background image

1.0

INTRODUCTION

The CDT-2000 Digital Tachometer combines the best features of contact
and non-contact tachometers for measuring rotational speed, surface speed
and length. 

When used in the 

non-conta

ct operating mode, a small piece of reflective

tape is applied to the rotating element (wheel, shaft, etc.). The CDT-2000
uses a visible LED light source to accurately measure the RPM from up to
14” (350 mm) away from the “target”. In the

contact 

operating mode, the

speed is sensed using one of the contact adapters supplied with the instru-
ment.

In applications where surface speed or linear speeds are to be measured,
the universal wheel is used for direct readout of feet/min, meters/min or
inches/min, as selected by the user. The CDT-2000 can also be used to
measure the accumulated total of continuously running material such as
paper, wire/yarn being wound on a spool, or for checking the calibration
of on-line counters and totalizer devices.

1.1 Applications

2

Contact RPM

— Used to measure the speed of rotating

motors, shafts, pulleys, gears, etc.

Non-Contact RPM 

— Used when contact measurement

is not possible due to access space restrictions, safety 
concerns, etc.

Linear Speed and Length

— Used to measure the

linear speed or length of moving surfaces, such as

conveyor belts, printed materials, webs of fabric

or paper, etc.

8.0

MEMORY SYSTEM

The CDT-2000 is supplied with a built-in memory
system which stores the 

last

measurement, 

the

maximum

measurement and the 

minimum

measurement which occurred during a measuring
period. A measuring period is the interval of time
while the Measure key is depressed. The stored
values are retained in memory even when the
power turns off (auto power off). To recall the
stored values after auto power off:

1.  Press the Measure key to turn the power on
2.  Press the MEM key to recall the desired value

The Memory key accesses the CDT-2000’s built-in memory.
Each time the  MEM  key is pressed the values stored in 

memory will be recalled to the display in the sequence listed below. The
appropriate memory indicator will be shown together with the recalled
value on the display. 

Note: 

When the batteries are removed, the values stored in memory will 

be lost. 

11

8.8.8.8.8

max min mem

rpm
m/min
ft/min
in/min

mem

mem

max
mem

min
mem

max
mem

min
mem

MEM

MAX

MIN

LAST

MEM

min

rpm

max

mem

t

Summary of Contents for CDT-2000

Page 1: ...gh Decimal Point Automatic Memory System Maximum minimum and last reading retained in memory for the life of batteries Measurement System Non Contact Visible LED light beam Contact Contact adapter Engineering units RPM RPM Surface Speed Feet min inches min and meters min Length Feet inches meters Sensing Distance Up to 14 inches 350mm Display Update Time 0 5 seconds or one measuring period Auto Po...

Page 2: ... RPM Used when contact measurement is not possible due to access space restrictions safety concerns etc Linear Speed and Length Used to measure the linear speed or length of moving surfaces such as conveyor belts printed materials webs of fabric or paper etc 8 0 MEMORY SYSTEM The CDT 2000 is supplied with a built in memory system which stores the last measurement the maximum measurement and the mi...

Page 3: ...al Heavy Duty Surface Speed Wheel with set screw mounting 5 Store the instrument in its carrying case when it is not in use 3 7 0 MEASURING SURFACE SPEED OR LENGTH 1 Install the Slide on Contact Adapter 2 Slide the Surface Speed Wheel over the shaft of the instrument Be sure to align the pin on the side of the shaft with the slot in the adapter Push on securely 4 Select the desired units of measur...

Page 4: ...ment assistance 4 Press and hold the Measure key to begin taking measurements The On Target indicator will be displayed on the LCD if the instrument is properly aimed at the target reflective tape 5 Release the Measure key prior to removing the instrument from the target The last reading will be retained on the LCD display Hints for Non Contact Measurements 1 The non reflective area should be larg...

Page 5: ...he Funnel Tip is part of the Surface Speed Wheel 3 Slide the selected adapter over the shaft of the instrument Be sure to align the pin on the side of the shaft with the slot in the adapter Push on securely 4 Select the Contact RPM mode by pressing the key until the following symbol is shown on the LCD Display 5 Position the adapter carefully so that it contacts the center of the rotating shaft Ap...

Page 6: ...min ft min in min m min m ft in ft min in min MODE RPM Non Contact RPM Contact METERS MIN FEET MIN INCHES MIN INCHES FEET METERS M E A S U R E 5 0 INSTALLING BATTERIES 1 Open the battery compartment by pulling down on the tab located at the top of the battery cover 2 Remove the battery cover 3 Insert two 2 AA batteries making sure that the polarity of the two batteries matches the illustration eng...

Page 7: ...ECTROMATIC CDT 2000 Digital Tachometer Operating Instructions ELECTROMATIC E Q U I P M E N T C O I N C 600 Oakland Ave Cedarhurst NY 11516 U S A TEL 516 295 4300 FAX 516 295 4399 CHECK LINE INSTRUMENTS Operating Manual ...

Reviews: