D.
The warning symbol together with the book
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.
E.
The CE symbol means that the machine is
EC-approved. See the EC declaration which is
delivered with the machine for more
information. If the CE symbol is missing, it
means that the machine is not EC-approved.
Safety label
To avoid injury, before using or servicing tool, read
and understand separately provided safety
instructions.
Installation
Preparation
Always make sure that the pump stands stable on a
level surface.
Depending on the conditions at the worksite, the
pump can be installed in different ways.
If a suction hose is connected to the liquid intake:
♦
The pump does not need to be partially
submersed into the pumped medium.
♦
Check that the open end of the suction hose is
completely submersed.
♦
The use of a suction hose can affect the pressure
head negatively.
If a suction hose is not used:
♦
Check that the liquid intake of the pump is fully
submersed into the pumped medium.
NOTICE
Never submerse the pump below muffler
level, into the pumped medium. When pumping
from a tank or dam, never let the muffler level be
below the liquid level in the tank or dam.
Fixed installation
The pump is primarily intended for use in temporary
(mobile) applications. If the pump is used in a fixed
installation, make sure that the connections between
pump and pipe are made with a flexible hose.
Hoses and connections
SR
NO
A
B
C
A.
Compressed air source
B.
Water separator (optional)
C.
Max. 10 feet (3 meter) compressed air hose
between the water separator and the machine.
♦
Check that you are using the correct
recommended operating pressure, 87 psig (6 bar).
♦
The maximum permissible air pressure, 90 psig
(6,2 bar), must not be exceeded.
♦
Blow any impurities out of the compressed air
hose before connecting it to the machine.
♦
Choose a suitable hose size from the options
available and connect it to the water outlet on the
pump. For maximum flow with the CP pumps, a
3 in. (76 mm) hose is recommended.
♦
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 100
feet (30 meters), a hose with a minimum internal
diameter of
3
⁄
4
in. (19 mm) should be used. If the
hose length is between 100 and 330 feet (30 and
100 meters), a hose with a minimum internal
diameter of 1 in. (25 mm) should be used.
Methods to prevent freezing
CP 0077 pump is fitted with a muffler that is
connected to the exhaust-air outlet.
Ice formation in the muffler can occur when the
ambient air temperature is 0–10°C (32-50 °F) and
the relative humidity is high.
Take the following action to further counteract the
risk of ice formation:
♦
Use a water separator.
Lubrication
For problem-free operation, continuous lubrication
of the pump is required. Before using and after each
eight hours service, fill the integreated oiler with
recommended oil, at the same time remove the
ejector valve plug and fill the ejector valve with 8
drops of recommended oil, see below.
9800 0556 90c | Original instructions
10
CP 0077
Safety and operating instructions
Summary of Contents for CP 0077
Page 2: ...9800 0556 90c Original instructions 2 CP 0077 ...
Page 69: ...69 9800 0556 90c Istruzioni originali Indice CP 0077 ...
Page 96: ...9800 0556 90c Original instructions 96 CP 0077 ...
Page 97: ...97 9800 0556 90c Original instructions CP 0077 ...
Page 98: ...9800 0556 90c Original instructions 98 CP 0077 ...
Page 99: ...99 9800 0556 90c Original instructions CP 0077 ...
Page 100: ...2013 11 No 9800 0556 90c Copyright Atlas Copco Construction Tools AB KALMAR SWEDEN ...