4.0
Overview of CDT-2000
5
4.1 LCD Display
Low Battery Indicator
Units of Measure Indicators
Each time the MODE key is pressed the units will change.
On-Target Indicator
Memory Indicators
8.8.8
.8.8
m
ax
m
in
mem
rpm
m/m
in
ft/m
in
in/m
in
MEM
MODE
➊
➍
MEM
➌
MODE
rpm
rpm
m/min
m
ft/min
ft
in/min
in
➋
max min mem
1
2
3
4
6.0
MEASURING RPM
6.1 Contact Operation - RPM
1. Install the Slide-on Contact Adapter.
2. Select either the Cone Tip Adapter or the Funnel Tip Adapter for
contact with the rotating shaft.
Note: The Funnel Tip is part of the Surface Speed Wheel.
3. Slide the selected adapter over the shaft
of the instrument. Be sure to align the
pin on the side of the shaft with the slot
in the adapter. Push on securely.
4. Select the Contact RPM mode by pressing the
key until the following symbol is shown on the LCD Display.
5. Position the adapter carefully so that it contacts the center of the
rotating shaft. Apply enough pressure to eliminate any slip.
6. Press
and
hold the Measure key to take measurements.
7. Release the Measure key prior to removing the instrument from the
rotating element. The Last reading will be retained on the display.
8
M
ODE
MEM
ma
x
m
in
m
em
rp
m
m/m
in
ft/m
in
in
/m
in
8.8.8
.8.8
SLOT
PIN
RPM
MODE