background image

 

 

 

 

SlimPANEL™ TRI 24 IP User Manual (Rev. 4) 

Page 9 of 17 

4.

 

O

PERATION

 

 

 

Control Panel 

Operation 

To access the control panel functions,  use the four buttons located underneath the 

display. Please refer to the Product Overview to see the button locations on the control 

panel.  

 

 

 

Button 

Function

 

<MENU> 

Press to find an operation mode or to back out of the current menu 

option

 

<UP> 

Press to scroll up the list of options or to find a higher value

 

<DOWN> 

Press to scroll down the list of options or to find a lower value

 

<ENTER> 

Press to activate a menu option or a selected value

 

 

 

Menu Map 

Mode 

Programming Steps 

Description 

DMX Address 

Addr 

d__1-d512 

Selects DMX starting address 

DMX 

Personalities 

PRES 

3CH 

Selects DMX personality 

4CH 
5CH 
9CH 

Dimmer 

DIM 

OFF 

Change dimmer speed 

DIM1 
DIM2 
DIM3 

Static Color 

C-- 

C1 

Red 

C2 

Green 

C3 

Blue 

C4 

Cyan 

C5 

Magenta 

C6 

Yellow 

C7 

White 

Touch Control 

Panel Lock 

PASS 

ON 

Locks touch control panel 
Password is 

UP,DOWN,UP,DOWN,ENTER 

OFF 

Custom Color 

Mixing 

U-- 

r-- 

Red 

g-- 

Green 

b-- 

Blue 

S-- 

Strobe rate 

Auto Programs 

P-- 

P1 

S__1-

S100 

Auto program selection and speed 

selection 

P2 
P3 
P4 
P5 

 

 

 

 

Summary of Contents for SlimPANEL TRI 24 IP

Page 1: ...User Manual ...

Page 2: ... 8 Orientation 8 Rigging 8 4 Operation 9 Control Panel Operation 9 Menu Map 9 Configuration DMX 10 DMX Personalities and Starting Address 10 DMX Channel Assignments and Values 11 3 CH 11 4 CH 11 5 CH 11 DMX Channel Assignments and Values cont 12 9 CH 12 Configuration Standalone 13 Automatic Mode 13 Static Color Mode 13 Custom Static Color Mode 13 Dimmer Adjustment 13 Touch Control Panel Lock 14 Ma...

Page 3: ...ch only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Failure to comply with this information may cause the product to not work damage it or cause harm ...

Page 4: ...using when operating because it may be very hot Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor or outdoor use IP65 Do not submerge the product Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure th...

Page 5: ...SlimPANEL TRI 24 IP User Manual Rev 4 Page 5 of 17 2 INTRODUCTION Product Overview Touch Display Power Out DMX Out Power In DMX In Mounting Bracket ...

Page 6: ...Page 6 of 17 SlimPANEL TRI 24 IP User Manual Rev 4 Product Dimensions ...

Page 7: ...iate electrical ground to avoid the risk of electrocution or fire Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Power Linking The product provides a power linking option via the pigtails located on the back of the unit You can daisy chain up to 6 units on 120 VAC or up to 12 units on 230 VAC If yo...

Page 8: ... which you are mounting the product can support the product s weight Please see the Technical Specifications section of this manual for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capaci...

Page 9: ...scroll down the list of options or to find a lower value ENTER Press to activate a menu option or a selected value Menu Map Mode Programming Steps Description DMX Address Addr d__1 d512 Selects DMX starting address DMX Personalities PRES 3CH Selects DMX personality 4CH 5CH 9CH Dimmer DIM OFF Change dimmer speed DIM1 DIM2 DIM3 Static Color C C1 Red C2 Green C3 Blue C4 Cyan C5 Magenta C6 Yellow C7 W...

Page 10: ... DMX mode which defines the highest configurable address to 504 When selecting a starting DMX address always consider the number of DMX channels the selected DMX mode uses If you choose a starting address that is too high you could restrict the access to some of the product s channels If you are not familiar with the DMX protocol download the DMX Primer at www chauvetlighting com To select the DMX...

Page 11: ...100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 CH Channel Function Value Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 CH Channel Function Value Setting 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 Dimmer 000 255 0 100 5 Strobe 000 010 No function 011 255 Slow to fast ...

Page 12: ...21 225 White 5 5600K 226 230 White 6 5900K 231 235 White 7 6500K 236 240 White 8 7200K 241 245 White 9 8000K 246 250 White 10 8500K 251 255 White 11 10000K 6 Strobe 000 009 No function 010 255 0 100 slow to fast 7 Auto Programs 000 051 No function 052 101 Auto Program 1 102 152 Auto Program 2 153 203 Auto Program 3 204 254 Auto Program 4 255 Auto Program 5 8 Auto Program Speed 000 255 Slow to fast...

Page 13: ...or Mode follow the instructions below 1 Press MENU repeatedly until C shows on the display 2 Press ENTER 3 Use UP or DOWN to choose a color C1 C7 4 Press ENTER Custom Static Color Mode To enable the Custom Static Color Mode follow the instructions below 1 Press MENU repeatedly until U shows on the display 2 Press ENTER to choose between colors r g b 3 Press UP or DOWN to choose the intensity of th...

Page 14: ...ntroller The master unit will be set to operate in a standalone mode while the slave units will be set to operate in Slave Mode Once set and connected the slave units will operate in unison with the master unit Configure the units as indicated below Slave units 1 Press MENU repeatedly until Addr shows on the display 2 Press ENTER to accept 3 Set the DMX address to 001 4 Connect the DMX input of th...

Page 15: ...plug the product from power Wait until the product is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents Clean all external optics and glass transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue Softly drag any ...

Page 16: ... A 6 units 8 A 12 units Fuse F 2 A 250 V F 2 A 250 V Power I O U S Worldwide UK Europe Power input connector Proprietary Proprietary Power output connector Proprietary Proprietary Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 3 W 50 000 hours Color Quantity Current Tri color 24 350 mA x3 Photo Optic Parameter Illuminance 2 m 5 850 lux Beam angle 20º Field angle 34 Ther...

Page 17: ... the RMA number CHAUVET will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box Before sending the product clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number The RMA number A brief description of the problem Be sure to pack th...

Reviews: