7. WARRANTY

Except as otherwise stated, our warranty is valid for 

24 months

 starting from the date on which the equipment was sold. Extract 

from our General Conditions of Sale provided on request.

The warranty does not apply in the following cases:

 

„

Inappropriate use of the equipment or use with incompatible equipment;

 

„

Modifications made to the equipment without the explicit permission of the manufacturer’s technical staff;

 

„

Work done on the device by a person not approved by the manufacturer;

 

„

Adaptation to a particular application not anticipated in the definition of the equipment or not indicated in the user’s manual;

 

„

Damage caused by shocks, falls, or floods.

Summary of Contents for C.A 1110

Page 1: ...Lux meter GB User s manual C A 1110...

Page 2: ...V with respect to ground Failure to ob serve the safety instructions may result in electric shock fire explosion and destruction of the instrument and of the installations The operator and or the resp...

Page 3: ...n 12 4 2 Get Data Logger Transfer software 12 4 3 USB link 12 4 4 Bluetooth link 13 4 5 Data Logger Transfer software 13 5 TECHNICAL CHARACTERISTICS 16 5 1 Reference conditions 16 5 2 Optical characte...

Page 4: ...g started guide one multilingual safety data sheet one test report one carrying case 1 2 ACCESSORIES Multi purpose attachment accessory Carrying bag USB Bluetooth adapter USB mains adapter with USB mi...

Page 5: ...to a metallic surface Battery compartment cover Press the tab of the battery compartment cover and lift it clear Withdraw the battery compartment cover Insert the new batteries paying attention to th...

Page 6: ...INSTRUMENT 2 1 C A 1110 Keypad with 5 keys On Off key Type B micro USB connector Backlit LCD display unit Cover protecting the sensor captive Illumination sensor Spiral wound cable used to remote the...

Page 7: ...Bluetooth link or a USB cable The Data Logger Transfer software can be installed on a PC and is used to configure the instruments and to recover the recorded measurements 2 3 FUNCTION KEYS Key Functi...

Page 8: ...ed and the instrument is in permanent mode This occurs when the instrument is recording in MAX AVG MIN mode in MAP mode or in HOLD the instrument is connected via the USB cord either to an external po...

Page 9: ...t mode Other sources this is the default light source Nothing is indicated on the display unit Place the sensor on the surface on which you wish to know the illumination Take care not to throw off the...

Page 10: ...ablish a map in conformity with good practice Place the sensor on the first measurement point and press the MEM key to record the value in memory The counter is incremented lx P MAP MAP lx P MIN AVG M...

Page 11: ...for repair Er 02 Error in internal memory Format it using Windows Er 03 Hardware malfunction detected The instrument must be sent in for repair Er 10 The instrument has not been adjusted or is not cor...

Page 12: ...ftware Then search on the name of your instrument Download the software then install it on your PC You must have administrator privileges on your PC to install the Data Logger Transfer software Minimu...

Page 13: ...WARE Once the instrument has been connected to the PC whether by USB or by Bluetooth open the Data Logger Transfer software For context sensitive information about the use of the Data Logger Transfer...

Page 14: ...sign a name to the recording session Then enter a starting date and time and an ending date and time or a duration The maximum duration of a recording session depends on the memory available Choose a...

Page 15: ...ou want to export and convert it into a word processing document docx or a spreadsheet xlsx in order to be able to use it in the form of reports or curves It is also possible to export the data to the...

Page 16: ...TS Specified measure ment range 0 1 to 200 000lx 0 01 to 18 580fc Resolution 0 1 to 999 9lx 1 000 to 9 999 klx 10 00 to 99 99 klx 100 0 to 200 0 klx 0 01 to 99 99fc 100 0 to 999 9fc 1 000 to 9 999kfc...

Page 17: ...A 1110 provides 3 measurement compensations Illuminant A default LED at 4000 K Fluorescent of type F11 The LED compensation is provided for measurements on LEDs at 4000 K The intrinsic uncertainty in...

Page 18: ...rechargeable batteries even when correctly charged will not reach the voltage of the alkaline batteries and the life indicated will be or The voltage range ensuring correct operation is from 3 to 4 5V...

Page 19: ...cm Mass 345 g approx Inrush protection IP 50 with the USB connector closed and the protecting cap on the sensor per IEC 60 529 Drop impact test 1 m per IEC 61010 1 5 9 COMPLIANCE WITH INTERNATIONAL S...

Page 20: ...ERIES The symbol indicates the remaining battery life When the symbol is empty all of the batteries must be replaced Disconnect everything connected to the instrument and switch it off Refer to 1 4 fo...

Page 21: ...C using the USB cord provided Copy the bin file to the instrument as if were a USB key When the copying is done press the MEM key and the instrument displays LOAD indicating that the software is being...

Page 22: ...following cases Inappropriate use of the equipment or use with incompatible equipment Modifications made to the equipment without the explicit permission of the manufacturer s technical staff Work do...

Page 23: ...andard NF C 42 710 fluorescent tubes with three narrow bands or F11 LEDs at 4000K 8 1 1 CURVE OF ILLUMINANT A 0 0 2 0 4 0 6 0 8 1 350 450 550 650 750 Standardized spectral distribution 0 0 2 0 4 0 6 0...

Page 24: ...nd corridors warehouses 100lx Dock and loading areas 150lx Changing rooms cafeteria and sanitary facilities 200lx Handling packaging and dispatching areas 300lx Conference and meeting rooms writing re...

Page 25: ...25...

Page 26: ...Fax 33 1 46 27 73 89 info chauvin arnoux com www chauvin arnoux com INTERNATIONAL Chauvin Arnoux Group T l 33 1 44 85 44 38 Fax 33 1 46 27 95 69 Our international contacts www chauvin arnoux com conta...

Reviews: