![Chauvin Arnoux ORITEL RW 521 User Manual Download Page 9](http://html1.mh-extra.com/html/chauvin-arnoux/oritel-rw-521/oritel-rw-521_user-manual_2594475009.webp)
9
4.
4.
4.
4.
4. GENERAL SPECIFICA
GENERAL SPECIFICA
GENERAL SPECIFICA
GENERAL SPECIFICA
GENERAL SPECIFICATIONS
TIONS
TIONS
TIONS
TIONS
n
Frequency range : 1.3 GHz to 2.7 GHz.
n
Incident power ranges :
- direct reading of all 6 galvanometer ranges
- full-scale value : + 15 dBm, + 20 dBm, + 25 dBm, + 30 dBm, + 35 dBm, + 40 dBm
(1)
n
Reflected power ranges:
- direct reading of all 6 galvanometer ranges
- full-scale value : + 10 dBm, + 15 dBm, + 20 dBm, + 25 dBm, + 30 dBm, + 35 dBm
n
Measurement accuracy : ± 6%
(2)
n
Impedance : 50
Ω
n
Insertion loss :
≤
0.1dB
n
SWR :
≤
1.15
n
Power supply : 2 x 1.5 V R6 / AA type batteries
n
Climatic conditions :
Operating temperature : 0°C to + 50°C
n
Dimensions (l x h x d) / Weight : 180 x 120 x 60 mm / 1.4 kg approx.
(1) This scale is calibrated and graduated up to + 41 dBm
(2) As a % of the full scale value, b20°C and +25°C, for power measured with a spectral purity
of
≥
40dB. Instrument in a vertical position.
5. MAINTENANCE
5. MAINTENANCE
5. MAINTENANCE
5. MAINTENANCE
5. MAINTENANCE
For maintenance
For maintenance
For maintenance
For maintenance
For maintenance,,,,, use onl
use onl
use onl
use onl
use only specified spare par
y specified spare par
y specified spare par
y specified spare par
y specified spare parts.
ts.
ts.
ts.
ts. The man
The man
The man
The man
The manufacturer will not be held responsib
ufacturer will not be held responsib
ufacturer will not be held responsib
ufacturer will not be held responsib
ufacturer will not be held responsible
le
le
le
le
fffffor an
or an
or an
or an
or any accident occuring f
y accident occuring f
y accident occuring f
y accident occuring f
y accident occuring follo
ollo
ollo
ollo
ollowing a repair done other than b
wing a repair done other than b
wing a repair done other than b
wing a repair done other than b
wing a repair done other than by its After Sales Ser
y its After Sales Ser
y its After Sales Ser
y its After Sales Ser
y its After Sales Service or appr
vice or appr
vice or appr
vice or appr
vice or appro
o
o
o
oved
ved
ved
ved
ved
repairer
repairer
repairer
repairer
repairers.
s.
s.
s.
s.
5.1
5.1
5.1
5.1
5.1
Replacing the batteries
Replacing the batteries
Replacing the batteries
Replacing the batteries
Replacing the batteries
Al
Al
Al
Al
Alwa
wa
wa
wa
ways disconnect the instrument fr
ys disconnect the instrument fr
ys disconnect the instrument fr
ys disconnect the instrument fr
ys disconnect the instrument from the installation bef
om the installation bef
om the installation bef
om the installation bef
om the installation before c
ore c
ore c
ore c
ore changing the batteries
hanging the batteries
hanging the batteries
hanging the batteries
hanging the batteries
- remove the cover at the bottom of the back by unscrewing the 2 quarter-turn screws,
- remove the used batteries and replace them with new 1.5 V R6 / AA type batteries,
- replace the cover before reconnecting the instrument.
5.2
5.2
5.2
5.2
5.2
Metr
Metr
Metr
Metr
Metrological verification
ological verification
ological verification
ological verification
ological verification
It is essential that all measuring instruments are regularl
It is essential that all measuring instruments are regularl
It is essential that all measuring instruments are regularl
It is essential that all measuring instruments are regularl
It is essential that all measuring instruments are regularly calibrated.
y calibrated.
y calibrated.
y calibrated.
y calibrated.
For checking and calibration of your instrument, please contact our accredited laboratories (list on request)
or the Chauvin Arnoux subsidiary or Agent in your country.
n
Repair
Repair
Repair
Repair
Repairs under or out of guarantee
s under or out of guarantee
s under or out of guarantee
s under or out of guarantee
s under or out of guarantee
please return the product to your distributor.
Summary of Contents for ORITEL RW 521
Page 11: ...11...