background image

 
LED Pinspot 360 User Manual  

Rev. 2 

 The fuse is 
located inside this 
compartment. 

 

 

 

Fuse Replacement 

1. 

With a flat head screwdriver wedge the fuse 

holder out of its housing.  

2. 

Remove the damaged fuse from its holder and 

replace with exact same type fuse.  

3. 

Insert the fuse holder back in its place and 

reconnect power.  

 

See the “Technical Specifications” section for the fuse size. 

 

 

Power Linking 

This fixture contains power linking via the edison outlet located next to the power input cable. Please 
see the diagram below for further explanation. 
 
 

The maximum quantity of fixtures that may be linked is 35. 

 

 

 

 

 

 

 

 

 

 

 

 

 

The power linking shown in this document is for the Chauvet® North American version ONLY! 
Therefore, it is the customer’s responsibility to check with the Dealer/Distributor regarding 
power linking on the local version of the product. Connections and availability may change, 
depending on the power requirements and/or regulations of each country/region. 

Additional power 

link out 

Fixture 1 

Fixture 2 

Fixture 3 

Disconnect the power cord before replacing a fuse and always 
replace with the same type fuse. 

Summary of Contents for LED Pinspot 360

Page 1: ...U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com LED Pinspot 360 User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Page 2: ...CONS 3 SAFETY INSTRUCTIONS 4 2 INTRODUCTION 5 FEATURES 5 ADDITIONAL FEATURES 5 PRODUCT OVERVIEW 5 3 SETUP 5 AC POWER 6 LENS REPLACEMENT 6 FUSE REPLACEMENT 7 Power Linking 7 MOUNTING 8 Orientation 8 Rigging 8 4 OPERATING INSTRUCTIONS 9 CONFIGURING THE STARTING ADDRESS 9 DMX OPERATION 9 MASTER SLAVE 9 STANDALONE OPERATION 9 Automatic 9 Sound Active 9 Speed Adjustments Automatic Sound Active 10 DMX C...

Page 3: ...ls use the following conventions to differentiate certain types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A s...

Page 4: ...from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unski...

Page 5: ...Additional Features High power 3 W 700 mA LED Additional power output max 35 units Includes multiple lenses to change beam angles User selectable pan ranges 540 360 270 180 90 Built in automated programs via master slave with adjustable pan ranges Built in sound activated programs via master slave with adjustable pan ranges Product Overview Microphone sensitivity adjustment knob Tilt Adjustment Kn...

Page 6: ...listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Lens Replacement This fixture comes with an optional lens that modifies the beam angle Please see the instructions below for instructions on replacing the lens 1 Remove the retainer ring 2 Remove the lens the lens will fall out without the retai...

Page 7: ...ocated next to the power input cable Please see the diagram below for further explanation The maximum quantity of fixtures that may be linked is 35 The power linking shown in this document is for the Chauvet North American version ONLY Therefore it is the customer s responsibility to check with the Dealer Distributor regarding power linking on the local version of the product Connections and avail...

Page 8: ...lt or a hanging clamp When rigging consider routine maintenance and DIP switch access If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket adjustment knob Loosen the knob adjust to the desired angle and then tight...

Page 9: ...correct mode for this operation Master Setting Set the DIP switches for this fixture by using the below Standalone settings This automatically sets the fixture to Master Slave Setting Set the DIP switch 10 to the ON position It is not necessary to set the master fixture as the first fixture in the daisy chain It may be any fixture in the daisy chain For example fixture 2 5 10 or 12 etc Only 1 fixt...

Page 10: ...ent 6 8 OFF Combined fastest movement DMX Channel Values 5 CH Mode CHANNEL VALUE FUNCTION 1 000 255 Pan 0 540 2 000 255 Pan Speed Fast Slow 3 000 006 007 026 027 046 047 066 067 086 087 106 107 126 127 146 147 166 167 186 187 206 207 226 227 255 Auto Programs No Function Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Auto 6 Auto 7 Auto 8 Auto 9 Auto 10 Auto 11 Auto 12 4 000 008 009 126 127 191 192 254 255 255...

Page 11: ...xture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s Fed Ex packing or double boxing are recommended Note If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief d...

Page 12: ...hrs PHOTO OPTIC Luminance 1 m 6 lens installed 15 290 lux Luminance 1 m 9 lens included 5 550 lux Beam Angle installed 6 Beam Angle included 9 RANGE Pan 540 Tilt manual 330 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LED Pinspot 360 LEDPINSPOT360 WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us World Wide General Information CHAUVET 5200 NW 108th Avenue Sunr...

Reviews: