Installation 3 Parts 3 Legend 3 Dimensions 4 Installation...

Page 5: ...and wire the push button assembly D to contacts 1 red and 6 black See Figure 3 Figure 3 6 Plug in the SL151 test cord See Figure 2 NOTE See Figure 2 for location of external wiring terminal See Figur...

Page 6: ...sibility to make certain the structure to which the lift is being mounted is capable of supporting five times the weight of the lift and all attached equipment Reinforce the structure as required befo...

Page 7: ...lation 2 Use the provided push button D to operate the SL151 up and down ensuring that all clearances are adequate Installing Projector on SL151 NOTE The projector is secured from the top by an SLB br...

Page 8: ...for up and down movement of the lift 5 Secure cables as necessary using supplied mounting pads E and cable ties B CAUTION KEEP SL151 OPEN WHILE PROJECTOR IS RUNNING OR IN COOLING MODE Premature bulb f...

Page 9: ...See Figure 16 for terminal descriptions functions and wiring options Re Attaching Ceiling Panel 1 Line up rectangular holes in ceiling panel with clips on ends of rods and re attach the ceiling panel...

Page 10: ...0 Table 1 WIRING TABLE Figure 16 NOTE The numbers listed in the SL151 Internal and SL151 External columns refer to the corresponding numbers located where indicated in the wiring pictures See Figure 1...

Page 11: ...Installation Instructions SL151 11 Table 2 INTERNAL TERMINAL DESCRIPTIONS...

Page 12: ...SL151 Installation Instructions 12 Figure 17...

Page 13: ...Installation Instructions SL151 13...

Page 14: ...SL151 Installation Instructions 14...

Page 15: ...Installation Instructions SL151 15...

Page 16: ...Company www chiefmfg com 04 10 USA International A 8401 Eagle Creek Parkway Savage MN 55378 P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Nether...