Optics

 

 

The Legend 1200E Spot has one  color wheel with seven colors and two gobo wheels 
that support six rotating, slot-n-lock gobos each. The colors in the color wheel are not 
replaceable, but the gobos are. 

   

 

Color Wheel 

 

The diagram below shows the  color  wheel and the names of each of the seven color 
filters on it.  

 

 

 

   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Control Panel 

Location 2 

Location 1 

Summary of Contents for Legend 1200E Wash

Page 1: ...User Manual ...

Page 2: ...r 210 x 297 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the Legend 1200E Spot should read the guide that shipped with it as well as this manual in their entirety before installing operating or maintaining this product Disclaimer CHAUVET believes that the information contained in this m...

Page 3: ...ower 7 AC Plug 7 Fuse Replacement 7 DMX Linking 7 DMX Modes 7 Mounting 8 Orientation 8 Rigging 8 Bracket Installation 9 Optics 9 Color Wheel 9 Gobo Wheels 10 Replacing Gobos 11 Lamp Replacement 12 Increasing the Lamp s Life 12 4 Operation 13 Control Panel Description 13 Home Screen 13 Control Options 13 Menu Map 14 Programming 15 Navigation Control 15 DMX Operation 15 Fixture Settings 15 Lamp Sett...

Page 4: ...end 1200E Spot User Manual Rev 03c 5 Technical Information 27 General Maintenance 27 Dust Screen Cleaning 27 Error Messages 28 Troubleshooting Guide 29 Returns Procedure 30 Claims 30 Contact Us 30 Technical Specifications 31 ...

Page 5: ...in the text 50 60 A set of mutually exclusive values in the text 10 A DIP switch to be configured Claims A new term or a section or chapter in this document COLORado UM The name of another publication or manual SET A button on the fixture s control panel Settings A fixture function or a menu option MENU Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu ...

Page 6: ...uct s housing when operating because it may be very hot Mounting and Rigging This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture Make sure there are no flammable materials close to this product while operating When hanging this product always secure it to a fastening device using a safety chain cable not provided Do not carry this fix...

Page 7: ...n Gobo wheel 2 Indexed rotating gobo wheel with gobo shake Six glass slot n lock gobos open one multicolor five B W Gobo wheel spin at variable speeds 16 bit gobo rotation Variable frost Variable CTC filter 3 200 6 000 K CMY color mixing system with vector speed adjustments 3 facet 5 facet 3D and infinite prism with macros Variable shutter Variable iris Variable focus Variable 16 bit dimming 0 100...

Page 8: ...Magenta 11 Magenta 11 Yellow 12 Yellow 12 3 200 K CTO Filter 13 3 200 K CTO 13 Gobo 1 14 CMY CTO Filter Speed 14 Gobo 1 rotation 15 Gobo 1 15 Gobo 2 16 Gobo 1 rotation 16 Gobo 2 rotation 17 Gobo 1 rotation fine 17 Focus 18 Gobo 2 18 Zoom 19 Gobo 2 rotation 19 Effect prism 20 Gobo 2 rotation fine 20 Effect prism rotation 21 Focus 21 Iris 22 Zoom 22 Frost 23 Effect prism 23 Function 24 Effect prism ...

Page 9: ...iew Power input ENTER button Jog Wheel POWER button Fuse holder Main MENU button Fuse holder Lamp Liquid Crystal Display DMX in 3 pin DMX out 3 pin DMX in 5 pin DMX out 5 pin DMX LED indicator Power LED indicator Tilt lock Carrying handle 1 of 2 Pan lock Control panel ...

Page 10: ...Introduction 6 Legend 1200E Spot User Manual Rev 03c Product Dimensions ...

Page 11: ...the fixture Use the table below to wire a plug for the power cord Connection Wire US Wire Europe Screw Color AC Live Black Brown Yellow or Brass AC Neutral White Blue Silver AC Ground Green Yellow Green Yellow Green Make sure to disconnect the fixture s power cord before replacing a blown fuse and always replace it with a fuse of the same type and rating Fuse Replacement 1 With a Phillips 2 screwd...

Page 12: ...ng the general guidelines below when mounting the Legend 1200E Spot When selecting an installation location consider ease of access to the fixture for operation programming adjustments and routine maintenance Never mount the fixture in places where rain high humidity extreme temperature changes or restricted ventilation may affect it If hanging this fixture make sure that the location where you ar...

Page 13: ...ion to access the control panel and the fuses Bracket Mounting Diagram Optics The Legend 1200E Spot has one color wheel with seven colors and two gobo wheels that support six rotating slot n lock gobos each The colors in the color wheel are not replaceable but the gobos are Color Wheel The diagram below shows the color wheel and the names of each of the seven color filters on it Control Panel Loca...

Page 14: ...egend 1200E Spot User Manual Rev 03c Gobo Wheels The diagram below shows both gobo wheels and the number assigned to each gobo on each wheel Rotating Gobo Wheel 1 Rotating Gobo Wheel 2 1 2 3 4 5 6 7 8 9 10 11 12 ...

Page 15: ...outlet 2 Open the head cover by loosening the four fastening screws at the sides of the top cover 3 Separate the gobo plate away from the gobo wheel by pushing it toward the front of the moving head Be careful not to push the gobo out of the gobo plate 4 Once released from its slot extract the gobo plate by pulling it outward 5 On a flat surface remove the expansion ring that holds the gobo in pla...

Page 16: ...te the ceramic base of the lamp 90º counterclockwise 6 Pull the lamp out by holding it from its base only 7 Insert the new lamp and turn it 90º clockwise 8 Reverse steps 3 and 4 9 Use the adjustment screws marked B in the diagram to position the lamp in the center of the reflector to obtain the best output Lamp Replacement Diagram FastFit Socket Positions Increasing the Lamp s Life NEVER turn the ...

Page 17: ... completing the power up tests the LCD will show the DMX address the DMX mode and the fixture s temperature along with the warning sign if the tests have detected an error When the warning sign shows press ENTER to read the corresponding error message see Error Messages in the Technical Information chapter Press ENTER while looking at an error messages to clear it Control Options You can set the L...

Page 18: ...cus Lamp Settings On Off On Off N A State Power On Off Via DMX No Yes On if DMX On Off if DMX Off Cooling Mode High Auto Ignition Delay 0 255 Low Power Delay Display Settings Display Inverse No Yes N A Back Light Auto Off Back Light Intensity 1 10 Temperature Unit C F Fixture Test Auto Test N A N A Manual Test 000 255 Fixture Information Fixture use time N A N A Lamp On Time Exit Reset Time Firmwa...

Page 19: ... fixture s DMX configuration To access this section do the following 1 Press MENU 2 Select DMX Functions 3 Select the corresponding function as indicated below 4 Press MENU to exit once you are done with this section DMX Address To select the starting DMX address do the following 1 Select DMX Address 2 Select a DMX address 001 512 3 Press ENTER DMX Modes To select the DMX mode whether Basic 23 cha...

Page 20: ...he parameters that affect the fixture s lamp and its operation To access this section do the following 1 Press MENU 2 Select Lamp Settings 3 Select the corresponding function as indicated below 4 Press MENU to exit once you are done with this section Lamp On Off This option allows turning the lamp off and back on without having to power cycle the fixture 1 Select On Off 2 Select Yes or No 3 Press ...

Page 21: ...ds 000 255 4 Press ENTER Display Settings The options in the Display Settings section control the operation of the fixture s LCD To access this section do the following 1 Press MENU 2 Select Display Settings 3 Select the corresponding function as indicated below 4 Press MENU to exit once you are done with this section Display Reversal This option reverses the LCD orientation 180º to read it uprigh...

Page 22: ...tion control the fixture usage timers and show the firmware version To access this section do the following 1 Press MENU 2 Select Fixture Information 3 Select the corresponding function as indicated below 4 Press MENU to exit once you are done with this section Fixture Operation Timer This option shows the time the fixture has been in operation 1 Select Fixture use time 2 Press ENTER The fixture w...

Page 23: ...etting 2 Press ENTER The zoom will move to its home position All This option resets all the motors to their corresponding home positions 1 Select All 2 Select Yes reset or No exit without resetting 2 Press ENTER All motors will move to their corresponding home positions Special Functions The Special Functions section comprises the maintenance timer options and the factory default option To access ...

Page 24: ...o exit once you are done with offset adjustments Pan Motor 1 Select Pan and press ENTER a pop up window will open a Select the new value 128 127 b Accept the new value Tilt Motor 1 Select Tilt and press ENTER a pop up window will open a Select the new value 128 127 b Accept the new value Shutter Motor 1 Select Shutter and press ENTER a pop up window will open a Select the new value 0 255 b Accept ...

Page 25: ...w value Iris Motor 1 Select Iris and press ENTER a Select the new value 0 255 b Accept the new value Prism Motor 1 Select Prism and press ENTER a Select the new value 0 255 b Accept the new value R Prism Motor 1 Select R Prism and press ENTER a Select the new value 128 127 b Accept the new value Frost Motor 1 Select Frost and press ENTER a Select the new value 0 255 b Accept the new value Focus Mo...

Page 26: ...t Colors CCW rotation fast slow Stop CW rotation slow fast 9 Cyan 000 255 0 100 10 Magenta 000 255 0 100 11 Yellow 000 255 0 100 12 3200 K Filter 000 255 0 100 13 Gobo 1 000 009 010 019 020 028 029 038 039 047 048 057 058 067 068 077 078 087 088 097 098 107 108 117 118 127 128 189 190 193 194 255 Open white Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 1 shake Gobo 2 shake Gobo 3 shake Gobo 4 sha...

Page 27: ... slow fast 21 Iris 000 255 100 0 22 Frost 000 179 180 201 202 223 224 245 246 255 0 100 Open closed fast slow Closed open fast slow Frost Frost effect 23 Function 000 009 010 019 020 029 030 039 040 049 050 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 219 220 229 230 239 240 255 No function Auto focus enable Auto focus disa...

Page 28: ...rotation fast slow Stop CW rotation slow fast 10 Cyan 000 255 0 100 11 Magenta 000 255 0 100 12 Yellow 000 255 0 100 13 3200 K Filter 000 255 0 100 14 Filters Speed 000 255 Fast slow 15 Gobo 1 000 009 010 019 020 028 029 038 039 047 048 057 058 067 068 077 078 087 088 097 098 107 108 117 118 127 128 189 190 193 194 255 Open white Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 1 shake Gobo 2 shake ...

Page 29: ...m 000 127 128 189 190 193 194 255 Gobo indexing CCW rotation fast slow Stop CW rotation slow fast 25 Iris 000 255 100 0 26 Frost 000 179 180 201 202 223 224 245 246 255 0 100 Open closed fast slow Closed open fast slow Frost Frost effect 27 Pan tilt Macro works with Channel 28 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 120 121 127 12...

Page 30: ...ro 9 Macro 10 Macro 11 Macro 12 31 Function 000 009 010 019 020 029 030 039 040 049 050 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 209 210 219 220 229 230 239 240 255 No function Auto focus enable Auto focus disable Fan speed auto Fan speed high No function Pan tilt move in black enable Pan tilt move in black disable Color move i...

Page 31: ...l alcohol and a soft lint free cotton cloth or a lens cleaning tissue Apply the solution directly to the cloth or tissue and drag any dirt and grime to the outside of the lens Gently polish the external glass surfaces until they are free of haze and lint When cleaning units with a movable mirror you should keep the contact with the mirror surface to a minimum to avoid scratching or damaging it Alw...

Page 32: ... not working Check fan Check fan wiring CPU B Error CPU C Error CPU D Error CPU E Error CPU F Error CPU G Error CPU H Error There is no communication with the indicated auxiliary CPU Check sensors wiring and position Check stepper motor belt and driver board Check control boards Pan Home Sensor Error Pan Encode Error Tilt Home Sensor Error Tilt Encode Error The moving head failed going to home pos...

Page 33: ...Defective or old lamp Replace lamp Temperature problems Check error messages and follow instructions Defective lamp wires or socket Repair change wiring or socket Defective ballast Replace ballast Circuit breaker fuse keeps tripping blowing Excessive circuit load Check total load placed on the electrical circuit Short circuit along the power wires Check for a short in the electrical wiring Fixture...

Page 34: ...ing will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace returned product s Claims The carrier is responsible for any damage incurred during shipping to this product or any part that shipped with it Therefore if the received merchandise appears to have damag...

Page 35: ... Cable boot N A Cord plugs Bare ended N A Light Source Type Power Quantity HID Lamp short arc 1200 W 1 Socket Lifespan PGJX50 750 50 failure Approved Lamps Phillips Osram GE MSR1200SA SE FastFit HTI 1500 W 60 P50 Lok It CSR 1200 SA TAL Head Movement Pan Range Tilt Range Fine Adjustment Option 0 540º 0 270º Yes Advanced Mode Gobos External Diameter Image Diameter Thickness 37 3 mm 30 0mm 5 mm Photo...

Page 36: ...CHAUVET 5200 NW 108th Avenue Sunrise FL 33351 USA 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Legend 1200E Spot User Manual Rev 03c October 2010 ...