CHD Elektroservis TPE-1 Owner'S Manual Download Page 9

Tone Parameters Editor 

Tone Parameters Editor 

Tone Parameters Editor 

Tone Parameters Editor & Controller

& Controller

& Controller

& Controller  

        Owner’s Manual

Owner’s Manual

Owner’s Manual

Owner’s Manual    

Model TPE

Model TPE

Model TPE

Model TPE----1 / BIOS ver. 1.00

1 / BIOS ver. 1.00

1 / BIOS ver. 1.00

1 / BIOS ver. 1.00     

 

 

 

Copyright © 2018 CHD Elektroservis.  All rights reserved.  

No part of this publication may be reproduced in any form without the written permission of CHD Elektroservis.

 

9

99

9

 
 

4

44

4    BASIC 

OPERATION

BASIC OPERATION

BASIC OPERATION

BASIC OPERATION    

 

After all necessary data are loaded to SAVVY, it is prepared for normal operation. All functions of the editor can 
be controlled by buttons on the front panel of the device. 

 

4.1

4.1

4.1

4.1    INITIALIZATION 

SEQUENCE

INITIALIZATION SEQUENCE

INITIALIZATION SEQUENCE

INITIALIZATION SEQUENCE    

 

When the SAVVY is switched on, the reset sequence is executed. During this 
sequence, display indicates the actual operational system and its versions. 

The communication is set automatically to 

 direction indicated by 

green LED 

 and the display shows number of the actually active tone 

.  

 

4.2

4.2

4.2

4.2    COMMUNICATION 

DIRECTION

COMMUNICATION DIRECTION

COMMUNICATION DIRECTION

COMMUNICATION DIRECTION    

 

SAVVY can only work in one direction

only work in one direction

only work in one direction

only work in one direction in real time. It can either transfer data from a controller to an instrument 

or from an instrument to a controller, not

not

not

not in both directions simultaneously!

simultaneously!

simultaneously!

simultaneously!  

To set the communication direction: 

1. 

To change the communication direction press 

 button 

.

.

.

.

 

2. 

The actual direction is indicated by two LEDs – green LED 

 for 

 direction or yellow LED 

 for 

 direction. 

    
    

Figure 4

Figure 4

Figure 4

Figure 4    ---- Controller to instrument communication direction

 Controller to instrument communication direction

 Controller to instrument communication direction

 Controller to instrument communication direction    

 

 

 

Figure 5 

Figure 5 

Figure 5 

Figure 5 ---- Instrument to controller communication direction

 Instrument to controller communication direction

 Instrument to controller communication direction

 Instrument to controller communication direction    

 

 

For the instruments that use dual tone Patches (e.g. Roland MKS-80), display 
indicates request to select the tone layer first (“A

A

A

A ----B.

B.

B.

B.” or “U

U

U

U----L.

L.

L.

L.”) 

.  

The required tone layer has to be selected by 

 or 

 button 

.  

  

Summary of Contents for TPE-1

Page 1: ...or Editor Editor Editor Controller Controller Controller Controller Version 1 0 Version 1 0 Version 1 0 Version 1 0 Owner s Manual Owner s Manual Owner s Manual Owner s Manual 2018 CHD Elektroservis 2...

Page 2: ...________________________________ 12 4 10 HARDWARE WARM RESET ____________________________________________________________ 12 4 11 FACTORY RESET_________________________________________________________...

Page 3: ...ument to standard MIDI CCs These can be recorded in your DAW easily edited and played back i e any editings from instrument panel are transmitted in real time as MIDI CCs Macro programmer Macro progra...

Page 4: ...ller 1 3 1 3 1 3 1 3 OPERATIONAL SYSTEM OS STRUCTURE OPERATIONAL SYSTEM OS STRUCTURE OPERATIONAL SYSTEM OS STRUCTURE OPERATIONAL SYSTEM OS STRUCTURE SAVVY s operational system OS consists of three bas...

Page 5: ...neously accordingly to the fixed algorithms The tone is not affected in the middle position i e value 64 Macros Macros Macros Macros MIDI CCs assigned to macro functions that simplify control of more...

Page 6: ...TIAL SET UP UP UP UP 2 1 2 1 2 1 2 1 POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY The device is powered from external DC power supply unit5 5 5 5 The device has no power switch It starts immedi...

Page 7: ...in your computer and open the previously downloaded OS file 3 Connect the SAVVY with a computer8 8 8 8 as shown on the picture 4 Connect power supply while pressing and holding the button Display ind...

Page 8: ...pen the previously downloaded tone bank file 3 Connect the SAVVY with a computer12 12 12 12 as shown on picture 4 Set communication to direction by SLCT button It is indicated by green LED 5 Play the...

Page 9: ...4 2 4 2 4 2 4 2 COMMUNICATION DIRECTION COMMUNICATION DIRECTION COMMUNICATION DIRECTION COMMUNICATION DIRECTION SAVVY can only work in one direction only work in one direction only work in one direct...

Page 10: ...is active 4 4 4 4 4 4 4 4 EDIT TONE EDIT TONE EDIT TONE EDIT TONE Tone data individual tone parameters can be edited either from MIDI controller or instrument seechapter4 2 and Manual Supplements for...

Page 11: ...umber 4 7 4 7 4 7 4 7 SEND TONE SEND TONE SEND TONE SEND TONE The button transmits tone data from SAVVY s edit buffer either to instrument if direction is active or to controller PC17 17 17 17 if dire...

Page 12: ...reset is launched by pushing button When the process is launched the device stops operation and indicates rSt rSt rSt rSt message When finished the device returns to initialization sequence see chapte...

Page 13: ...pander MIDI Memory Expander To receive and save the single tone from the instrument Figure 6 part A 1 Set the communication direction to 2 Select a tone on the instrument the tone data is automaticall...

Page 14: ...xpander setup can be expanded with PC DAW With the following setting you can easily create user tone library from downloaded tone banks or to record any parameter editing as MIDI CCs for easier DAW wo...

Page 15: ...s much larger than the capacity of the Instrument s internal memory 5 4 5 4 5 4 5 4 EXAMPLE 4 EXAMPLE 4 EXAMPLE 4 EXAMPLE 4 COMBINED SET COMBINED SET COMBINED SET COMBINED SET UPs UPs UPs UPs Previous...

Page 16: ...gure 11 Advanced Combined Set Advanced Combined Set Advanced Combined Set Advanced Combined Set up up up up 5 5 5 5 5 5 5 5 EXAMPLE 5 EXAMPLE 5 EXAMPLE 5 EXAMPLE 5 USB MIDI CONTROLLERS USB MIDI CONTRO...

Page 17: ...CCs MIDI CCs MIDI CCs MIDI Control Changes CCs commands are accepted transmitted in dependence on selected communication direction see chapter 4 2 If direction is selected received CCs are translated...

Page 18: ...NDITIONS WARRANTY CONDITIONS WARRANTY CONDITIONS The equipment is provided with thirty thirty thirty thirty months warranty months warranty months warranty months warranty starting from the date of th...

Page 19: ...Mode 3 X X X X Mode 3 X X X X Not Altered Note Number Note Number Note Number Note Number X X X X X X X X 2 Velocity Velocity Velocity Velocity Note ON Note OFF X X X X X X X X X X X X X X X X 2 After...

Page 20: ...jected E 05 Inconvenient lower version of the SAVVY device than loaded operational system requires Load correct lower version of operational system Rejected E 11 Input MIDI Buffer Overflow Turn the de...

Page 21: ...useonly shielded interconnecting cables LITHIUM BATTERY WARNING LITHIUM BATTERY WARNING LITHIUM BATTERY WARNING LITHIUM BATTERY WARNING CAUTION CAUTION CAUTION CAUTION This product may contain a lithi...

Page 22: ...the written permission of CHD Elektroservis 22 22 22 22 DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Manufacturer s Name CHD Elektroservis M...

Page 23: ...1 BIOS ver 1 00 1 BIOS ver 1 00 1 BIOS ver 1 00 1 BIOS ver 1 00 Copyright 2018 CHD Elektroservis All rights reserved No part of this publication may be reproduced in any form without the written permi...

Page 24: ......

Reviews: