Supported Configurations
1.1 Single Aisle (AN-PN)
1. Use interpedestal coax cable to connect RX3 of AN to RX5 of PN.
2. Use interpedestal coax cable to connect RX4 of AN to RX6 of PN.
3. Use interpedestal network cable to connect “Interpedestal OUT” of AN to
“Interpedestal IN” of PN.
4. Connect 12 VDC to the WRTZ reader using power supply system.
Figure 1:
Pedestal / Array Layout: Standard Single Aisle
1.2 Dual Aisle (other Pedestal combinations are possible)
1. Ensure that the correct RFID Arrays are facing
each other. While physically mounting kit
hardware or pedestal, ensure that one of the
“standard” layouts is achieved. (RX Map can be
reversed when first Active should be aisle right.)
2. Use interpedestal coax cable to connect
RX3 of AN to RX5 of AP.
3. Use interpedestal coax cable to connect
RX4 of AN to RX6 of AP.
Figure 2:
Standard Dual Aisle (NA-PA-PN or NP-AP-AN)
4. Use interpedestal coax cable to connect RX3 of AP to RX5 of PN.
5. Use interpedestal coax cable to connect RX4 of AP to RX6 of PN.
6. Use interpedestal network cable to connect “Interpedestal OUT” of AN to “Interpedestal IN” of AP.
7. Use interpedestal network cable to connect “Interpedestal OUT” of AP to “Interpedestal IN” of PN.
8. Connect 12 VDC to the WRTZ reader using power supply system.
1.3 Multi-Aisle (AN-AP-AP-AP-AP-PN)
Figure 3:
Pedestals in the Standard Multi-Aisle layout
1. Use interpedestal coax cable to connect RX3 of AN to RX5 of AP.
2. Use interpedestal coax cable to connect RX4 of AN to RX6 of AP.
3. Use interpedestal coax cable to connect RX3 of AP to RX5 of next AP.
4. Use interpedestal coax cable to connect RX4 of AP to RX6 of next AP.
5. Use interpedestal coax cable to connect RX3 of next AP to RX5 of PN.
6. Use interpedestal coax cable to connect RX4 of next AP to RX6 of PN.
7. Use interpedestal network cable to connect “Interpedestal OUT” of AN to “Interpedestal IN” of AP.