![Chauvet PiX PAR 24 Quick Reference Manual Download Page 5](http://html.mh-extra.com/html/chauvet/pix-par-24/pix-par-24_quick-reference-manual_2593131005.webp)
EN
PiX™ PAR 24 QRG
Page 5 of 64
DMX Linking
The PiX™ PAR 24 can work with a DMX controller when linked by DMX
serial connections. Instructions for connecting and configuring this product
for DMX operation are in the User Manual. If you are not familiar with
DMX, download the DMX Primer from
www.chauvetlighting.com
.
Starting Address
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is
441
.
Master/Slave
Connection
The PiX™ PAR 24 uses the DMX data connection for its Master/Slave
mode. Instructions for connecting and configuring this product for
Master/Slave operation are in the User Manual.
DMX Values
3-CH
Channel Function
Value
Percent/Setting
1
Red
000
ó
255 0~100%
2
Green
000
ó
255 0~100%
3
Blue
000
ó
255 0~100%
9-CH
Channel Function
Value
Percent/Setting
1
Dimmer
000
ó
255 0~100%
2
Red
000
ó
255 0~100%
3
Green
000
ó
255 0~100%
4
Blue
000
ó
255 0~100%
5
Color Macros
000
ó
010 No function
011
ó
200 Color Macros
201
ó
205 White 1: 3200K
206
ó
210 White 2: 3400K
211
ó
215 White 3: 4200K
216
ó
220 White 4: 4900K
221
ó
225 White 5: 5600K
226
ó
230 White 6: 5900K
231
ó
235 White 7: 6500K
236
ó
240 White 8: 7200K
241
ó
245 White 9: 8000K
246
ó
250 White 10: 8500K
251
ó
255 White 11: 10000K
6
Strobe
000
ó
009 No function
010
ó
255 0~30 Hz