Chauvet TRIDENT User Manual Download Page 8

 
4. Operating Instructions 

Rev. 2 

Custom Program 

This fixture has individual control over each of the following functions via DIP switches: color, strobe, and 
motor rotation. These functions may be combined in any combination. Please see the instructions below 
for further explanation. 

 

1. 

Plug the fixture into power. 

2. 

Turn DIP switches [8] ~ [10] to the OFF position. 

3. 

DIP switches [1] ~ [3] control the color. These may be combined. 

4. 

DIP switches [4] ~ [6] control the strobe speed. Only 1 of these may be selected at a time. 
Turning them all to the OFF position allows the color to remain on constant. 

5. 

DIP switch [7] controls the motor rotation. Turning this to the ON position will cause the motor to 
rotate CW/CCW at a preset speed. This may not be altered. 

 
 

Do not connect a DMX controller to the daisy chain for this operation. 

 

 

DMX Channel Values 

 

C

HANNEL

 

V

ALUE

 

F

UNCTION

 

 

000 

 004 

005 

 028 

029 

 056 

057 

 084 

085 

 112 

113 

 140 

141 

 168 

169 

 197 

198 

 224 

225 

 255 

Color Selection (no dimming) 

Blackout 
Red 
Green 
Blue 
Green/Blue 
Red/Blue 
Red/Green 
Red/Green/Blue 
3-color chase 
7-color chase 

 

000 

 004 

005 

 255 

Strobe 

No function 
Strobe (slow 

 fast) 

 

000 

 127 

128 

 255 

Rotation 

Indexing 
Rotate (fast to slow) 

 

 

DIP Switch Values 

 

F

UNCTIONS

 

DIP

 SWITCHES

 

N

OTES 

&

 

D

ESCRIPTION

 

Red 

Combine these DIP switches to trigger simultaneously 

Green 

Blue 

Strobe (slow) 

Only 1 of these may be selected at a time 

Strobe (medium) 

Strobe (fast) 

Motor 

ON = bi-directional rotation 

Automatic 

Overrides DIP switches 1~6 

Sound-activated 

Overrides DIP switches 1~6 

DMX /Slave 

10 

DMX mode/Slave mode activation 

Summary of Contents for TRIDENT

Page 1: ...L 33351 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Page 2: ...N 7 MASTER SLAVE 7 STANDALONE OPERATION 7 Automatic 7 Sound Active 7 Custom Program 8 DMX CHANNEL VALUES 8 DIP SWITCH VALUES 8 5 APPENDIX 9 GENERAL MAINTENANCE 9 POWER LINKING 9 SETTING THE STARTING ADDRESS 9 GENERAL TROUBLESHOOTING 10 RETURNS 11 CLAIMS 11 TECHNICAL SPECIFICATIONS 12 CONTACT US 12 CHAUVET 2012 All Rights Reserved Information and specifications in this User Manual are subject to ch...

Page 3: ...te certain types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A val...

Page 4: ...Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Never connect the device to a dimmer pack Make sure the power cord is never crimped or ...

Page 5: ...oduction 5 Rev 2 Product Overview Safety attachment point Hanging bracket Fuse holder Power in Power out DMX in DMX out DIP switches Microphone Microphone sensitivity adjustment knob Back Panel A Back Panel B ...

Page 6: ...e The maximum quantity of fixtures that may be linked is 26 Mounting Orientation The Trident may be mounted in any safe position provided there is adequate room for ventilation Rigging Be sure that the structure can support the weight of the fixture Mount the product securely This may be done with a screw nut and bolt or a hanging clamp Be sure to also use a safety cable The hole in each bracket i...

Page 7: ...which will allow 1 fixture to act as the master and control all of the other slave fixtures You must set both the master and the slave s fixtures to the correct mode for this operation They must also be connected using DMX cables in a daisy chain fashion Master Settings 1 Using the DIP switches set the master fixture to one of the following modes custom automatic or sound activated Slave Settings ...

Page 8: ...r to rotate CW CCW at a preset speed This may not be altered Do not connect a DMX controller to the daisy chain for this operation DMX Channel Values CHANNEL VALUE FUNCTION 1 000 004 005 028 029 056 057 084 085 112 113 140 141 168 169 197 198 224 225 255 Color Selection no dimming Blackout Red Green Blue Green Blue Red Blue Red Green Red Green Blue 3 color chase 7 color chase 2 000 004 005 255 Str...

Page 9: ...y 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Power Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines t...

Page 10: ...ed DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier right aft...

Page 11: ...r double boxing are recommended CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the dam...

Page 12: ...le 155 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 3 ORDERING INFORMATION Trident TRIDENT WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us World Wide General Information CHAUVET 5200 NW 108th...