Chauvet Motion Facade LED User Manual Download Page 8

 
 
 
 

Page 8 of 13 

MotionFaçade™ LED User Manual (Rev. 6) 

4.

 

O

PERATION

 

 

 

Control Panel 

Operation 

To  access the control panel functions, use the four buttons located underneath the 
display. Please refer to the Product Overview (page 5) to see the buttons location on the 
control panel.  

 

 

 

Button 

Function

 

<MENU> 

Press to find an operation mode or to back out of the current menu 
option

 

<ENTER> 

Press to activate a menu option or a selected value

 

<UP> 

Press to scroll up the list of options or to find a higher value

 

<DOWN> 

Press to scroll down the list of options or to find a lower value

 

 

Menu Map 

Mode 

Programming Steps 

Description 

Version 

Software Version 

Shows the software version number 

Automatic 

NO 

Disables unit’s auto mode function 

YES 

Enables unit’s auto mode function 

Sound 

NO 

Disables unit’s sound mode function 

YES 

Enables unit’s sound mode function 

DMX Mode 

NO 

Disables unit’s DMX512 mode function 

YES 

1~512 

Enables unit’s DMX512 mode and sets 
starting address 

Speed 

1~9 

Selects how fast the auto mode program 
runs 

Program 

1~30 

NO 

Disables numbered program running in 
sequence in auto or sound mode 

YES 

Enables numbered program running in 
sequence in auto or sound mode 

 

Configuration 

(DMX) 

Set this product in DMX mode to control with a DMX controller.  

1.  Connect the product to a suitable power outlet. 

2.  Turn the product on. 

3.  Connect a DMX cable from the DMX output of the DMX controller to the DMX input 

socket of the product. 

 

 

Starting Address 

When selecting a starting DMX address, always consider the number of DMX channels 
the selected DMX mode  uses. If you  choose a  starting address that is too high, you 
could restrict the access to some of the product’s channels. 

The  MotionFaçade™ LED  uses up to 8  DMX channels in its  8-channel DMX mode, 
which defines the highest configurable address to 

505

.  

If you are not familiar with the DMX protocol, download the DMX Primer from 

www.chauvetlighting.com

To select the starting address, do the following: 

1.  Press 

<MENU>

 repeatedly until 

Dmx512

 shows on the display. 

2.  Press 

<ENTER>

3.  Press 

<UP>

 to select 

Yes

 in the menu. 

4.  Press 

<ENTER>. Address

 should appear on the screen. 

5.  Use 

<UP>

 or 

<DOWN>

 to select the starting address. 

6.  Press 

<ENTER>

 

 

Summary of Contents for Motion Facade LED

Page 1: ...User Manual...

Page 2: ...oduction 5 Product Overview 5 Product Dimensions 5 3 Setup 6 AC Power 6 Fuse Replacement 6 Mounting 7 Orientation 7 Rigging 7 4 Operation 8 Control Panel Operation 8 Menu Map 8 Configuration DMX 8 Sta...

Page 3: ...12 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed o...

Page 4: ...t the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the product This product is for indoor use only IP20 To prevent risk of fi...

Page 5: ...onFa ade LED User Manual Rev 6 Page 5 of 13 2 INTRODUCTION Product Overview Product Dimensions Front Panel Button Menu LED Display Top Panel Curtain Input Power In Fuse holder On Off Switch DMX Out DM...

Page 6: ...the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement...

Page 7: ...to access the unit for maintenance and programming purposes Make sure that the structure onto which you are mounting this product can support its weight Please see the Technical Specifications sectio...

Page 8: ...the auto mode program runs Program 1 30 NO Disables numbered program running in sequence in auto or sound mode YES Enables numbered program running in sequence in auto or sound mode Configuration DMX...

Page 9: ...e may transmit DMX signals that could interfere with the DMX signals from the controller Sound Active Mode To enable the Sound Active mode do the following 1 Press MENU repeatedly until Sound shows on...

Page 10: ...ack 096 111 Multi Color Freeway 112 127 Color Wave L R 128 143 Color Wave R L 144 159 Color Bar Chase L R 160 175 Color Bar Chase R L 176 191 Windmill 192 207 Fan 208 223 Whirlpool 224 239 Falling Sno...

Page 11: ...LED controller not powered Check power to the MotionFa ade LED controller Faulty DMX cable Repair or replace faulty cable Breaker Fuse keeps blowing Excessive circuit load Check total load placed on...

Page 12: ...t Power Power Supply Type Range Voltage Selection Switching internal 100 240 V 50 60 Hz Auto ranging Parameter 120 V 60 Hz 230 V 50 Hz Consumption 21 W 23 W Operating 0 2 A 0 1 A Fuse F 2 A 250 V F 2...

Page 13: ...he U S United Kingdom or Ireland contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our website for contact details Returns Call the corre...

Reviews: