4.
Install latching flag (C) using one 10-24 x 1/2" flat head
Phillips screw (D), one spacer (G), and one 10-24 lock nut
(F). (See Figure 4)
Figure 4
Attaching PSMH2860 to Wall
1.
Place mounting system against wall in desired installation
location.
2.
Level and adjust PSMH2860 making certain slots in upper
and lower horizontal brackets are properly positioned over
studs for either a single stud installation (landscape or
portrait) or a dual stud installation (landscape only). (See
Figure 5)
Figure 5
3.
Mark the location of four mounting holes (or two mounting
holes for single stud mounting holes) onto wall. (See Figure 5)
Table 1: Fastener Information
4.
Drill four pilot holes (two for single stud install) at marked
locations. (See Table 1)
5.
Proceed to either
Wood Stud
or
Concrete
section for
attachment instructions.
CAUTION:
IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! DO NOT over
tighten hardware!
IMPORTANT ! :
See Table 1 for appropriate hardware
and pilot hole sizes for various wall types.
Wood Stud
1.
Use one 5/16" x 2-3/4" hex head lag bolt (H) through one
5/16" washer (J), the PSMH2860 and into pilot hole. (See
Figure 6)
2.
Repeat for remaining pilot hole(s).
Figure 6
4
(D)
(C)
(F)
(G)
[Attaching latching flag in portrait version]
Dual Stud Attachment Points
Single Stud Attachment Points
LANDSCAPE
PORTRAIT
Single Stud
Attachment Points
WALL
TYPE
PILOT
HOLE
FASTENERS (see PARTS
drawing)
Wood
stud
(2" x 4")
7/32" x 3"
5/16 x 2-3/4" hex head lag (H)
& 5/16" washer (J)
. Fasteners
placed at stud locations, min.
16" (400mm) and max. 24"
(610mm).
Concrete
3/8" x 3-1/2"
5/16 x 2-3/4" hex head lag (H)
& UX10x60R anchor (K).
Fasteners placed a min. 16"
(400mm) and max. 24"
(610mm).
1
2
(H)
(J)