LIMIT SWITCHES AND OBSTACLE DETECTION
Obstacle detection in ASCENT
Obstacle detection in ascent is enabled only after both the limit switches have been set.
In the event of obstacle detection in ascent, the motor will stop without making any
movements backwards.
Obstacle detection in DESCENT
In the event of obstacle detection in descent, with the super-sensitivity feature on, the
motor stops and makes a backwards safety movement.
20
DOWN
UP
RESTORING THE ORIGINAL CONFIGURATION
To restore the original motor configuration perform the procedure as described below:
- Connect both the brown and black motor wires under the same switch, e.g. UP.
PLEASE NOTE: recovery of the default configuration will delete the limit switches
and disabling the super-sensitivity.
- Press the UP button for at least 2 seconds.
- Disconnect and then restore the original control switch electrical connections (see
page 13).
1- Brown
2 - Black
3 - Blue
4 - Yellow-green