SYSTEM STATUS
Automatic
08:00/17:00
Brightness: 0135
Temperature: 20 °C
Thresh./Main menu
Quick start
32
BRIGHTNESS:
Brightness bar
Temperature bar
Brightness hysteresis
frame
Twilight threshold
Temperature
intervention threshold
Brightness level
Motor command
Effect
Above the hysteresis frame
DOWN
Less light
Below the hysteresis frame
UP
More light
Within the hysteresis frame
No command or STOP (if in
movement)
Mantains the current brightness level
Below the twilight threshold*
DOWN (blinds/venetian blinds)
UP (awnings)
)**
until they are completely closed
Close the blinds/awnings completely
Disable the automation
Disable the temperature sensor
(if active)
*
optional
*
*
The motor automatically sets the movement based on the type of device memorised
SUMMER (sun)
Temperature level
Motor command
Effect
Above the threshold
DOWN
Less light
Less heat
Blocks light sensor management, if active
Below the threshold
No command
Maintains the current temperature level set
Light sensor is managed by settings
WINTER (snowflake)
Temperature level
Motor command
Effect
Above the threshold
UP
More light
More heat
Blocks light sensor management, if enabled
Below the threshold
No command
Maintains the current temperature level set Light
sensor is managed by settings
To enable the automation again after complete closing, the blinds/venetian blind must
be opened so that the sensor is again exposed to light up to a point that falls within the
hysteresis frame.
TEMPERATURE:
Management of events linked to temperature is associated with the Season Option setting
(see Programming/Season Option page 35).
In AUTOMATIC mode it is always possible to control the motor manually with the A, B and
C buttons. This movement disables automatic operation for a time that may be set by the
user (see “Setting the Automatic Disable time”, page 36). During this time the “red hand”
symbol is displayed on the screen.