background image

6

Shaking

168~247

245

135

Slowest speed

128

Slowest speed

128

Stopped
121-134

Light green

121-127

Light green

116-127

Amber- Light green

114-120

112-127

Amber

108-113

Magenta-Amber

101-107

Amber

103-115

Magenta

94-100

96-111

Magenta

90-102

Shutter

88-167

Pink-Magenta

88-93

Pink

81-87

80-95

Pink

77-89

Orange-Pink

74-80

Orange

67-73

Orange

64-76

64-79

UV Purple-Orange

61-66

UV Purple

54-60

 UV Purple

52-63

Green-UV Purple

47-53

48-63

Green

41-46

Green

39-51

Yellow-Green

34-40

32-47

Yellow

27-33

Yellow

26-38

Blue-Yellow

21-26

16-31

Dimmer

08-87

00-15

120

10

Blue

13-25

Blue

14-20

White-Blue

07-13

Blackout

00-07

Stopped

00-09

White
00-12

White
00-06

 5.2 Easy Controller

The easy remote control is used only in master/slave mode. By connecting to the 1/4”

microphone jack of the first unit, you will find that the remote control on the first unit will
control all the other units for Stand by, Strobe/Next and Fast/Slow function.

1. 

STAND BY

 : To blackout all the unit.

2. 

STROBE/NEXT

 : Under FAST mode, the light will strobe in three different ways:

a.) Strobe in different gobos and colors.
b.) Synchronous strobe in white color.
c.) Two-light strobe in white color.
If  the  unit  in  slow  mode,  press  NEXT  button  to  choose  desired  color  and  gobo.  It  will
change ten colors and then change one gobo.

3. 

FAST/SLOW

 : When the LED is off, it is in FAST mode. The unit’s movement- Pan/Tilt &

Gobo/Color is sound activated. If the LED on, it is in SLOW mode, Pan/Tilt is sound
activated but Gobo/Color wheel are static, controlled by Next button.

 5.3 Universal DMX Controller

If you use a universal DMX controller to control the units, you have to set DMX address

from 1 to 512 channel so that the units can receive DMX signal.

Press the 

MENU

 button up to when the 

 

is showing on the display. Pressing

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512

address. Once the address has been selected, press and keep 

ENTER

 button pressed up to

when the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change press the

 MENU

 button again. 

Please refer to the following

diagram to address your DMX512 channel for the first 4 units.

 3. Lamp

 

Becau

se of its high internal pressure, there might be a risk that the Discharge lamp would
explode during operation. The lamp emits intense UV radiation which is harmful to the
eyes and skin. The high luminance of the arc can cause severe damage to the retina if
looked directly at the lamp.

In case of replacement of the lamp or maintenance, do not open the

 fixture within 15 minutes until the unit cools down after switching off.

Summary of Contents for TRACKSCAN 250R

Page 1: ...in x 8 1in Weight 17 kg 37 4 lbs 13 5 kg 29 7 lbs User Information Please complete for your records Data Purchased Serial No Dealer Stamp Model TRACKSCAN DMX 606R TRACKSCAN 250R DMX 606R User Guide Please read these instructions carefully before use World wide Headquarters 3000 North 29 th Ct Hollywood Florida USA FL 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 www ChauvetLighting com ...

Page 2: ...512 Connection 6 Troubleshooting 7 Fixture Cleaning 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics ü Clean with soft clot...

Page 3: ...he same type l Make sure there is no flammable materials close to the unit while operating as it is fire hazard l Maximum ambient temperature is TA 40 Don t operate it at where the temperature is higher than this l Unit surface temperature may reach up to 85C Don t touch the housing bare hand during its operation and allow about 15 minutes to cool down before replacing bulb or serving as the unit ...

Page 4: ...dition F The lamp is cutting out intermittently 1 The lamp is not working well Check the main voltage either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan on the head 5 5 DMX512 Connection The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels DMX 512 Termination reduces signal errors and to avoid signal Resistan...

Page 5: ...d DMX512 signal addressing and can be controlled by any universal DMX controller Channel 1 Shutter Channel 2 Gobos Channel 3 Gobo rotation Channel 4 Colors Channel 5 Pan motion Channel 6 Tilt motion Dimension 560mm x 250mm x 205 mm without bracket Weight 17 kg AC 120V 13 5 kg AC 230 250V Luminous intensity 2 1 Inserting Exchanging rotating gobos DANGER Install the gobos with the device switched of...

Page 6: ...se desired color and gobo It will change ten colors and then change one gobo 3 FAST SLOW When the LED is off it is in FAST mode The unit s movement Pan Tilt Gobo Color is sound activated If the LED on it is in SLOW mode Pan Tilt is sound activated but Gobo Color wheel are static controlled by Next button 5 3 Universal DMX Controller If you use a universal DMX controller to control the units you ha...

Page 7: ...nd by Strobe Next and Fast Slow function Sensitivity To adjust the microphone receiving sensitivity Microphone To receives audio signal for sound activation DMX input output For DMX512 link use 3 pin XLR plug cable to link the unit together 5 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By universal DMX control...

Page 8: ...s the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds To go back to the functions without any change press the MENU button The main functions are showing below DMX512 Address Setting Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change th...

Page 9: ...the normal or pan inversion mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Tilt Inversion Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP butt...