background image

GeneRal SaFeTY RuleS

 WaRninG!  Read all instructions

 

Failure to follow all instructions listed below may result in serious injury.

  

SaVe THeSe inSTRuCTionS

Work area safety

Keep work area clean and well lit.  

Cluttered or dark areas invite accidents.

Keep children and bystanders away while operating this ultrasonic Cleaner.  

Distractions can cause you to lose control.

personal safety

Stay alert, watch what you are doing and use common sense when operating.  Do 

not use while you are tired or under the influence of drugs, alcohol or medication.  

A moment of inattention while operating may result in serious personal injury.

use safety equipment.  always wear anSi-approved safety goggles.  

Safety 

equipment such as full face shield, work gloves and non-skid safety shoes, 

used for appropriate conditions will reduce personal injuries.

Do not overreach.  Keep proper footing and balance at all times.  

This enables 

better control in unexpected situations.

Tool use and care

Use the correct tool for your application.  

The correct tool will do the job better 

and safer at the rate for which it was designed.

Do  not  use  the  Ultrasonic  Cleaner  if  the  power  switch  will  not  start  and/or 

completely stop the action of this tool.  

Any tool that cannot be controlled with 

the power switch is dangerous and must be repaired.

Store out of the reach of children and do not allow persons unfamiliar with 

the ultrasonic Cleaner or these instructions to operate this tool.  

tools are 

dangerous in the hands of untrained users.

Before  use,  check  for  any  condition  that  may  affect  the  tool’s  operation.    If 

damaged, have the tool repaired before use.  

Many accidents are caused by 

poorly maintained tools.

Do not overload the Ultrasonic Cleaner.  Use this Ultrasonic Cleaner in accordance 

with these instructions and in the manner intended for the particular type of tool, 

taking into account the working conditions and the work to be performed.  

Use of 

the Ultrasonic Cleaner for operations different from those intended could result 

in a hazardous situation.

Disconnect  the  power  cord  plug  from  the  power  source  before  making  any 

adjustments, changing accessories, or storing the Ultrasonic Cleaner.  

Such 

preventive safety measures reduce risk of turning on the product accidentally.  

1.

a.
b.

.

a.

b.

c.

4.

a.

b.

c.

d.

e.

f.

Page

SKU 96904

For technical questions, please call 1-800-444-3353.

Summary of Contents for 96904

Page 1: ...491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Cop...

Page 2: ...the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates a hazardous sit...

Page 3: ...which it was designed Do not use the Ultrasonic Cleaner if the power switch will not start and or completely stop the action of this tool Any tool that cannot be controlled with the power switch is d...

Page 4: ...ls being cleaned Do not overload the Cleaner Tank 1 Fill water to the marked fill line Do not clean multiple objects at once Cleaning more than one object at a time will cause them to bang against one...

Page 5: ...prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resistance path to carry electricity a...

Page 6: ...cords with inadequately sized wire causes a serious drop in voltage resulting in loss of power and possible tool damage See Table A The smaller the gauge number of the wire the greater the capacity of...

Page 7: ...eet 150 Feet 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18 16 14 12 5 1 7 0 18 16 14 12 12 7 1 12 0 18 14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 TABLE A Basedonlimitingthelinevoltagedrop...

Page 8: ...ion section at the beginning of this manual including all text under subheadings therein before set up or use of this product Risk of accidental starting resulting in serious personal injury Turn the...

Page 9: ...k See Figure 1 page 8 When the Power Cord is plugged in the digital display is activated See Figure 2 below TIME AND TEMPERATURE SETTINGS To adjust the timer setting on the Control Panel 9 press 5 onc...

Page 10: ...that the Ultrasonic Cleaner is unplugged from its electrical outlet before performing any inspection maintenance or cleaning procedures Before each use inspect the general condition of the Ultrasonic...

Page 11: ...Part Description Q ty 1 Tank 1 2 Rubber Leg 4 3 Handle 2 4 Heater 2 5 Transducer 6 6 Power Connector 1 7 PCB 1 Part Description Q ty 8 Transformer 1 9 Control Panel 1 10 Cover 1 11 Basket 1 12 Power C...

Page 12: ...of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal a...