background image

I N S T A L L A T I O N   I N S T R U C T I O N S

Instrucciones de instalación

Installationsanleitung

Instruções de Instalação

Istruzioni di installazione

Installatie-instructies

Instructions d´installation

Automated Dual Horizontal Door System

This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio or television
communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment to an outlet on a circuit other than that to which the receiver is connected

Consult the dealer or and experienced radio/TV technician for help

CM6DH SERIES

Summary of Contents for CM6DH SERIES

Page 1: ...le protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does caus...

Page 2: ...er s responsibility to make sure all components are properly assembled and installed using the instructions provided Read all instructions before using this furnishing DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK ALWAYS unplug this furnishing from the electrical outlet before cleaning WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Unplug from outlet before putting on o...

Page 3: ...CM6DH SERIES Installation Instructions 3 TOOLS REQUIRED FOR INSTALLATION PARTS 2 1 2 12 7mm A 1 B 1 C 2 F 2 D 1 E 1 08 x 1 2 G 1 ...

Page 4: ...ors to move in front of cabinet as well as above floor or carpet 5 Use of a quality surge protection device is suggested for mounting on top of cabinet to make electrical hook up of the mechanism and lights Installing to Cabinet 1 Place mechanism A on top of cabinet See Figure 1 2 Align center of track with center of the door opening 3 Attach using 8 or 10 screws through the holes in track 4 Attac...

Page 5: ...Installation Instructions CM6DH SERIES 5 Figure 1 ...

Page 6: ...CM6DH SERIES Installation Instructions 6 Figure 2 ...

Page 7: ...ure 5 Figure 5 4 Move carriages to one half open position by activating mechanism and pressing button a second time when carriage reaches desired position See Mechanism Activation section 5 Lift door and engage guidewheel into guidewheel space 6 Tip top of door in engaging the pendant bolts into keyhole in carriage arms See Figure 6 Figure 6 7 Adjust height and alignment of doors by turning the pe...

Page 8: ...ith the dimmer option installed cabinet lighting can be switched on or off or dimmed using the left buttons on the systems remote control To install the optional dimmer 1 Plug 115VAC lighting into the back of the Light Dimmer Module 2 Plug the other end of Dimmer Module cord into a 115VAC grounded receptacle on motor assembly CAUTION The Dimmer is for 120 volt incandescent or Halogen lamps of at l...

Page 9: ...ller will then be in Learn Mode The door will move for 3 seconds stop for 10 seconds and when it starts moving again it will be in it s Learn Mode When put into Learn Mode the mechanism runs back and forth several times and measures it s environment such as open and closed locations etc and then stops and remembers these learned measurements so that next time the system runs it knows where to star...

Page 10: ...ut 8 position RJ 45 modular phone jack Discrete control for use with 3rd party control Position 8 Open Position 7 Stop IR Receiver Eye input for Eubank Inc supplied external IR reciever only Position 6 V out Position 5 Vcc 5v Radio Power for external RF receiver only Position 4 24 VDC Sequence control for use with 3rd party control Position 3 Sequence Open Stop Close Stop Position 2 Common Discret...

Page 11: ...Installation Instructions CM6DH SERIES 11 ...

Page 12: ...77 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 8996 9217 D 24F 24F D 8820 000022 RevA 2007 Chief Manufacturing www chiefmfg com 11 07 ...

Reviews: