background image

  

 

 

Setup 

 

DMX-680 User Manual  

 

2006-10-10

/

18:04

 

Hanging Clamp 

Mounting 

O r i e n t a t i o n  

This fixture can be mounted on a truss using a clamp in any position or against a flat surface using 

the brackets provided. 

R i g g i n g  

The fixture includes two brackets with ¼ turn locks for attaching a 

standard truss mounting hanging clamp. You must supply your own 

clamp and make sure the clamp is capable of supporting the weight 

of this fixture. You can order C-clamps from any CHAUVET dealer 

or distributor. 

1. 

Block access below the work area and use suitable and 
stable platform when installing or servicing fixture. 

2. 

Align the clamp screw with the center hole on the yoke and 
tighten. 

3. 

Verify the structure can hold 10 times the weight of all to-be 
installed fixtures. 

4. 

Adjust the angle on the yoke arm as necessary. 

5. 

Always use a safety cable or chain as a secondary source of 
attachment. The safety cable must hold 10 times the weight 
of the fixture. If safety cable attachment point is provided 
that is permanently affixed to the surface or body of the 
fixture, use that instead of looping through a hanging 
yoke/arm. 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller 

or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The 

combined number of channels required by all the fixtures on a serial data link determines the number 

of fixtures the data link can support.  

The DMX-680 fixtures use 7 channels of DMX control. 

Important:  Fixtures on a serial data link must be daisy chained in one single line. To comply with 
the EIA-485 standard no more than 32 devices should be connected on one data link. Connecting 
more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may 
result in deterioration of the digital DMX signal.  

Maximum recommended serial data link distance: 500 meters (1640 ft.) 

Maximum recommended number of fixtures on a serial data link: 32 fixtures 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX 

cables directly from a dealer/distributor or construct your own cable. If you choose to create your own 

cable please use data-grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.  

Summary of Contents for Intimidator Spot DMX-680

Page 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 10 10 18 04 DMX 680 USER MANUAL ...

Page 2: ...INKING 8 Data Cabling 8 DMX Data Cable 9 Cable Connectors 9 3 Pin to 5 Pin Conversion Chart 9 SETTING UP A DMX SERIAL DATA LINK 10 STANDALONE MASTER SLAVE FIXTURE LINKING 10 4 OPERATING INSTRUCTIONS 11 NAVIGATING THE CONTROL PANEL 11 CONTROL OPERATING MODE N O D E 11 DMX Mode N dN 11 Stand Alone Master Slave N So N SL N Au 12 DMX ADDRESSING A D D R 12 USER CONFIGURATIONS 13 Individual Pan Tilt Rev...

Page 3: ...at the fixture be returned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x Intimidator Spot DMX 680 1 x ELC 24v 250w lamp 1 x Power cable 2 x brackets Warranty Card Users Manual Contact U...

Page 4: ...Using the wrong type of lamp in this product VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Mainta...

Page 5: ... Blackout reset sound activation and built in automatic programs via DMX Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX Additional Features Dual hanging brackets with turn fasteners Compact and lightweight LED display menu with invert Pan tilt invert option Micro stepping motors Thermal switch fan cooled DMX Channel Summary Channel Fun...

Page 6: ... 2006 10 10 18 04 DMX Output Power cable DMX Input Fuse Compartment Clamp brackets with turn locks Rubber feet Green LED DMX Signal Indicator Focusing lens gun Carrying Handles Projector Head LED Control Panel Yoke Arm Product Overview ...

Page 7: ...to circuits with a suitable Earth Ground Power Cable Configuration CABLE Pin International Screw Color BROWN Live L Yellow or Brass BLUE Neutral N Silver YELLOW GREEN Earth EG Ground Green Lamp Installation You will need to install a lamp prior to the initial operation of the fixture Warning When replacing the lamp please wait 15 minutes after powering down to allow the unit to cool down Always di...

Page 8: ...ad of looping through a hanging yoke arm Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support The DMX...

Page 9: ...mon can cause a ground loop and your fixture to perform erratically Test cables with OHM meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 Pin to 5 Pin Conversion Chart Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter CHAUVET Model No DMX5M The chart below details a proper...

Page 10: ...e to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to the input of the following fixture and so on CHAUVET Certified DMX Data Cables Order Code Description D...

Page 11: ...nu options Press the Enter button to access the menu function currently displayed or to enable a menu option To return to the previous option or menu without changing the value press the Fun button Control Operating Mode N o d E The DMX 680 has four control or operating modes that must be defined in each fixture in order to work correctly under stand alone master slave or manual DMX control Please...

Page 12: ...ode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Ch...

Page 13: ...ilt of all fixtures at the same time you will notice that the fixtures whose orientation is different from the others will most likely move opposite of the rest You can apply a pan and tilt Invert by following the settings in the table below MENU LEVEL 1 OPTION LEVEL 2 DESCRIPTION Standard Pan Movement Normal left to right Reverse Pan Movement Inverted movement from right to left Standard Tilt Mov...

Page 14: ...ting of the Tilt movement Pan Testing of the Pan movement Color Tests the color wheel Gobo Tests the gobo wheel Shutter Tests the shutter Reverse the segment display d S P L You can rotate the display 180 so that it becomes easier to read when the fixture is positioned upside down MENU OPTION DESCRIPTION Standard Standard display orientation Reverse Rotated display orientation Fixture reset r E S ...

Page 15: ...sitive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be p...

Page 16: ...Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days DMX Channel Values CHANNEL VALUE FUNCTION 1 000 Ù 127 128 Ù 179 180 Ù 223 224 Ù 250 251 Ù 255 Control Operating Mode DMX Mode Stand alone automatic Stand alone sound active Lamp turn on after 10 seconds Lamp shut...

Page 17: ...2 and on Stand Alone mode running at an automatic preset speed Standard pan movement Reverse pan movement Standard tilt movement Reverse tilt movement Combined control of pan tilt standard default Combined control of pan tilt reversed settings Tests all motors in the fixture Provides testing of the pan movement Provides testing of the tilt movement Provides testing of the color wheel Provides test...

Page 18: ...m Angle 11 Pan 510 Tilt 260 Illuminance 2 330fc or 25 070lux 1 meter FUSE Main 20mm Glass 7A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 7 ORDERING INFORMATION Intimidator Spot DMX 680 Technical Support Address Service Dept 3000 N 29th Ct Holly...