Installation Instructions

OB1U

5

ASSEMBLY AND INSTALLATION

The OB1U will allow an interactive flat panel display to be
installed over an existing chalkboard/whiteboard. The OB1U
has telescoping legs which allows it to be anchored above and
below the existing chalkboard/whiteboard.

Adjusting OB1U Legs

1.

Tip and lift outer portion of upright assembly out of the
shipping slot, and slide down to extend the length of OB1U
leg. (See Figure 1)

2.

Choose a slot to set the correct length of entire upright
assembly, and tip outer portion upright into appropriate slot.
(See Figure 1)

3.

Repeat Steps 1 and 2 on the other upright assembly (P).

Figure 1

NOTE:

The lower wall bracket (V) is

OPTIONAL

if the upright

assemblies (P) are attached to a concrete wall

4.

Attach one lower wall bracket (V) to each of the upright
assemblies (P) using one 1/4-20 x 1/2" flat head cap screw
(A) and one 1/4-20" hex nut (E) on each lower wall bracket.
(See Figure 2)

Figure 2

Locate Mounting Site

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installers
responsibility to make certain the structure to which the
mount is being attached is capable of supporting five times
the weight of the OB1U and all attached equipment not to
exceed 310 lbs (140.6 kg).

WARNING:

ELECTRICAL SHOCK, EXPLOSION AND

FIRE HAZARD! CUTTING OR DRILLING INTO
ELECTRICAL CORDS, CABLES OR GAS PLUMBING CAN
CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surface is free
of electrical wires, cables, gas, water, waste, or any other
plumbing before drilling or installing fasteners.

Adjusting Wall Brackets for Installation

NOTE:

The two outside wall brackets on the wall assembly

may be adjusted to suit installation needs, but each
must be spaced a

minimum

 of 16" from the center wall

bracket,

AND

 the two outside wall brackets may be a

maximum

 of 48" apart (outside bracket to outside

bracket).

NOTE:

The center wall bracket must remain in the center of the

wall assembly (T).

1.

Slide outside wall brackets along wall assembly (T), as
required, for the wall substrate. (See Figure 3)

2.

Tighten button head cap screw on each wall bracket to
secure wall brackets to wall assembly. (See Figure 3)

Figure 3

NOTE:

Proceed to the

Installing to a Wood Stud Wall

section, or the

Installing to a Concrete or Concrete

Block Wall

section, or the

Installing to a Steel Stud

Wall

section, as appropriate.

1

2

(P) inner

(P) - outer portion

    portion

(V)

4

(A)

(E)

(P)

2

x 3

1

(side view)

1

(T)

Wall brackets

Summary of Contents for OB1U

Page 1: ...R U C T I O N S Interactive Flat Panel Over White Board Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description OB1U ...

Page 2: ...ONS WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all mounting systems are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this mounting system can result i...

Page 3: ...Installation Instructions OB1U 3 DIMENSIONS DIMENSIONS INCHES MILLIMETERS ...

Page 4: ...m D1 4 M8x12mm E1 4 M8x20mm F1 4 M8x30mm G1 8 H1 4 Universal washer L 10 Drywall anchor R 4 Bumper plate retainer X 1 Cross bracket V 2 Lower wall bracket T 1 Wall assembly assembly Optional Spacer XL Display Hardware Kit A 2 1 4 20 x 1 2 B 2 1 4 20 x 3 8 C 4 1 4 20 x 3 4 D 2 1 16 E 2 1 4 20 G 10 1 4 H 1 5 32 I 10 1 4 20 x 1 3 4 J 10 1 4 x 2 1 2 K 10 UX8 x 50R M 4 Bumper N 4 4 knob U 2 Lower brack...

Page 5: ...the mount is being attached is capable of supporting five times the weight of the OB1U and all attached equipment not to exceed 310 lbs 140 6 kg WARNING ELECTRICAL SHOCK EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO ELECTRICAL CORDS CABLES OR GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of electrical wires cables gas water wa...

Page 6: ...assembly T AND a minimum of 16 from both outside wall brackets NOTE Leave a minimum of 1 between the bottom of the wall assembly brackets and the top of the existing chalkboard whiteboard This will allow enough space to install the wall bracket covers Q at a later time 2 Using the wall assembly T mark the wall above existing chalkboard whiteboard through mounting holes in each bracket See Figure 5...

Page 7: ...lled to a minimum of one stud left and right of the stud s being used to install the mount Drywall must be secured to studs with screws a maximum of 12 305mm apart down center of stud Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Members 362 S 125 18 C Shaped S Stud Section See hazard statement on page 2 Drywall 1 ...

Page 8: ... Repeat Steps 5 through 8 for each mounting hole Figure 10 10 Place wall brackets of wall assembly T over installed anchors and align mounting holes in wall brackets with holes in anchors See Figure 11 11 Insert 1 4 20 x 1 3 4 Phillips pan head screws I through 1 4 washer G corresponding mounting hole on wall bracket and into anchor L and tighten until flush against wall bracket DO NOT over tighte...

Page 9: ...et X by inserting two 1 4 20 x 3 4 button head flange screws C through lower mounting holes in cross bracket See Figure 13 5 The mounting system may be laterally shifted by moving the upright assemblies P laterally along the wall assembly T to the desired location 6 Tighten the button head cap screws on the wall brackets to fasten the wall assembly in place See Figure 12 Figure 13 7 Move the slide...

Page 10: ...r being installed The center of interface bracket is indicated by the diamond shaped hole See Figure 16 3 Pull down on interface bracket handles to open for attaching to OB1U See Figure 15 4 Hang flat panel with attached interface brackets onto the cross bracket X ensuring that one interface bracket is on each side of the cross bracket center line CL See Figure 16 NOTE Two slots on cross bracket i...

Page 11: ...ng cover S down over the wall bracket cover Q on three wall assembly brackets See Figure 19 Figure 19 Completing Attachment to Wall IMPORTANT See Adjustment and Leveling of Micro Height Adjust and Adjustment of Lower Leg Plumb sections to make any necessary adjustments BEFORE completing attachment to wall NOTE The lower part of the OB1U must be attached to the wall using the correct hardware for t...

Page 12: ...See Figure 21 Figure 21 4 Hold metal channel on drywall anchor L flat alongside plastic straps and slide channel through hole See Figure 22 Figure 22 5 Holding plastic straps on drywall anchor L pull anchor away from wall until channel rests flush behind wall See Figure 23 6 Slide plastic cap on anchor L towards wall until flange of cap is flush with wall See Figure 23 Figure 23 7 Snap off plastic...

Page 13: ...5 Rotate the lower wall bracket back into place 6 Use two 1 4 x 2 1 2 lag bolts J and two 1 4 flat washers F to attach each lower wall bracket V to anchors in wall See Figure 26 Adding Stabilizing Hardware 1 Attach two bumper plate retainers R two 4 knobs N and two bumpers M through each leg assembly one just below top of flat panel and one just above bottom of flat panel See Figure 27 2 Adjust 4 ...

Page 14: ...allation Instructions 14 Adjustment of Lower Leg Plumb 1 Turn the buttonhead screw at bottom of leg if necessary to adjust the plumb on lower leg so that it sets firmly against the wall See Figure 29 Figure 29 1 ...

Page 15: ...Installation Instructions OB1U 15 ...

Page 16: ...003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 OB1U Installation Instructions Chief a products division of Milestone AV Technologies 8800 003010 Rev00 2017 Milestone AV Technologies www milestone com 12 17 ...

Reviews: