Operation
Page 9 of 44
5.
O
PERATION
This product is not designed for continual use. Make sure there are regular
breaks during operation to maximize the life of your laser.
Always disconnect the Scorpion™ Scan 3D EU from power when not in use.
A Laser Safety Scanner Board is built-in. Laser light will automatically be turned
off when the scanned angle is less than 2°.
Control Panel
Operation
To access the control panel functions, use the four buttons located underneath the display. When the
product is on, the LED monitor on the rear panel will show the current operating mode (standalone or
DMX). The product will retain the last saved settings when powered off.
Button
Function
<FUNC>
Selects an operation mode or to backs out of the current menu option
<UP>
Scrolls up the list of options or selects a higher value
<DOWN>
Scrolls down the list of options or selects a lower value
<ENTER>
Activates a menu option or a selected value
Menu Map
Mode or Starting Value
Program or Channel Range
Options
Description
Standalone
Speed
Pre-programmed effects that cannot be customized
Aut
S 0~S 9
Automatic (Random)
A3d
S 0~S 9
Effect 1 (3D)
Aub
S 0~S 9
Effect 2 (Beams)
AUL
S 0~S 9
Effect 3 (Cirrus)
AUN
S 0~S 9
Effect 4 (Storm)
AUO
S 0~S 9
Effect 5 (Infinity)
Sound-Active
Sensitivity
The product responds to the beat of the music
SOU
S 0~S 9
Sound (Random)
S3D
S 0~S 9
Effect 1 (3D)
Sob
S 0~S 9
Effect 2 (Beams)
SoL
S 0~S 9
Effect 3 (Cirrus)
Son
S 0~S 9
Effect 4 (Storm)
Soo
S 0~S 9
Effect 5 (Infinity)
DMX
000~492
DMX mode
SLAV
Master/slave mode
S =
˧
Image orientation
Configuration
(DMX)
Set the product in DMX mode to control with a DMX controller.
1.
Connect the product to a suitable power outlet.
2.
Turn the product on.
3.
Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the
product.
Starting Address
The Scorpion™ Scan 3D EU uses up to 19 DMX channels in its DMX mode, which defines the highest
configurable address to 474. If you are unfamiliar DMX, download the DMX Primer from
www.chauvetlighting.com
.
To select the starting address, do the following:
1.
Press
<FUNC>
three times.
2.
Press
<ENTER>
.
3.
Use
<UP>
or
<DOWN>
to select the starting address.
4.
Press
<ENTER>
.