Chemin'Arte Oxford 119 Installation And User Instruction Manual Download Page 9

Maintenance   

·

 

WARNING

: Before any maintenance and/or cleaning the exterior of the heater, 

disconnect the heater form the power supply and leave heater cooled off. 

·

 

The heater uses an electronically controlled LED system to create the flame effect 
therefore no parts need to be replaced. Under no circumstances should the heater 
be serviced by anyone other than a qualified electrician.   

 

Safety Cut-out 

·

 

This heater is fitted with a safety cut-out which will operate if the heater 
overheats (e.g. Due to blocked air vents). For safety reasons, the heater will NOT 
automatically reset. 

·

 

To reset the heater, disconnect the heater from the mains supply for at least 15 
minutes. Reconnect the supply to the mains and switch on the heater. 
 

Care and Cleaning 

·

 

Always  disconnect  the  heater  from  mains  supply  and  allow  cooling  before  any 
cleaning operation. 

·

 

Trim parts may be cleaned using a clean, damp cloth. Never use abrasive cleaners 
and chemical agents as damage may occur to the finish.   

 

Technical Specification   

·

 

Supply: 220-240V~ 50Hz   

·

 

Rated power: 2000W   

·

 

Lighting: LEDs

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Oxford 119

Page 1: ...www cheminarte com INSTALLATION AND USER INSTRUCTION GUIDE FOR OXFORD ELECTRIC FIREPLACE ...

Page 2: ...n these instructions From time to time check the cord for damages Never use the appliance if the cord or any part of the appliance shows any signs of damage If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING In order to avoid overheating do not cover or obstruct the heater in any way Do not use t...

Page 3: ...tinuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in re...

Page 4: ...e minimum distances must be observed Make sure the opening dimensions of mantel are at least 595mm width and 435mm height Make sure the distance from the rear of heater to the wall is at least 100mm Make sure the distances from the left right and top of heater to the wall are at least 100mm Inset the heater carefully into the opening of mantel Fix the heater securely on the hearth by supplied brac...

Page 5: ...ual Operation NOTE The heater only starts working if the set temperature is higher than the ambient room temperature Remote Operation NOTE The heater should be powered on using the ON OFF switch before it can be operated using remote control Heater powered off Heater powered on set to standby mode Press to switch the flame effect ON OFF Press and hold to toggle between 5 different flame dim levels...

Page 6: ...y sliding the cover down and insert the batteries noting the polarity indicated in the battery compartment Keep batteries out of reach of children Remote control operations are identical to the functions on the control panel The remote control must be point directly at the sensor on control pad ...

Page 7: ...e temperature in the timer mode The default set temperature is 20 NOTE The heater only starts working when the set temperature is higher than the room temperature Press the or key to set the temperature which ranges from 15 to 30 After the temperature setting has been completed the display flashes about 5 seconds then shows the room temperature Setting timer Up to 10 different timer settings can b...

Page 8: ... blinking Press the or key to set the temperature Press the TIMER SET key to continue with the timer setting or press the OK key to confirm the setting Viewing the timer setting Press the TIMER SET key Press the or key to check the power on time of the set timers one by one To check the power off time press the key Press the or key to check the power off time of the set timers one by one To delete...

Page 9: ...h a safety cut out which will operate if the heater overheats e g Due to blocked air vents For safety reasons the heater will NOT automatically reset To reset the heater disconnect the heater from the mains supply for at least 15 minutes Reconnect the supply to the mains and switch on the heater Care and Cleaning Always disconnect the heater from mains supply and allow cooling before any cleaning ...

Page 10: ...e At nominal heat output elmax 0 000 KW Type of heat output room temperature control select one At minimum heat output elmin 0 000 KW single stage heat output and no room temperature control no In standby mode elSB 0 000 W Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic room tempera...

Page 11: ...ssible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the produce was purchased They can take this product for environmental safe recycling ...

Reviews: