background image

 

 

 

 

Before You Begin 

Important Safety Information 

This product is designed for professional use. It is not intended for use in a household environment. 

This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet 

radiation, lamp explosion, and injury from falls. 

Read this manual 

before installing or powering the 

fixture, follow the safety precautions listed below and observe all warnings in this manual and on the 

fixture. If you have any questions about how to operate the fixture safely, please contact CHAUVET. 

 

P r o t e c t i o n   a g a i n s t   E l e c t r i c   S h o c k  

 

Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure 
to replace with same lamp source. 

 

All Class I fixtures must be connected to circuits with a suitable Earth Ground.  

 

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no 
flammable materials close to the unit while operating. 

 

Do not operate the fixture if covers are open or if any internal component is missing or damaged: 
an unshielded discharge lamp emits dangerous UV radiation that can cause burns and eye 
damage. 

 

Make sure power cord is never crimped or damaged.  

 

Never disconnect power cord by pulling or tugging on the cord. 

P r o t e c t i o n   a g a i n s t   F i r e   &   B u r n s  

 

This product is designed to be used with very specific lamp(s). Use of any other type of lamp not 
stated in this manual may create a fire hazard due to possible risk of lamp explosion. Using the 
wrong type of lamp in this product VOIDS the warranty. 

 

Always make sure that you are connecting to the proper voltage and that the line voltage you are 
connecting to is not higher than that stated on decal or rear panel of the fixture. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 
surfaces. Be sure that no ventilation slots are blocked. 

 

Maintain a minimum distance of 1 meter (3.28 feet) from combustible materials. 

 

Allow this product to cool for a minimum of 15 minutes before opening, handling or removing the 
lamp in this product. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate fixture at temperatures higher than 

this.  

P r o t e c t i o n   a g a i n s t   e x p o s u r e   t o   ( U V )   U l t r a vi o l e t   R a d i a t i o n  

 

Avoid direct eye exposure to lamp while it is on.  

 

Do not operate the fixture if covers are open or if any internal component is missing or damaged. 

P r o t e c t i o n   a g a i n s t   I n j u r y   t o   p e r s o n s  

 

Secure fixture to fastening device using a safety chain.  

 

A hot lamp is an explosion hazard. Do not open fixture for a minimum of 15 minutes after 
switching off. Wear eye and hand protection when re-lamping.  

 

Fixture surface may reach temperatures of up to 160° C (320° F). Handle fixture after it cools. 

 

In the event of serious operating problem, stop using the unit immediately. Never try to repair the 
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. 
Please contact the nearest authorized technical assistance center. Always use the same type 
spare parts. 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET.

ST-750 User Manual   

2007-03-20

/

15:10

 

Summary of Contents for Mega Strobe III

Page 1: ...Mega Strobe III ST 750 USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2007 03 20 15 10 ...

Page 2: ... OPERATING MODES 8 Stand Alone 8 Unison Strobe with optional strobe controller 8 5 APPENDIX 9 RETURNS PROCEDURE 9 CLAIMS 9 MAINTENANCE 9 TECHNICAL SPECIFICATIONS 10 TECHNICAL SUPPORT 10 CHAUVET 2006 All Rights Reserved Information and specifications in this User Manual are subject to change without notice CHAUVET assumes no responsibility or liability for any errors or inaccuracies that may appear...

Page 3: ...turned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x Mega Strobe III CH 750B lamp installed Warranty Card Users Manual Contact Us World Wide General Information Chauvet Lighting 3000 No...

Page 4: ...roduct VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Maintain a minimum distance of 1 meter 3 28 ...

Page 5: ...lash life Variable dimmer control knob Linkable via mono cable EST 10MONO Chase Sound activation via optional CH 751 SC 1000M DMX via optional DMX 752 converter Bulb CH 750B Product Overview SPEED DIM Safety Glass Variable dimming Hanging Yoke Speed Rotary knob ST 750 User Manual 5 2007 03 20 15 10 ...

Page 6: ...utral N Silver YELLOW GREEN Earth EG Ground Green Mounting Orientation This fixture can be mounted on a truss using a clamp in any position or against a flat surface using the brackets provided Rigging The fixture includes a mounting yoke to which 1 rigging clamp can be bolted You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture You can order C...

Page 7: ... from PCB Lamp is removed and replaced through the front of the fixture You must first remove the glass cover Attempt to remove the lamp after you have released all wire leads from the PCB Push back on both spring terminal ends inside the lamp reflector to release the linear lamp from the grip of both spring terminals and pull lamp outwards as you apply the pressure Repeat procedure to replace and...

Page 8: ...a SC 1000M controller The strobe speed and strobe intensity can all be adjusted and they are located on the bottom of the fixture SPEED DIM Unison Strobe with optional strobe controller The Unison strobe mode will allow you to link additional units in a daisy chain fashion Simply connect the first fixture to the strobe controller and connect each fixture in a daisy chain fashion using a MONO phone...

Page 9: ...ontributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure to power off fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust c...

Page 10: ...USE Main 20mm Glass 20A Fast Blow CONTROL PROGRAMMING Remote Controller Input MONO phone plug Output MONO phone plug ORDERING INFORMATION Mega Strobe III ST 750 Replacement bulb CH 750B 1 channel strobe controller CH 751 4 channel strobe controller SC 1000MONO Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone 954 929 111...