71
AIRCOMP
AIR Monitor
Completion
Condition Counts
(Secondary Air)
AIR Monitor Completion Condition
Counts (Secondary Air) displays
number of time that all conditions
necessary to detect an AIR system
malfunction have been encountered
(numerator).
AIRCOND
AIR Monitor
Conditions
Encountered Counts
(Secondary Air)
AIR Monitor Conditions Encountered
Counts (Secondary Air) displays
number of times that the vehicle has
been operated in the specified AIR
system monitoring conditions
(denominator).
EVAPCOMP
EVAP Monitor
Completion
Condition Counts
EVAP Monitor Completion Condition
Counts displays number of time that all
conditions necessary to detect a 0.020"
EVAP system leak malfunction have
been encountered (numerator).
EVAPCOND
EVAP Monitor
Conditions
Encountered Counts
EVAP Monitor Conditions
Encountered Counts displays number
of times that the vehicle has been
operated in the specified
EVAP system leak malfunction
monitoring conditions (denominator).