Installation Instructions

NW1 Racks

5

INTRODUCTION

The NW1 wall racks have been designed to be mounted onto a
2" x 4" wood stud (16" on center) wall.

IMPORTANT ! :

Do NOT load wall rack until after

installation is complete.

INSTALLATION

Locate Mounting Site

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installers
responsibility to make certain the structure to which the
mount is being attached is capable of supporting five times
the weight of the NW1 and all attached equipment.

Installing to a Wood Stud Wall

Determine location of NW1 wall rack, ensuring it is centered
between wood studs and will be attached to two 2" x 4" studs.

NOTE:

Decide on which side of the NW1 rack the hinge will be
located. It is possible to place the rack near a corner, if
required, since it is possible to operate the latch from
the front of the rack.

WARNING:

ELECTRICAL SHOCK HAZARD! CUTTING

OR DRILLING INTO ELECTRICAL CORDS OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surface is free
of electrical wires and cables before drilling or installing
fasteners.

WARNING:

EXPLOSION AND FIRE HAZARD! CUTTING

OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surface is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.

1.

Using the rack rear section (A) as a template, mark the wall
at the center of each stud through top mounting slots. (See
Figure 1)

2.

Drill one 7/32" pilot hole at both marks made in Step 1. (See
Figure 1)

3.

Loosely install two 5/16 x 2-1/2" lag bolts (P) and two 5/16"
flat washers (Q) into pilot holes.

4.

Hang rack rear section (A) onto lag bolts, and slide to
narrow section of mounting slots. (See Figure 1)

5.

Tighten lag bolts installed in Step 3.

6.

Mark the attachment points for the lower mounting slots,
making sure the attachment points are centered on the
studs. (See Figure 2)

NOTE:

The number of mounting slots varies and is dependent
upon NW1 model being installed.

7.

Drill 7/32" pilot holes at markings for lower mounting holes.
(See Figure 2)

8.

Use 5/16 x 2-1/2" lag bolts (P) and 5/16" flat washers (Q) to
complete installing rack rear section (A) to the wall through
the lower mounting holes. (See Figure 2)

Figure 1

Figure 2

1

2

3

      (P) x 2

(rear view)

(Q) x 2

(A)

4

6

8

      (P)

(Q)

7

Summary of Contents for NW1 series

Page 1: ...Instruções de Instalação Istruzioni di installazione Installatie instructies Instructions d installation Sectional Wall Rack Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description NW1 Racks ...

Page 2: ...tructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which...

Page 3: ...lemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken M...

Page 4: ...1 rack rear section B 1 NW1 rack center section NW1 Hardware Kit C 2 10 24 x 3 8 D 2 08 32 x 3 8 E 2 3 8 16 x 2 F 2 Bumper G 1 Latch catch left H 1 Latch catch right J 1 5 32 security K 1 Latch assembly L 8 1 4 20 x 1 3 4 M 8 1 4 N 8 1 4 20 P 8 5 16 x 2 1 2 Q 8 5 16 R 8 Toggler Model NW1F2818 shown for Parts A B security ...

Page 5: ...e of electrical wires and cables before drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of gas water waste or any other plumbing before cutting drilling or installing fasteners 1 Using the rack rear section A as a template mark the wall at the...

Page 6: ...re 3 Latch Catch 2 Insert appropriate latch catch left or right G or H into slot in NW1 rack and adjust latch catch so that holes in latch catch match up with holes in rack See Figure 4 3 Attach latch catch using two 08 32 x 3 8 Phillips pan head screws D See Figure 4 Figure 4 Rubber Bumpers 4 Add rubber bumpers F to front of rack rear section A on side opposite the hinges See Figure 5 Figure 5 1 ...

Page 7: ...NOTE The alignment panels shipped with the racks are optional They may be removed to facilitate loading of the racks Load Distribution CAUTION BEGIN PLACEMENT OF LOAD AT BOTTOM OF RACK Load rack moving from bottom toward top of rack Loading rack incorrectly may result in instability causing possibly injury and or damage to components 1 Begin placement of components into the rack at the lowest poin...

Page 8: ...linstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief Manufacturing a products division of Milestone AV Technologies 8800 002098 Rev01 2012 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 08 12 ...