SETUP

14. 

Do not operate the power tool near flammable 

materials. Sparks could ignite these materials.

15. 

Do not use accessories that require liquid 

coolants. Using water or other liquid coolants 

may result in electrocution or shock.

16. Maintain labels and nameplates on the tool.  

These carry important safety information.  

If unreadable or missing, contact 

Harbor Freight Tools for a replacement.

17. Avoid unintentional starting.  

Prepare to begin work before turning on the tool.

18. Do not depress the spindle lock when 

starting or during operation.

19. Do not leave the tool unattended when it is plugged 

into an electrical outlet.  Turn off the tool, and 

unplug it from its electrical outlet before leaving.

20. Use clamps (not included) or other practical 

ways to secure and support the workpiece to 

a stable platform.  Holding the work by hand 

or against your body is unstable and may 

lead to loss of control and personal injury.

21. This product is not a toy.  

Keep it out of reach of children.

22. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 

close proximity to heart pacemaker could cause 

pacemaker interference or pacemaker failure.  

In addition, people with pacemakers should: 

• Avoid operating alone. 

• Do not use with power switch locked on. 

• Properly maintain and inspect 

to avoid electrical shock. 

• Properly ground power cord.  Ground Fault Circuit 

Interrupter (GFCI) should also be implemented 

– it prevents sustained electrical shock.

23. WARNING: Some dust created by power sanding, 

sawing, grinding, drilling, and other construction 

activities, contains chemicals known [to the State 

of California] to cause cancer, birth defects or 

other reproductive harm.  Some examples of these 

chemicals are: 

• Lead from lead-based paints 

• Crystalline silica from bricks and cement or 

other masonry products 

• Arsenic and chromium from 

chemically treated lumber 

Your risk from these exposures varies, 

depending on how often you do this type of work.  

To reduce your exposure to these chemicals: work 

in a well ventilated area, and work with approved 

safety equipment, such as those dust masks that are 

specially designed to filter out microscopic particles.  

(California Health & Safety Code § 25249.5, 

et seq.

)

24. WARNING: Handling the cord on this product will 

expose you to lead, a chemical known to the State 

of California to cause cancer, and birth defects or 

other reproductive harm. Wash hands after handling.  

(California Health & Safety Code § 25249.5, 

et seq.

)

25. The warnings, precautions, and instructions 

discussed in this instruction manual cannot 

cover all possible conditions and situations 

that may occur.  It must be understood by the 

operator that common sense and caution are 

factors which cannot be built into this product, 

but must be supplied by the operator.

Summary of Contents for 60713

Page 1: ......

Page 2: ...tuation which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMPORTANT SAFETY INFORMATION General Power Tool Safety Warnings Read all safety warnings and instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The term powe...

Page 3: ...ny adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury 5 Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations 6 Dress properly Do not wear loose clothing or jewelry Keep your hair clothing and gloves away from moving...

Page 4: ...wire brush for loose or cracked wires If power tool or accessory is dropped inspect for damage or install an undamaged accessory After inspecting and installing an accessory position yourself and bystanders away from the plane of the rotating accessory and run the power tool at maximum no load speed for one minute Damaged accessories will normally break apart during this test time 7 Wear personal ...

Page 5: ... alone Do not use with power switch locked on Properly maintain and inspect to avoid electrical shock Properly ground power cord Ground Fault Circuit Interrupter GFCI should also be implemented it prevents sustained electrical shock 23 WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause c...

Page 6: ...dges or bouncing have a tendency to snag the rotating accessory and cause loss of control or kickback 5 Do not attach a saw chain woodcarving blade or toothed saw blade Such blades create frequent kickback and loss of control Safety Warnings Specific for Grinding and Abrasive Cutting off Operations 1 Use only wheel types that are recommended for your power tool and the specific guard designed for ...

Page 7: ...rush even during ordinary operation Do not overstress the wires by applying excessive load to the brush The wire bristles can easily penetrate light clothing and or skin 2 If the use of a guard is recommended for wire brushing do not allow any interference of the wire wheel or brush with the guard Wire wheel or brush may expand in diameter due to work load and centrifugal forces Vibration Safety T...

Page 8: ...ectrically live terminal See 3 Prong Plug and Outlet 3 The tool must be plugged into an appropriate outlet properly installed and grounded in accordance with all codes and ordinances The plug and outlet should look like those in the preceding illustration See 3 Prong Plug and Outlet Double Insulated Tools Tools with Two Prong Plugs Outlets for 2 Prong Plug 1 Tools marked Double Insulated do not re...

Page 9: ... Table A RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 240 VOLT NAMEPLATE AMPERES at full load EXTENSION CORD LENGTH 25 50 75 100 150 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18 16 14 12 5 1 7 0 18 16 14 12 12 7 1 12 0 18 14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 Based on limiting the line voltage drop to five volts at 150 of the rated amperes Symbology Double Insulated Ca...

Page 10: ...manual including all text under subheadings therein before set up or use of this product TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Make sure that the Power Switch is in the off position and unplug the tool from its electrical outlet before performing any procedure in this section Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagr...

Page 11: ... the Collet Nut counterclockwise until it stops rotating and locks into place 2 Continuing to press down on the Lock Button use the supplied Wrench to loosen the Collet Nut Continue to remove the Collet Nut by hand 3 Remove the Collet by pulling it straight out of the shaft Installing Collet and Accessory 1 Insert the Collet fully into the shaft and replace the Collet Nut loosely 2 Insert the desi...

Page 12: ...ke sure that the Power Switch is in the O OFF position then plug in the tool 3 Press the Power Switch to the I ON position to start the tool 4 Allow the tool to come up to full speed before touching the work material 5 Keep heavy pressure off of the tool when operating Allow the tool to do the work 6 Move the tool in a uniform pattern up and down or side to side while sanding to ensure even sandin...

Page 13: ...roved safety goggles and NIOSH approved dust mask respirator while blowing dust out of motor using compressed air 3 Eliminate use of extension cord If an extension cord is needed use one with the proper diameter for its length and load See Extension Cords in GROUNDING section Tool does not grind sand or brush effectively 1 Accessory loose 2 Accessory may be damaged worn or wrong type for the mater...

Page 14: ...IBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL RE...

Page 15: ...ndividually as replacement parts Main Unit Parts List and Assembly Diagram Part Description Qty 1 Right Cover 1 2 Screw 2 9x15mm 6 4 Carbon Brush 2 5 Collet Nut 1 6 Collet 2 7 Front End Nut 1 8 Bearing 698ZZ 1 9 Lock Button 1 10 Spring 1 11 Board 1 12 Motor 1 Part Description Qty 13 Stator 1 14 Bearing 602ZZ 1 16 Left Cover 1 17 Power Switch 1 18 Screw 4x16mm 2 19 Power Cord Clip 1 20 Speed Contro...

Page 16: ... the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and...