background image

 
Page 7 of 17 

Intimidator Scan LED 300 User Manual (Rev. 3) 

3.

 

S

ETUP

 

 

 

AC Power 

 

 

 

This fixture is switchable and runs on either 115 VAC, 60 Hz or 230 VAC, 50 Hz power. Before 

powering on the unit, make sure the line voltage to which you are connecting it matches the 

current setting on the voltage selection switch. 

 

To determine the power requirements for a particular fixture, see the label affixed to the back 

plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating 

indicates its average current draw under normal conditions.  

 

 

 

Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only 

as a 0 to 100% switch.

 

 

 

 

Always connect the fixture to a circuit with a suitable electrical ground.  

 

 

Power Linking 

 

 

 

This fixture contains power linking via the Edison outlet located in front of the power input cable. 

Please see the diagram below for further explanation. 

 

 

 

The maximum quantity of Intimidator™ Scan LED 300 that may be linked is 4. 

 

 

 

 

 

 

 

The power linking shown in this document is for the CHAUVET® North American version 
ONLY! Therefore, it is the customer’s responsibility to check with the Dealer/Distributor 
regarding power linking on the local version of the product. Connections and availability 
may change, depending on the power requirements and/or regulations of each 
country/region. 

 
 

 

Additional power 

link out 

Summary of Contents for Intimidator Barrel LED 300

Page 1: ...User Manual...

Page 2: ...igging 8 4 OPERATING INSTRUCTIONS 9 USING THE CONTROL PANEL 9 MENU MAP 9 CONFIGURING THE STARTING ADDRESS 9 OPERATION 10 DMX Operation 10 Master Slave Mode Sound Active Auto Mode 10 Automatic Slow 10...

Page 3: ...ion from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one ca...

Page 4: ...disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 1...

Page 5: ...Page 5 of 17 Intimidator Scan LED 300 User Manual Rev 3 2 INTRODUCTION Product Dimensions...

Page 6: ...Page 6 of 17 Intimidator Scan LED 300 User Manual Rev 3 Product Overview Bracket Adjustment Knob DMX In DMX Out Power Out Fuseholder Power In Voltage Selection Switch 115 230 VAC Safety...

Page 7: ...he fixture to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical...

Page 8: ...ake into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket yoke adjustment knob s Loose...

Page 9: ...tandalone Slave receive mode NStS SrUn Standalone Slow NAFA FASt Standalone Sound active Pan Invert PAN rPAN Pan invert Tilt Invert tit rtit Tilt invert Display Invert diS rdiS Invert the display DMX...

Page 10: ...the master Master The master fixture may be set in any of the STANDALONE modes sound active fast or slow Slave 1 Press MODE ESC until NASL appears on the LED screen 2 Using UP and DOWN select SLAu 3...

Page 11: ...The purpose of this menu is to adjust the home position electronic adjustment of the attributes listed below MAIN FUNCTION SELECTION INSTRUCTION P128 000 255 Adjustment for pan t128 000 255 Adjustment...

Page 12: ...nction Pan tilt move in black Pan tilt move in black disable Color wheel move in black Color wheel move in black disabled Gobo wheel move in black Gobo wheel move in black disabled No Function All mov...

Page 13: ...ow blue split colors Blue Kelly split colors Kelly red split colors Red dark blue split colors Dark blue white split colors Rotate clockwise slow fast Rotate counter clockwise slow fast 7 000 003 004...

Page 14: ...it addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interfa...

Page 15: ...ast every 20 days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be se...

Page 16: ...utput 4 units max LIGHT SOURCE Type high power single source LED Quantity 1 white Rating red green blue 60 W 14 9 A 50 000 hrs PHOTO OPTIC Lux 9 650 1 m Beam angle 21 INDOOR OUTDOOR Rating For indoor...

Page 17: ...NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Att...