background image

LED Par 64-36VW B&C User Manual 

Rev. 4 

Safety Instructions 

 

 

 

 

Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that 
they also receive this instruction booklet. 

 

Always make sure that you are connecting to the proper voltage, and that the line voltage you are 
connecting to is not higher than that stated on the decal or rear panel of the fixture. 

 

This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. 

 

Make sure there are no flammable materials close to the unit while operating. 

 

The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent 
surfaces. Be sure that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or replacing fuse and be sure to replace with 
same fuse source. 

 

Secure fixture to fastening device using a safety chain. 

 

Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher 
than this.  

 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair the 
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 
contact the nearest authorized technical assistance center. 

 

Never connect the device to a dimmer pack. 

 

Make sure the power cord is never crimped or damaged. 

 

Never disconnect the power cord by pulling or tugging on the cord. 

 

Never carry the fixture directly from the cord. Always use the hanging/mounting bracket. 

 

Avoid direct eye exposure to the light source while it is on.  

2.

 

I

NTRODUCTION

 

Features 

 

2 or 4-channel DMX-512 variable white LED PAR can  

 

Operating modes: 

2-channel: warm white, cool white 
4-channel: warm white, cool white, strobe rate, dimmer 

Additional Features 

 

Built-in automated programs via master/slave with variable speed 

 

Built-in sound activated programs via master/slave  

 

Static color mixing without DMX controller 

 

Available in black or chrome 

 

High-power, 1 W, 350 mA LEDs 

 

Additional power output: max 8 units 

 

Double-bracket yoke doubles as floor stand 

 

Includes gel frame 

 

 

 

 

Please read these instructions carefully. It includes important 
information about the installation, usage and maintenance of this 
product. 

Summary of Contents for LED Par 64-36VWB

Page 1: ... A 800 762 1084 954 577 4455 FAX 954 929 5560 www chauvetlighting com LED Par 64 36VWB LED Par 64 36VWC User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable ...

Page 2: ... Features 4 PRODUCT OVERVIEW 5 PRODUCT OVERVIEW 6 3 SETUP 6 AC POWER 7 Power Linking 7 MOUNTING 8 Orientation 8 Rigging 8 4 OPERATING INSTRUCTIONS 9 CONFIGURING THE STARTING ADDRESS 9 CONTROL PANEL FUNCTIONS 9 MENU MAP 9 DMX OPERATION 10 MASTER SLAVE 10 STANDALONE OPERATION 10 Automatic 10 Sound Active 10 Preset Colors 10 Custom Static Color Mixing 11 DMX CHANNEL VALUES 11 4 CH 11 2 CH 11 SETTING ...

Page 3: ...entiate certain types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON ...

Page 4: ... this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Never connect the device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling...

Page 5: ...LED Par 64 36VW B C User Manual 5 Rev 4 Product Overview ...

Page 6: ...In Power Input Power Input Hardwired Microphone Audio Adjustment Knob Fuseholder Gel Frame Gel Frame Release Bracket Adjustment Knob Bracket Adjustment Knob Attachment Bolt not meant to be adjusted DMX Out Light Output Power Output Safety attachment point Hanging mounting 13 mm hole DIP switches ...

Page 7: ...o the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of fixtu...

Page 8: ...g clamp The hole in each bracket is 13 mm in size When rigging consider routine maintenance and control panel access Please see the following steps for installation Be sure to orient the gel frame release so that it is pointing up Please see the diagram below for a visual reference If the power link out is intended to be used with multiple fixture take into account the length of each power cable a...

Page 9: ...d layout of the control panel functions please see the menu map section on the following page Menu Map MAIN FUNCTION SUB FUNCTION SELECTION SUB SELECTION INSTRUCTION P P1 3 Color Switching Select between 1 switching and 1 fading auto programs Use S to modify the speed P2 3 Color fading P3 3 Color Switching Use the Audio Adjustment Knob located on the back of the fixture Sound Active program 2 CH d...

Page 10: ...xture in the daisy chain It may be any fixture in the daisy chain For example fixture 2 5 10 or 12 etc Only 1 fixture may be set to master Do not connect a DMX controller to the daisy chain for this operating mode Standalone Operation Automatic This fixture has preprogrammed chases These are accessed via the control panel and the speed may be adjusted for the chases Please see the instructions bel...

Page 11: ...resented by the following in the menu map r Warm White 000 100 C Cool White 000 100 DMX Channel Values 4 CH CHANNEL VALUE FUNCTION 1 000 ó 255 Master Dimmer Dimmer 0 100 2 000 ó 255 Warm White 2900K Dimmer 0 100 3 000 ó 255 Cool White 6300K Dimmer 0 100 4 000 ó 015 016 ó 255 Strobe No function Strobe 0 100 2 CH CHANNEL VALUE FUNCTION 1 000 ó 255 Warm White 2900K Dimmer 0 100 2 000 ó 255 Cool White...

Page 12: ... on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 m 1640 ft Maximum recommended number of fixtures on a serial data link 32 Tto use this fixture in a DMX or master slave operation you must daisy chain using DMX cables ...

Page 13: ...eneral Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure to powe...

Page 14: ...FedEx UPS packing or double boxing are recommended CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper th...

Page 15: ...lor Temperature Warm White 2900K Color Temperature Cool White 6300K PHOTO OPTIC Luminance 2 m 2 018 lux Beam Angle 23 Field Angle 47 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LED PAR 64 36VWB Black LEDPAR6436VWB LED PAR 64 36VWC Chrome LEDPAR6436VWC WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us World Wide General Information CHAUVET Lighting 5200 NW 108...

Reviews: