Maintenance

1.

Keep this unit clean and dry.  Unplug the unit before cleaning.  Clean only the

outside of this unit with a soft, dry cloth; never clean this unit with water or harsh
cleaners.

2.

Aside from the fuses, this device does not contain any user replaceable parts.

If it needs service, take it to a qualified technician.

3.

Fuse Replacement:

This unit must have all energy storing electronics discharged BEFORE

opening;  test for voltage to verify that the unit is safe BEFORE opening.

Remove the screws holding on the front plate.  Slide it up slightly to allow the

bottom plate to slide out.  Using insulated pliers (sold separately), remove, check,
and replace* each fuse as needed.  Reverse the earlier steps to reassemble.

*Replace each fuse 

ONLY

 with another 30 amp, blade-type fuse.

Operation

Warning:  NEVER operate this inverter unless it is properly grounded.

1.

Plug the 115 VAC device(s) you wish to power into the 3-prong AC Receptacles.

See 

FRONT

 above. The appliance(s) must not use more than 1,200 (total) watts

during continuous operation, otherwise it may overload the Inverter.

Caution: Some rechargeable appliances may damage the Power Inverter or the
appliance.  When first using a rechargeable device, check the inverter’s tem-
perature for the first 10 minutes.  If it becomes abnormally hot, do not use this
device with the Inverter.

2.

Flip the Power Switch to the ON position to turn on.  Do not use the appliance

until the power LED illuminates.

3.

Turn on appliance.  If an alarm sound is heard, turn off the appliance.

Caution:  It is recommended that the vehicle be started every hour to recharge
the battery.  Doing this will help prevent any unexpected shutdown of the equip-
ment.  This will also help ensure that there will be enough battery power to start
the vehicle.  Due to the risk of carbon monoxide inhalation (see 

Warning

 # 22 on

page 4), do not run the vehicle’s engine within an enclosed area.

4.

After use, disconnect the appliances and flip the Switch to the OFF position.

FRONT

Outlets

Switch

Power LED

Summary of Contents for Power Systems 93761

Page 1: ...ight 2005 by Harbor FreightTools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE 93761 ...

Page 2: ...area conditions Do not use devices in damp or wet locations Don t expose to rain Keep work area well lighted Do not use electrically pow ered devices in the presence of flammable gases or liquids Specifications M E T I N O I T P I R C S E D r e w o P s u o u n i t n o C s t t a W 0 0 2 1 r e w o P k a e P s t t a W 0 0 2 3 e g a t l o V t u p n I e l b i s s o p s t l o V 5 1 1 1 C D l a n i m o N...

Page 3: ...t all times Do not reach over or across running machines 11 Maintain inverters with care Keep inverters clean for better and safer perfor mance Follow instructions for changing accessories Inspect inverter cords periodically and if damaged have them repaired by an authorized technician 12 Disconnect power Unplug inverter when not in use 13 Avoid unintentional starting Be sure the switch is in the ...

Page 4: ...fans doing so can cause the Inverter to overheat causing a potential fire hazard and or damage to the In verter Leave adequate ventilation space underneath the Inverter as well thick carpets or rugs can obstruct air flow causing the Inverter to overheat 22 A vehicle s engine must never be used in any sealed structure Carbon monoxide is produced during operation and is DEADLY in a closed envi ronme...

Page 5: ...chniques 2 Connect the Battery Cable not included 3 AWG or larger cables recommended lugs to the Positive red and Negative black terminals on the back of the Inverter see BACK above Connect the Ground Cable not included 6 AWG or larger cable recommended lug to the Ground terminal see BACK above Se curely tighten 3 The Power Inverter can be used either while the engine is running or off Con nect th...

Page 6: ...115 VAC device s you wish to power into the 3 prong AC Receptacles See FRONT above The appliance s must not use more than 1 200 total watts during continuous operation otherwise it may overload the Inverter Caution Some rechargeable appliances may damage the Power Inverter or the appliance When first using a rechargeable device check the inverter s tem perature for the first 10 minutes If it becom...

Page 7: ...just the orientation of the inverter to the antenna cables and TV power cord to minimize the interference Also use a shielded antenna cable 6 If the low battery alarm is on all the time try these corrective measures Re charge battery if in poor condition Next check the battery connection You may need to clean the connectors 7 If you are getting a low output voltage try reducing the load to minimiz...

Page 8: ...KU 93761 Page 8 For technical questions please call 1 800 444 3353 Assembly Diagram NOTE Parts are listed and shown for illustration purposes only and are not available individually as replacement parts ...