![Chauvet HIVE Quick Reference Manual Download Page 5](http://html.mh-extra.com/html/chauvet/hive/hive_quick-reference-manual_2593053005.webp)
EN
HIVE™ QRG
5
Menu Options
Main Level
Programming Levels
Description
Addr
001–512
Sets the DMX starting address
CHnd
3CH
3-channel mode
20CH
20-channel mode
SLnd
SL 0
Slave mode 0
SL 1
Slave mode 1
AUto
rUn
Auto program
CoLo
rEd
0–255
Red (0–100%)
GrEE
0–255
Green (0–100%)
bLUE
0–255
Blue (0–100%)
So1
Strobe, slow speed
So2
Strobe, medium speed
So3
Strobe, fast speed
LEd
on
LED background light on
oFF
LED background light off
dISP
dISP
Normal display
dSIP
Inverted display
VEr
Shows currently installed software version
DMX Linking
The HIVE™ can work with a DMX controller when linked by DMX serial
connections. Instructions for connecting and configuring this product for
DMX operation are in the User Manual. If you are not familiar with DMX,
download the DMX Primer from
www.chauvetlighting.com
.
Starting Address
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is
493
.
Master/Slave
Connection
The HIVE™ uses the DMX data connection for its Master/Slave mode.
Instructions for connecting and configuring this product for Master/Slave
operation are in the User Manual.