Introduction
Congratulations on the purchase of your new Chauvet dimmer pack. We are confident that you will
enjoy many trouble free hours with this unit. To assist with the use and care of this unit, we have pre-
pared this short guide.
Operation
This dimmer pack has been designed to function on Single phase or Three phase power and has been
fitted with a suitable hard wire terminals. The TFX-6D will accept DMX signals or analog signals (0-10V)
from a dimmer controller.
1. 20A
breaker------
This is a six channel dimmer each channel has an independent 20 amp circuit breaker.
2. Preheat adjuster maximum is 50%----Lengthens dimming capability.
3. Power indicator----Indicates unit has power.
4. Channel output indicator----Indicates that light should be on.
5. DMX indicator-----Indicates that DMX is being received.
6. Power switch-----Turn unit on and off.
7. Channel dimmer control-----Allows manual adjustment of channel. It will not override a channel
that has been turned on via DMX.
8. DMX address dip switches-----This is where you set the DMX address of the dimmer pack based on
controller you are using.
9. Load indicator-----Lights will stay on when there is no load (i.e. no light connected).
10. DMX out----- (drawing A)
11. DMX input-----(drawing A)
12. Analog output (0-10v)-----Used for daisy chaining more the one analog units on the same controller.
(drawing A)
13. Analog input (0-10v)-----(drawing A)
14. Power connection box-----See drawing B