background image

 
 
 
 

Page 16 of 16 

Hurricane™ Haze 3D User Manual Rev. 1 

Returns 

To return a product or request support: 

 

In the U.S., contact Chauvet World Headquarters. 

 

In the UK or Ireland, contact Chauvet Europe Ltd. 

 

In Mexico, contact Chauvet Mexico. 

 

In any other country, DO NOT contact Chauvet. Contact your distributor. See 

www.chauvetlighting.com

 for 

distributors outside the U.S., United Kingdom, Ireland, or Mexico. 

 

If you live outside the U.S., United Kingdom, Ireland, or Mexico, contact your distributor of record and follow 

their instructions on how to return Chauvet products to them. Visit our website for contact details. 

 

Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) 
number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of 
the cause for the return. 
You must send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will 
not issue call tags.  
Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number. 

 

Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box. 

 

Before sending the product, clearly write the following information on a piece of paper and place it inside the box: 

 

Your name 

 

Your address 

 

Your phone number 

 

RMA number 

 

A brief description of the problem 

Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your 
responsibility. FedEx packing or double-boxing is recommended. 

 

Chauvet reserves the right to use its own discretion to repair or replace returned product(s). 

 
 
 

Contact 
Us 

WORLD HEADQUARTERS

 - Chauvet 

General Information 

 

Address:  

5200 NW 108th Avenue 

 

 

 

Sunrise, FL 33351 

 

Voice: 

 

(954) 577-4455 

 

Fax: 

 

(954) 929-5560 

 

Toll free:  

(800) 762-1084 

Technical Support 

 

Voice: 

(954) 577-4455 (Press 4) 

 

Fax:  

(954) 756-8015 

 

Email: 

[email protected] 

 

World Wide Web 

www.chauvetlighting.com

 

 

UNITED KINGDOM AND IRELAND

 - Chauvet Europe Ltd. 

General Information 

 

Address:  

Unit 1C 

 

 

 

Brookhill Road Industrial Estate 

 

 

 

Pinxton, Nottingham, UK 

 

 

 

NG16 6NT 

 

Voice: 

 

+44 (0)1773 511115 

 

Fax: 

 

+44 (0)1773 511110 

Technical Support 

 

Email: 

[email protected]

 

 

World Wide Web 

www.chauvetlighting.co.uk

 

 

MEXICO

 - Chauvet Mexico

 

General Information 

 

Address:  

Av. Santa Ana 30 

 

 

 

Parque Industrial Lerma 

 

 

 

Lerma, Mexico C.P. 52000 

 

Voice: 

 

+52 (728) 285-5000 

Technical Support 

 

Email:  

[email protected]

 

 

World Wide Web 

www.chauvet.com.mx

 

 

Outside the U.S., United Kingdom, Ireland, or Mexico, contact your dealer. Follow their instructions to request 
support or to return a product. Visit our website for contact details. 

 

Summary of Contents for Hurricane Haze 3D

Page 1: ...User Manual ...

Page 2: ...oduct Dimensions 6 3 Setup 7 AC Power 7 Fuse Replacement 7 Mounting 8 Orientation 8 Rigging 8 4 Operation 10 Control Panel Operation 10 Fluid Tank Indicator LEDs 10 Menu Map 10 HC T Wired Timer Remote Operation 11 Configuration Standalone Mode 12 Manual Mode 12 Configuration DMX 12 Starting Address 12 DMX Channel Assignments and Values 12 2 CH 12 5 Technical Information 13 General Maintenance 13 S...

Page 3: ...on Meaning Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status Menu Settings A sequence of menu options to be followed ON A value to be entered or selected Symbols Convention Meaning Critical installation configuration or ...

Page 4: ...this User Manual for future consultation If you sell this product to another user be sure that they also receive this document This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture Make sure there are no flammable materials close to the unit while operating Always install this product in a location with adequate ventilation at least 20 ...

Page 5: ...on Product Overview Wired Remote Controller Socket Power In Power Switch Fluid Level Indicator Access Door and Storage Compartment for the HC T DMX In Out Fuse Holder Internal Fluid Tank Indicator Lights Digital Control Panel Display and Menu Buttons Safety Loop ...

Page 6: ...Page 6 of 16 Hurricane Haze 3D User Manual Rev 1 Product Dimensions 15 in 380 mm 13 4 in 340 mm 12 9 in 328 mm ...

Page 7: ...round to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement Disconnect this product from the power outlet before replacing the fuse 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 3...

Page 8: ...gging point whether an elevated platform or a truss When rigging this product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When mounting this product overhead always use a safety cable Never mount directly above people as condensation may drip and fluid may be hot Before deciding on a location for thi...

Page 9: ...ricane Haze 3D User Manual Rev 1 Page 9 of 16 Mounting Diagram Bracket Adjustment Knob 2 Mounting Bracket Mounting Clamp such as CLP 15N clamp from Chauvet Safety Cable Rubber Feet for floor mounting 15 15 ...

Page 10: ... level Examples If using the digital control panel and afterwards you connect a DMX controller to the product then the DMX controller will take priority control If using the remote controller and the digital control panel is used next then the digital control panel will take priority control Fluid Tank Indicator LEDs Indicator LEDs show the status of the fill tank as follows Red the fluid tank is ...

Page 11: ...and OUTPUT adjustment knobs to the desired positions INTERVAL knob sets the amount of time in between bursts of haze DURATION knob sets the length of time that the haze machine will run during the burst OUTPUT knob adjusts the haze output 5 Press the CONTINUOUS latching button and the haze machine outputs haze until the button is pressed again The Manual Power LED Indicator above the button will l...

Page 12: ...X controller 1 Connect this product to a suitable power outlet 2 Turn this product on 3 Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product Starting Address The Hurricane Haze 3D has one DMX personality a 2 channel mode for basic control The Hurricane Haze 3D uses up to two channels in its 2 channel DMX mode which defines the highest configurable a...

Page 13: ...mp to run dry 6 Refill with haze fluid to continue using the hazer Run the machine briefly to clear any remaining cleaning solution from the pump and heater Note Do not operate the machine without fluid at any time Fog Cleaner Quart FCQ was specifically developed by Chauvet to clean your Hurricane Haze 3D Make sure you use FCQ regularly to increase the life of your product Storage Before storing t...

Page 14: ...l cables are not DMX compatible Replace non DMX cables with true DMX cables Interference with AC or radio signals Keep DMX cables away from AC wires or radio equipment DMX cable too long Use a shorter DMX cable or install an optically coupled DMX amplifier right before the product with intermittent problems Terminator not connected Install a terminator False Sensor Reading Priming Air bubbles in f...

Page 15: ...rating current 11 A 6 2 A Fuse size F 13 A 250 V F 7 A 250 V Power I O US Canada UK Worldwide Power input connector IEC IEC Power cord plug Edison Local plug Operation Heat up Time Tank Capacity Fluid Consumption 4 min 0 7 gal 2 5 l 14 ml min Misc Output 1 700 cfm Approved Fluids CHAUVET DJ Haze Fluid Gallon High Performance Haze Fluid HFG Premium Haze Fluid PHF Thermal Maximum External Temp Cooli...

Page 16: ...duct clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility FedEx packing or double boxing is recommended Chauvet reserves the right to use its own discretion ...

Reviews: