SPECIFICATIONS

Peak Voltage

80 W

Nominal Voltage

12 VDC

Open Circuit Voltage

21.6 VDC

Note:

  Output will decrease as the panel 

gets hotter than room temperature 

(~70° F).  Angle, solar intensity,  

cloud cover and other factors will 

effect output

uNPACkING

When unpacking, make sure that the 

item is intact and undamaged.  If any parts 

are missing or broken, please call Harbor 

Freight Tools at 1-800-444-3353 as soon 

as possible.

INSTALLATION

  Read the ENTIRE IMPORTANT 

SAFETY INFORMATION 

section at the beginning of this 

manual including all text under 

subheadings therein before set 

up or use of this product.

Note:

  For additional information regarding 

the parts listed in the following pages, 

refer to the Assembly Diagram near 

the end of this manual.

Location

Locate the panel where it will receive 

1. 

full, unobstructed sunlight, especially 

during midday.  Nearby trees or tall 

plants will drop debris, requiring the 

panel to be cleaned more frequently.
The installation location for the 

2. 

panels, charge controller/regulator, 

and batteries must be inaccessible 

to children to prevent electric shock.  

Build a childproof enclosure if 

needed.
Install the charge controller/regulator 

3. 

and batteries in a weatherproof 

enclosure with proper ventilation.

Mounting

Mount at a place where there is 

1. 

maximum amount of sunlight. 
Mount where panel is out of children’s 

2. 

reach. 

Mounting hardware is NOT supplied.

Do not drill through aluminum frame. 

a. 

Glass may break.
Devise clamps or a frame to hold 

b. 

Panel. (Not supplied.)

Use semi-flexible bumpers under the 

c. 

Panel. (Not supplied.)
Do not allow the cabling to be 

d. 

exposed to excessive moisture, heat 

or corrosive elements. 

Angle the face of the panel toward 

3. 

true south

1

 according to the chart that 

follows:

Latitude  Solar Panel Angle 

0-4° 

10° 

5-20° 

La 5°

21-45° 

La 10°

46-64° 

La 15°

65° or more 80° 

Wiring

Note:

 Only a licensed electrician and 

a licensed building contractor can 

safely design and implement a grid 

tie-in system.  Any grid tie-in system 

must meet all applicable building 

and electrical codes, and must meet 

1

 Angle towards true north if installed in 

southern hemisphere.

Summary of Contents for 66369

Page 1: ...l rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manu...

Page 2: ...t symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety ale...

Page 3: ...s rated output Increase output ratings by 25 when determining component required voltage and amperage ratings Refer to Section 690 8 of the National Electrical Code for an additional multiplying facto...

Page 4: ...vice Precautions Before service maintenance or 1 cleaning Dry solar panels and outdoor a wiring thoroughly while wearing electrically insulated gloves Cover all solar panels with an b opaque cover suc...

Page 5: ...more frequently The installation location for the 2 panels charge controller regulator and batteries must be inaccessible to children to prevent electric shock Build a childproof enclosure if needed...

Page 6: ...s Do not use damaged solar panel If wiring insulation is damaged or weathered glass is cracked or housing is opened have the problem corrected before further use Note It is normal to see up to 20 degr...

Page 7: ...to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly o...

Reviews: