Smart Dry Contact Switch 7 - Operating Instructions
15
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default value: 2 clicks
→
2
Parameter
Number
Size
Parameter Name
Default
Value
Description
44
1
G1_ASS_VALUE
101
The value used to control G1 association group.
Parameters Values Min: 0 Max: 102
Value
Description
0
OFF
1-99
specific diming value
100
ON
101
propagate (
output 1 status to the associated device
)
102
toggle remote (
change status ON/OFF of associated devices
)
Parameter
Number
Size
Parameter Name
Default
Value
Description
45
1
G2_ASS_VALUE
101
The value used to control G2 association group.
Parameters Values Min: 0 Max: 102
Value
Description
0
OFF
1-99
specific diming value
100
ON
101
propagate (
output 1 status to the associated device
)
102
toggle remote (
change status ON/OFF of associated devices
)
Parameter
Number
Size
Parameter Name
Default
Value
Description
50
4
DIMMING_TIME
5
Fade On/Off time in second used to control device in
dimming group
Parameters Values Min: 0 Max: 3600
Value
Description
0-3600
Specific time expressed in seconds