INSPECTION, MAINTENANCE, AND CLEANING
1.
WARNING! Make sure the Power Switch (66) of the Steam Press is in its
“OFF” position and the appliance is unplugged from its electrical outlet before
performing any inspection, maintenance, or cleaning procedures.
2.
Before each use, inspect the general condition of the Steam Press. Check for
loose screws, misalignment or binding of moving parts, cracked or broken parts,
damaged electrical wiring, and any other condition that may affect its safe opera-
tion. If abnormal noise or vibration occurs, have the problem corrected before
further use. Do not use damaged equipment.
3.
To clean the Steam Press: Fill the Water Tank (20) with water. Place the
Pressing Pad (79) in the middle of the Ironing Board (58). Place a clean towel
over the Pressing Board and Ironing Board. Set the Temperature Control But-
tons (5) to their highest setting (linen). When the Steam Burst Ready Indicator
Light (83) illuminates, lower the Pressing Board onto the Pressing Pad. Press
the Steam Burst Buttons (36) six times. Allow the Pressing Board to cool. Clean
the Pressing Board with a damp cloth
only. The Ironing Board (84) is removeable
for hand washing only with a mild detergent.
4.
To store the Steam Press: Allow the unit to cool for at least 30 minutes. Lower
the Pressing Board (1) down all the way, and lock it in position with the Lock
Knob (64). Empty the Water Tank (20) completely. Wrap up the Power Cord/
Plug (80), and place it in the cord storage compartment of the unit. Then store
the unit in a clean, dry, safe location out of reach of children and other unautho-
rized people.
SKU 94627 For technical questions, please call 1-800-444-3353 PAGE 14
TROUBLESHOOTING
Problem
Possible Cause
Possible Solution
Unit fails to heat up and steam.
Power Indicator Light does not
illuminate.
1. Unit is not plugged in.
2. Household circuit
breaker/ground fault interrupter
has tripped or blown a fuse.
1. Plug the unit into a working, 120
volt, electrical outlet.
2. Reset circuit breaker/ground fault
interrupter, or replace fuse.
Unit fails to heat up and steam.
Power Indicator Light does illuminate.
1. Auto-shut off has engaged.
2. Water Reservoir is empty.
3. Unit is damaged or
malfunctioning.
1. Refer to “Auto-Shut Off” section on
page x of this manual for instructions.
2. Refill Water Reservoir.
3. Immediately cease using, and have a
qualified service technician check out
the unit.
Steam burst output is weak or
intermittent.
1. Pressing Board needs to be
cleaned.
1. Clean the Pressing Board properly.
5. CAUTION! All maintenance, service, or repairs not mentioned in this