background image

Installation Instructions

FCA103

5

INSTALLATION

Locate Mounting Site

WARNING:

Exceeding the weight capacity can result in

serious personal injury or damage to equipment!  It is the
installer’s responsibility to make sure the combined weight of
all components atttached to the FCA103 does not exceed
250 lbs (113.4 kg) or the maximum weight limit of the specific
Fusion mount being attached. The maximum weight that can
be installed onto the FCA103 shelf is 30 lbs (13.6 kg).

The FCA103 can be installed to either wood studs or a concrete
wall. The minimum distance between fasteners must be 16"
whether installing to 2" x 4" wood studs or concrete.

NOTE:

Proceed to either the

Installing to a Wood Stud Wall

section or the

Installing to a Concrete Wall

section.

NOTE:

If already installed, Fusion mount must be uninstalled

prior to FCA103 installation. Set aside wall mounting
hardware as it will be used again for FCA103 mounting.

Installing to a Wood Stud Wall

1.

Determine the center of the TV screen, and where it should
be located on the wall.

2.

Locate the closest 2" x 4" stud to the left and right of the
selected location.

NOTE:

If the screen area lies over a stud, use that stud and the

stud to either the left or right of it.

3.

Line up the notches on mount (A) with center of screen
marking to determine vertical center. (See Figure 1)

4.

Measure up 8 3/4" (222.2 mm) from the center point to mark
location of the upper mounting slots.

Figure 1

5.

Using a level, mark the wall on each stud to attach the
brackets through the upper mounting slots. (See Figure 2)

WARNING:

ELECTRICAL SHOCK HAZARD! CUTTING

OR DRILLING INTO ELECTRICAL CORDS OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surface is free
of electrical wires and cables before drilling or installing
fasteners.

WARNING:

EXPLOSION AND FIRE HAZARD! CUTTING

OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surface is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.

6.

Drill one 7/32" (5.5mm) pilot hole in each stud.

7.

Use two 5/16 x 2-1/2" lag bolts and two 5/16" flat washers
to attach top of brackets (A and B) to wall. (See Figure 2)

NOTE:

If desired CPU location is off to the side of the display,
reverse brackets (A and B) from how they are shown in
Figure 2.

Figure 2

8.

Mark the attachment points for the lower mounting slots,
making sure the attachment points are located on the studs.
(See Figure 2)

9.

Drill 7/32" (5.5mm) pilot holes at markings for lower
mounting holes. (See Figure 2)

10. Use two 5/16 x 2-1/2" lag bolts and two 5/16" flat washers

to attach the mount to the wall through the lower mounting
holes. (See Figure 2)

11. Proceed to Installing Shelf to Brackets Section.

Center of screen

8-3/4"

Vertical center
of mount

(222.2mm)

8

9

5

6

x 4

7

10

 x 4

(A)*

(B)*

*reverse brackets to install CPU shelf to the outside

Summary of Contents for FCA103

Page 1: ...tru es de Instala o Istruzioni di installazione Installatie instructies Instructions d installation Fusion CPU Extender Accessory Spanish Product Description German Product Description Portuguese Prod...

Page 2: ...uction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipm...

Page 3: ...l Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche By Hand A mano Von Hand Com a m o A mano Met de hand la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a...

Page 4: ...FOR INSTALLATION PARTS 7 32 5 5mm Wood Stud 5 16 7 9mm Concrete 2 concrete only A 1 B 1 C 1 left wall bracket right wall bracket shelf bracket D 4 5 16 18 x 5 8 E 1 10 24 x 5 8 F 1 1 4 G 4 5 16 H 1 10...

Page 5: ...mm from the center point to mark location of the upper mounting slots Figure 1 5 Using a level mark the wall on each stud to attach the brackets through the upper mounting slots See Figure 2 WARNING...

Page 6: ...O GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of gas water waste or any other plumbing before cutting drilling or installing fasten...

Page 7: ...PU connections and place CPU securely on shelf 5 Use hook and loop strap J to secure CPU to shelf C See Figure 7 Figure 7 Installing Fusion Mount to FCA103 1 Use four 5 16 18 x 5 8 hex head bolts D an...

Page 8: ...5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 899...

Reviews: