15
■
To get the resistance in
Ω
, multiply the reading on the
Ω
scale
(green) by the coefficient of the selected range: x 1 or x 100.
6 - RESISTANCES
Never test a resistance on a live circuit.
7 - CONTINUITY SOUND TEST
■
Connection and specifications: idem Resistances
■
Place the selector switch on the
x 1 function
■
Continuous audible beep emitted for a resistance R < 50
Ω
8 - GENERAL SPECIFICATIONS
8-1 Dimensions and weight
■
56 x 105 x 160 mm
■
500 g
8-2 Power supply
■
One battery 9 V (type 6F22 or 6LF22 alkaline)
■
Battery life:
- 10,000 measurements of 15 seconds with alkaline battery for
R > 50
Ω
- 4000 measurements of 5 seconds for R < 50
Ω
(with beep)
If the “Voltest” light comes on, presence of a voltage U > 15 V
AC/DC. Unplug the leads immediately and cut off the voltage
before making the resistance measurement.
■
Connect to the circuit or the component to test.
Ω
x1
(1)
x100
Measurement
extent
5
Ω
to
10 k
Ω
500
Ω
to 1 M
Ω
Internal
resistance
140
Ω
14 k
Ω
End of scale
current
10 mA
150 µA
Accuracy
(2)
10 %
Permitted
overload
440 V
(1) Common to the continuity
sound test
(2) In % at mid-scale.
Summary of Contents for C.A 5001
Page 42: ...42 12 ANNEXE APPENDIX ANHANG ALLEGATO ANEXO 3 1 2 5 4...
Page 43: ...43...