background image

7

 Lamp : Discharge lamp MSD 250W
 Color Temperature : 8000K
 Average Life : 2000 hours

1. Always switch off the main supply and never handle the lamp or luminaries when is

hot.

2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured

alcohol and wipe it with a lint free cloth before installation.

3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube

rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp any longer than its specified life.

5. Make sure the lamp is located in the center of the reflector for the best spot.

Diagram for Lamp changing

3.1 How to change the frequency 50Hz / 60Hz

1. Always switch off the main supply
, open the p

lastic base-cover. 

Find

the ballast on the 

housing-base.

2. Loose the screw of the red wire on
the ballast, and change the frequency.
3. Reinstall all.

 4. How To Set The Unit

 4.1 Control Panel

Display

To show the various menu and the selected functions.

LED

DMX

On

DMX input present

MASTER

On

master mode

SLAVE

On

slave mode

SOUND

Flashing

sound activation

Button

MENU

to select the programming functions

DOWN

to go backward in the selected functions

UP

to go forward in the selected functions

ENTER

to confirm the selected functions

Remote controller input

By connect to the 1/4” microphone jack to control the unit for Stand by, Strobe/Next and
Fast/Slow function.

Sensitivity

To adjust the microphone-receiving sensitivity.

Microphone

To receives audio signal for sound activation.

DMX input/output

For DMX512 link, use 3-pin XLR plug cable to link the unit together.

 5. How To Control The Unit

You can operate the unit in three ways:

 

1. By master/slave built-in preprogram function

 2. By easy controller
 3. By universal DMX controller

No need to turn the unit off when you change the DMX address, as new DMX address

setting will be effected at once. Every time you turn the unit on, it will show A660 on the
display and move all the motors to their ‘home’ position and you may hear some noises for
about 20 seconds. After that the unit will be ready to receive DMX signal or run the built in
programs.

 5.1 Master/Slave Built In Preprogrammed Function

By linking the units in master/slave connection, the first unit will control the other units to

give an automatic, sound activated, synchronized light show. This function is good when you

want an instant show. You have to set the first unit in master mode 

 and select

 (show 1) or 

 (show 2) mode. Its DMX input jack will have nothing plugged into

it, and Its master LED will be constantly on and sound LED will flash to the music. The other

units will have to set in slave mode 

 and select 

 (normal) or 

 (2 light

show) mode, Their DMX cables plugged into the DMX input jacks (daisy chain) and the slave
led lights will constantly on.

2-light show

In 

 (slave mode),

 

 

means the unit works normally and 

 

means 2-light

show. In order to create a great light show, you can set 

 

on the second unit to get

contrast movement to each other, even if you have two units only.

Summary of Contents for TRACKSCAN 250R

Page 1: ...in x 8 1in Weight 17 kg 37 4 lbs 13 5 kg 29 7 lbs User Information Please complete for your records Data Purchased Serial No Dealer Stamp Model TRACKSCAN DMX 606R TRACKSCAN 250R DMX 606R User Guide Please read these instructions carefully before use World wide Headquarters 3000 North 29 th Ct Hollywood Florida USA FL 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 www ChauvetLighting com ...

Page 2: ...512 Connection 6 Troubleshooting 7 Fixture Cleaning 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics ü Clean with soft clot...

Page 3: ...he same type l Make sure there is no flammable materials close to the unit while operating as it is fire hazard l Maximum ambient temperature is TA 40 Don t operate it at where the temperature is higher than this l Unit surface temperature may reach up to 85C Don t touch the housing bare hand during its operation and allow about 15 minutes to cool down before replacing bulb or serving as the unit ...

Page 4: ...dition F The lamp is cutting out intermittently 1 The lamp is not working well Check the main voltage either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan on the head 5 5 DMX512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels DMX 512 Termination reduces signal errors and to avoid signal Resistan...

Page 5: ...d DMX512 signal addressing and can be controlled by any universal DMX controller Channel 1 Shutter Channel 2 Gobos Channel 3 Gobo rotation Channel 4 Colors Channel 5 Pan motion Channel 6 Tilt motion Dimension 560mm x 250mm x 205 mm without bracket Weight 17 kg AC 120V 13 5 kg AC 230 250V Luminous intensity 2 1 Inserting Exchanging rotating gobos DANGER Install the gobos with the device switched of...

Page 6: ...se desired color and gobo It will change ten colors and then change one gobo 3 FAST SLOW When the LED is off it is in FAST mode The unit s movement Pan Tilt Gobo Color is sound activated If the LED on it is in SLOW mode Pan Tilt is sound activated but Gobo Color wheel are static controlled by Next button 5 3 Universal DMX Controller If you use a universal DMX controller to control the units you ha...

Page 7: ...nd by Strobe Next and Fast Slow function Sensitivity To adjust the microphone receiving sensitivity Microphone To receives audio signal for sound activation DMX input output For DMX512 link use 3 pin XLR plug cable to link the unit together 5 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By universal DMX control...

Page 8: ...s the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds To go back to the functions without any change press the MENU button The main functions are showing below DMX512 Address Setting Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change th...

Page 9: ...the normal or pan inversion mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Tilt Inversion Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP butt...

Reviews: