Smart Dry Contact Switch 7 - Operating Instructions
7
Device Control
Smart Dry Contact Switch 7 can turn ON and OFF the load by using an external switch, or from remote through a
controller.
Controlling the device by External Switches
For the operation of the device within the Z-Wave
™
network and controlling the loads connected to the device, control
actions are performed on the external switches.
The
CONTROL ACTIONS
are
EVENTS
executed on
EXTERNAL SWITCHES
connected to the Line Signal terminal
of the device which can be
Clicks, Hold Down and Up
.
Event
Type of switch
Actions on the switch
Click
Momentary switch
(
button
)
Press briefly & Release
(
when pressed it autonomously returns to the initial position
)
Toggle Switch
(
bistabile
)
Press & Release
(
a single click means one single flip of the switch
)
MultiClick=
n
clicks
Momentary switch
Sequence of consecutive
n
clicks
Toggle Switch
Hold Down
Momentary switch
Press longer than click.
After a Hold Down always follows an UP event.
Up
Momentary switch
Release.
The event applies only if there has been a previous Hold Down event.
Since the device supports Central Scene Notification all the events described in the table will be notified with a Central
Scene Notification Report to the Lifeline. The events that trigger a Central Scene Notification Report can be customized
with the configuration parameter in the Central Scene Notification Parameter section.
Controlling the device by a Z-Wave
™
controller
The device can be controlled by any Z-Wave
™
/ Z-Wave Plus
™
certified controller available in the market.
In the figure below, are represented a couple of examples of
control panel interfaces
that show how the device will
appear once included into the Gateway.