LED Pinspot 360 User Manual
7
Rev. 2
The fuse is
located inside this
compartment.
Fuse Replacement
1.
With a flat head screwdriver wedge the fuse
holder out of its housing.
2.
Remove the damaged fuse from its holder and
replace with exact same type fuse.
3.
Insert the fuse holder back in its place and
reconnect power.
See the “Technical Specifications” section for the fuse size.
Power Linking
This fixture contains power linking via the edison outlet located next to the power input cable. Please
see the diagram below for further explanation.
The maximum quantity of fixtures that may be linked is 35.
The power linking shown in this document is for the Chauvet® North American version ONLY!
Therefore, it is the customer’s responsibility to check with the Dealer/Distributor regarding
power linking on the local version of the product. Connections and availability may change,
depending on the power requirements and/or regulations of each country/region.
Additional power
link out
Fixture 1
Fixture 2
Fixture 3
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.