Cheyenne Sol Nova Operating Instructions Manual Download Page 10

25

EN

Getting the SOL Nova ready 
for operation

ATTENTION

Damage from condensate

If the SOL Nova is exposed to significant 
variation  in  temperature,  e.g.  during 
transport,  condensate  can  form  inside 
which can damage the electronics.

 

!

Ensure  that  the  SOL  Nova  has 
reached 

ambient 

temperature 

before  using  it.  If  it  was  exposed  to 
high  temperature  fluctuations,  wait 
for  at  least  3  hours  for  every  10°C 
of  temperature  di

ff

erence  before 

putting it into operation.

 

!

Only  use  the  SOL  Nova  at  ambient 
temperatures of +10 to +35°C.

5.1 

Disinfecting equipment

ATTENTION

Damage to drive caused by fluid

If disinfectant gets inside the drive, this 
can corrode the electrical and mechan-
ical components.

 

!

Never immerse the drive in disinfectant.

ATTENTION

Product  damage  caused  by  non-

approved disinfectants

Disinfectants  that  are  not  compatible 
with  the  materials  of  the  product  can 
damage its surface.

 

!

Always  use  disinfectants  that  are 
approved,  i.e.  that  comply  with 
stipulations in your country.

 

!

Note  the  list  of  recommended 
disinfectants  in  chapter  “Material 
compatibilities” on page

 

29.

 

!

Switch o

ff

 the power supply to the SOL 

Nova.

 

!

Check  if  the  SOL  Nova  has  been 
contaminated badly by the return flow 
of  ink  or  bodily  fluids.  In  such  cases, 
perform the steps described in chapter 
“Cleaning  and  maintaining  the  SOL 
Nova” (see Page

 

29).

 

!

Wipe  down  the  connecting  cables,  the 
drive  and  the  handle  with  a  soft  cloth 
dipped in disinfectant.

5.2 

Replacing the safety cartridge

 WARNING

Risk of injury from needles

Injuries  caused  by  contaminated 
needles from the safety cartridges can 
lead to the transmission of disease.

 

!

Always  use  genuine  Cheyenne 
safety  cartridges  for  the  SOL  Nova. 
The  installed  safety  membrane  on 
these  safety  cartridges  prevents  the 
ingress of ink into the drive, and also 
prevents  pathogens  from  entering 
the appliance.

 

!

Never  hold  the  safety  cartridge  by 
its tip.

 

!

Switch  o

ff

  the  SOL  Nova  before 

changing the safety cartridge.

 

!

Ensure  that  when  removing  a  used 
safety cartridge, no ink remnants can 
run into the handle.

 

!

Never  push  the  needles  out  of 
the

 

safety cartridge.

 

!

Check  during  the  removal  of  a  used 
safety cartridge that the needles are 
completely  retracted  into  the  safety 
cartridge.

Cheyenne SOL Nova

Summary of Contents for Sol Nova

Page 1: ...sung Operating instructions Gebruiksaanwijzing Instructions Istruzioni per l uso Instrucciones de uso Manual de instruções Oδηγίες Opskrift Bruksanvisning Ohjeet Instrukcja obsługi Instrukce Navodila nt pl za uporabo Utasítás инструкции 说明 ...

Page 2: ...1 Cheyenne SOL Nova 1 1 2 3 4 5 ...

Page 3: ...gem Pega Motor Cabo de conexão Adaptador de cabo EL Safety cartridge Λαβή Μοτέρ Καλώδιο σύνδεσης Αντάπτορας καλωδίου DA Safety cartridge Gribestykke Drev Tilslutningskabel Kabeladapter SV Säkerhetspatron Grepp Motor Strömkabel Kabeladaptrar FI Safety cartridge turvapatruuna Kahvaosa Moottori Liitäntäjohto Johtosovitin PL Kartridż bezpieczeństwa Uchwyt Napęd Kabel zasilający Adaptery do kabla CS Be...

Page 4: ...cting the power unit 26 5 4 Fitting the protective hose 27 5 5 Checking equipment 28 6 Using the SOL Nova 28 6 1 Setting the needle protrusion 28 6 2 Setting the piercing frequency 29 6 3 Loading with ink 29 7 Cleaning and maintaining the SOL Nova 29 7 1 Material compatibilities 29 7 2 Disinfecting surfaces 30 7 3 Cleaning surfaces 30 7 4 Cleaning handle in an ultrasonic bath 30 7 5 Sterilising ha...

Page 5: ... notices Warning notices draw attention to the risk of personal injury and damage to materials and are structured as follows SIGNAL WORD Type of hazard Consequences Remedy Element Meaning Indicates a risk of injury Signal word Specifies the severity of the hazard see following table Type of hazard Gives the type and source of the hazard Conse quences Describes potential conse quences of non compli...

Page 6: ... switch it off and place it safely so that it cannot roll away and fall to the ground Note the technical data quoted in these operating instructions and comply with operating transport and storage conditions see Page 24 Hand over the SOL Nova to a specialist retailer for inspection if it exhibits any external signs of damage or if it does not function in the usual manner 2 3 Important hygiene and ...

Page 7: ...attooed Scars in the area that shall be tattooed Systemic infections and infectious dis eases e g Hepatitis type A B C D E or F HIV infection or acute local skin infections e g herpes rosacea During chemotherapy radiotherapy or high dosage corticosteroid therapy recommendation from four weeks be fore the start until four weeks after the end of the therapy Up to twelve months after a plastic sur ge...

Page 8: ...nowledge of the risks and side effects see chapters Contra indications on page 22 and Side effects on page 22 2 7 Intended use The SOL Nova is a professional tattooing machine for the application of tattoos to the human skin in dry clean and smoke free environments and under hygienic conditions It must be prepared used and maintained in the manner described in these operating instructions In parti...

Page 9: ... 5 to 12 6 V DC Power intake 3 W Start up current Max 2 5 A for max 200 ms Piercing frequency 25 to 150 Hz Stroke 3 5 mm Needle protrusion 0 to 4 0 mm Electrical connection 3 5 mm jack Drive Brushless DC motor Operating mode Continuous operation Diameter 33 mm Length 102 mm Weight Approx 150 g Sound emission pressure level Max 70 dB A Total vibration Max 2 5 m s 4 2 Operating conditions Ambient te...

Page 10: ...ecommended disinfectants in chapter Material compatibilities on page 29 Switch off the power supply to the SOL Nova Check if the SOL Nova has been contaminated badly by the return flow of ink or bodily fluids In such cases perform the steps described in chapter Cleaning and maintaining the SOL Nova see Page 29 Wipe down the connecting cables the drive and the handle with a soft cloth dipped in dis...

Page 11: ...the safety cartridge clockwise through approx 45 As you rotate it several locating points will engage audibly until the safety car tridge is firmly locked into position Check that the safety cartridge is firmly seated To remove the safety cartridge turn it anti clockwise and remove it from the handle 5 3 Connecting the power unit CAUTION Risk of short circuits If cable or cable connection is visib...

Page 12: ... of the connecting cable supplied to the connection on the drive unit of the SOL Nova Plug the jack of the connecting cable fully into the output socket on the power unit If you are using an third party power unit connect up its terminals correctly as described in the operating instructions of the third party power unit Connect the power unit to the mains power supply Cover the Power Unit or the t...

Page 13: ...pecialist retailer 6 Using the SOL Nova 6 1 Setting the needle protrusion CAUTION Risk of injury from excessive protrusion of needle A large needle protrusion permits a deep piercing depth If needle protrusion and piercing depth are excessive this can damage the subcutaneous layer Start with just a short length of needle protruding Switch on the power Adjust the needle protrusion while the SOL Nov...

Page 14: ... of the safetycartridgeinthedesiredcolourofink for 2 to 3 seconds with the unit running Avoid contact with the ink container The ink is picked up by the needles Alternatively the ink can be filled into the opening on the safety cartridge using a sterile pipette 7 Cleaning and maintaining the SOL Nova CAUTION Risk of short circuits If components of the SOL Nova are dis mantled and cleaned while sti...

Page 15: ... soft cloth dipped in a cleaning agent or a disinfectant Clean inaccessible surfaces e g the thread of the drive unit with a soft bristled nylon brush 7 4 Cleaning handle in an ultrasonic bath If the handle is severely soiled Use the cleaning agent Tickomed 1 or Tickopur R33 from manufacturer Dr H Stamm GmbH in accordance with the manufacturer s instructions Make sure that a pH value of 7 is not e...

Page 16: ...able regulations for used electronic equipment If necessary consult the specialist retailer or the responsible authorities to learn about applicable regulations Provide containers at the workplace for legislation compliant disposal of contaminated components Dispose of used or defective safety cartridges in a sharps container safety box in accordance with the regulations applicable in your country...

Page 17: ...al and workmanship for the product For the safety cartridges we guarantee sterility until the expiry date on the packaging providing that the packaging is sealed and undamaged and that the transport and storage conditions have been complied with For complaints relating to safety cartridges please advise us of the batch number printed on the label We do not provide warranty cover in respect of the ...

Page 18: ...ine directive Basic Machine directive requirements used or complied with 1 1 2 1 1 3 1 1 5 1 1 6 1 2 2 1 3 1 1 3 2 1 3 3 1 3 4 1 3 7 1 5 1 1 5 2 1 5 4 1 5 5 1 5 6 1 5 8 1 5 9 1 5 11 1 5 13 1 6 1 1 6 3 1 7 1 1 1 7 4 1 7 4 1 1 7 4 2 1 7 4 3 2 1 2 1 1 2 1 2 2 2 1 2 2 1 1 The special technical documentation according to Appendix VII Part B has been established The person authorized to compile the tech...

Page 19: ...0 3 3 ed 2 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic current emissions Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection CISPR 14 2 1997 AMD1 2001 AMD2 2008 CISPR 14 1 2005 AMD1 2008...

Reviews: